{"product_id":"accutab-powerbase-3070-tablet-chlorination-system-w-1-5hp-hayward-pump-csa","title":"AccuTab Powerbase 3070 Tablet Chlorination System w\/ 1.5HP Hayward Pump,CSA","description":"\u003cp data-path-to-node=\"0\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003eAccu-Tab PowerBase 3070 Tablet Chlorination System w\/ 1.5 HP Hayward Booster Pump (CSA Certified)\u003c\/b\u003e\u003cspan\u003e is a high-capacity,\u003c\/span\u003e\u003cspan\u003e commercial-grade calcium hypochlorite (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"Ca(OCl)_2\" data-index-in-node=\"161\"\u003e$Ca(OCl)_2$\u003c\/span\u003e\u003cspan\u003e) erosion feeder engineered by Westlake Water Solutions (Axiall\/PPG) for high-load commercial aquatic centers,\u003c\/span\u003e\u003cspan\u003e municipal waterparks,\u003c\/span\u003e\u003cspan\u003e surf lagoons,\u003c\/span\u003e\u003cspan\u003e and multi-pool complexes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\"\u003e\u003cspan\u003eConfigured with a \u003c\/span\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"18\"\u003e70 lb dry-tablet hopper\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e an integrated dual-float chemical solution reservoir,\u003c\/span\u003e\u003cspan\u003e and a dedicated \u003c\/span\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"113\"\u003e1.5 HP Hayward centrifugal booster pump\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e the 3070 system provides over double the tablet capacity and chemical delivery volume of the smaller 1030 unit.\u003c\/span\u003e\u003cspan\u003e It automates high-volume sanitization while avoiding the bulk storage footprint,\u003c\/span\u003e\u003cspan\u003e product degradation,\u003c\/span\u003e\u003cspan\u003e and severe off-gassing issues associated with commercial liquid sodium hypochlorite bulk tanks.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eOperating Principle \u0026amp; Controlled Erosion Dynamics\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eControlled Bottom-Layer Erosion:\u003c\/b\u003e\u003cspan\u003e Dry 3-1\/8\" Accu-Tab tablets are supported inside the hopper above an engineered,\u003c\/span\u003e\u003cspan\u003e multi-port erosion sieve plate.\u003c\/span\u003e\u003cspan\u003e Water delivered by the inlet float assembly contacts \u003c\/span\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"199\"\u003eonly the bottom layer of tablets\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cspan\u003e The bulk dry tablet column above remains completely isolated from moisture,\u003c\/span\u003e\u003cspan\u003e eliminating tablet mushing,\u003c\/span\u003e\u003cspan\u003e wicking,\u003c\/span\u003e\u003cspan\u003e bridging,\u003c\/span\u003e\u003cspan\u003e and chemical concentration spikes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eDual-Chamber Solution Mixing Basin:\u003c\/b\u003e\u003cspan\u003e Dissolved calcium hypochlorite drains by gravity through the sieve grid directly into an integrated high-density polyethylene solution holding tank equipped with internal baffles to ensure consistent solution concentration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003e1.5 HP Centrifugal Booster Injection:\u003c\/b\u003e\u003cspan\u003e A high-head \u003c\/span\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"50\"\u003e1.5 HP Hayward commercial centrifugal pump\u003c\/b\u003e\u003cspan\u003e draws concentrated chlorine solution from the holding reservoir and injects it downstream into high-flow filtration return loops against elevated line pressures up to \u003c\/span\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"260\"\u003e40+ PSI\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eIntegrated Safety \u0026amp; Float Interlocks:\u003c\/b\u003e\u003cspan\u003e Equipped with redundant high-level and low-level magnetic reed float switches wired to an internal motor contactor.\u003c\/span\u003e\u003cspan\u003e The system cuts power to the booster pump on low solution level (preventing dry-run seal damage) and isolates the water inlet on high level (preventing mechanical room flooding).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eTablet Storage Capacity:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"25\"\u003e70 lbs (31.8 kg)\u003c\/b\u003e\u003cspan\u003e dry tablet hopper capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eMaximum Chlorine Delivery Rate:\u003c\/b\u003e\u003cspan\u003e Up to \u003c\/span\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"38\"\u003e6.0 to 7.0 lbs\/hr\u003c\/b\u003e\u003cspan\u003e available chlorine gas equivalent (~2.\u003c\/span\u003e\u003cspan\u003e7 to 3.\u003c\/span\u003e\u003cspan\u003e2 kg\/hr) under NSF Standard 50 test parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eFacility Sizing Guidelines:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"7,2,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,1,0,0\"\u003e\u003cb data-path-to-node=\"7,2,1,0,0\" data-index-in-node=\"0\"\u003eIndoor Commercial Pools:\u003c\/b\u003e\u003cspan\u003e Up to \u003c\/span\u003e\u003cb data-path-to-node=\"7,2,1,0,0\" data-index-in-node=\"31\"\u003e1,000,000 US Gallons\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 3,\u003c\/span\u003e\u003cspan\u003e785,\u003c\/span\u003e\u003cspan\u003e000 L).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,1,1,0\"\u003e\u003cb data-path-to-node=\"7,2,1,1,0\" data-index-in-node=\"0\"\u003eOutdoor Stabilized Pools (CYA 15–30 ppm):\u003c\/b\u003e\u003cspan\u003e Up to \u003c\/span\u003e\u003cb data-path-to-node=\"7,2,1,1,0\" data-index-in-node=\"48\"\u003e350,000 to 400,000 US Gallons\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 1,\u003c\/span\u003e\u003cspan\u003e325,\u003c\/span\u003e\u003cspan\u003e000 to 1,\u003c\/span\u003e\u003cspan\u003e514,\u003c\/span\u003e\u003cspan\u003e000 L).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,1,2,0\"\u003e\u003cb data-path-to-node=\"7,2,1,2,0\" data-index-in-node=\"0\"\u003eOutdoor High-Load Waterparks \/ Wave Pools:\u003c\/b\u003e\u003cspan\u003e Up to \u003c\/span\u003e\u003cb data-path-to-node=\"7,2,1,2,0\" data-index-in-node=\"49\"\u003e150,000 to 200,000 US Gallons\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 568,\u003c\/span\u003e\u003cspan\u003e000 to 757,\u003c\/span\u003e\u003cspan\u003e000 L).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eBooster Pump Specification:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"28\"\u003e1.5 HP Hayward Centrifugal Pump\u003c\/b\u003e\u003cspan\u003e (commercial closed-impeller wet end,\u003c\/span\u003e\u003cspan\u003e NEMA 56J face motor).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eHydraulic Connections:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"7,4,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,1,0,0\"\u003e\u003cb data-path-to-node=\"7,4,1,0,0\" data-index-in-node=\"0\"\u003eInlet (Water Supply):\u003c\/b\u003e\u003cspan\u003e 1\" Schedule 80 PVC Slip \/ Socket (regulated incoming supply:\u003c\/span\u003e\u003cspan\u003e 15–20 PSI).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,1,1,0\"\u003e\u003cb data-path-to-node=\"7,4,1,1,0\" data-index-in-node=\"0\"\u003eOutlet (Discharge\/Injection):\u003c\/b\u003e\u003cspan\u003e 1-1\/4\" or 1-1\/2\" Schedule 80 PVC Slip \/ Socket with included union check valve,\u003c\/span\u003e\u003cspan\u003e manual flow throttle valve,\u003c\/span\u003e\u003cspan\u003e and inline flow indicator.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eElectrical Specifications \u0026amp; Approvals:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"7,5,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,1,0,0\"\u003e\u003cb data-path-to-node=\"7,5,1,0,0\" data-index-in-node=\"0\"\u003ePrimary Power Supply:\u003c\/b\u003e\u003cspan\u003e 120V \/ 240V AC (field-switchable),\u003c\/span\u003e\u003cspan\u003e 60 Hz,\u003c\/span\u003e\u003cspan\u003e 1-Phase,\u003c\/span\u003e\u003cspan\u003e 20 Amp dedicated circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,1,1,0\"\u003e\u003cb data-path-to-node=\"7,5,1,1,0\" data-index-in-node=\"0\"\u003eExternal Controller Trigger:\u003c\/b\u003e\u003cspan\u003e 120V AC switched signal from Pool Link 500\/1000 Series ORP \/ Free Chlorine relays.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,1,2,0\"\u003e\u003cb data-path-to-node=\"7,5,1,2,0\" data-index-in-node=\"0\"\u003eCertifications:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"7,5,1,2,0\" data-index-in-node=\"16\"\u003eCSA Certified\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e NSF\/ANSI Standard 50 commercial listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,6,0\"\u003e\u003cb data-path-to-node=\"7,6,0\" data-index-in-node=\"0\"\u003eOverall Dimensions:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"7,6,0\" data-index-in-node=\"20\"\u003e32.0\" W × 24.5\" D × 43.5\" H\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 81.\u003c\/span\u003e\u003cspan\u003e3 cm W × 62.\u003c\/span\u003e\u003cspan\u003e2 cm D × 110.\u003c\/span\u003e\u003cspan\u003e5 cm H).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eConsumable Tablet Specification\u003c\/h3\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eSpecified Chemistry:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"21\"\u003eAccu-Tab Blue SI 3-1\/8\" Calcium Hypochlorite Tablets\u003c\/b\u003e\u003cspan\u003e (68% nominal \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"Ca(OCl)_2\" data-index-in-node=\"87\"\u003e$Ca(OCl)_2$\u003c\/span\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e 65% minimum available chlorine).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eScale Inhibitor Chemistry (SI):\u003c\/b\u003e\u003cspan\u003e Pre-blended with a proprietary polyphosphate scale-inhibiting matrix designed to sequester calcium ions directly at the dissolution interface,\u003c\/span\u003e\u003cspan\u003e preventing calcium carbonate (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"CaCO_3\" data-index-in-node=\"205\"\u003e$CaCO_3$\u003c\/span\u003e\u003cspan\u003e) scaling inside the sieve plate,\u003c\/span\u003e\u003cspan\u003e piping,\u003c\/span\u003e\u003cspan\u003e check valves,\u003c\/span\u003e\u003cspan\u003e and pump impeller.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eCritical Chemical Precaution:\u003c\/b\u003e\u003cspan\u003e Never load trichlor,\u003c\/span\u003e\u003cspan\u003e dichlor,\u003c\/span\u003e\u003cspan\u003e calcium chloride,\u003c\/span\u003e\u003cspan\u003e or organic stabilized tablets into the 3070 hopper.\u003c\/span\u003e\u003cspan\u003e Mixing chemical types will trigger rapid exothermic decomposition,\u003c\/span\u003e\u003cspan\u003e violent gas generation,\u003c\/span\u003e\u003cspan\u003e and catastrophic explosion risk.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"12\"\u003eInstallation Architecture \u0026amp; Pool Link Integration\u003c\/h3\u003e\n\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cdiv class=\"code-block ng-tns-c493897606-105 ng-animate-disabled ng-trigger ng-trigger-codeBlockRevealAnimation\" data-hveid=\"3\"\u003e\n\u003c!----\u003e\n\u003cdiv class=\"formatted-code-block-internal-container ng-tns-c493897606-105\"\u003e\n\u003cdiv class=\"animated-opacity ng-tns-c493897606-105\"\u003e\n\u003c!----\u003e\n\u003cpre class=\"ng-tns-c493897606-105\"\u003e\u003ccode role=\"text\" data-test-id=\"code-content\" class=\"code-container formatted ng-tns-c493897606-105 no-decoration-radius\"\u003e                 Pool Recirculation Loop (Post-Filter)\n                             │\n            ┌────────────────┴────────────────┐\n            │                                 │\n            ▼                                 ▼\n      [Shut-off Valve]                  [Shut-off Valve]\n            │                                 ▲\n            ▼                                 │\n  [Inlet Pressure Regulator]          [Discharge Check Valve]\n     (Set to 15-20 PSI)                       ▲\n            │                                 │\n            ▼                          [Throttling Valve]\n  ┌───────────────────────────────────────────┴───────────────────┐\n  │  Accu-Tab PowerBase 3070 Base Unit                            │\n  │                                                               │\n  │  [70 lb Tablet Hopper] ──\u0026gt; [Erosion Sieve Plate]              │\n  │                                   │                           │\n  │                                   ▼                           │\n  │  [Inlet Float Valve]   ──\u0026gt; [Solution Holding Basin]           │\n  │                                   │                           │\n  │                                   ▼                           │\n  │  [Low\/High Level Floats] ──\u0026gt; [1.5 HP Hayward Booster Pump]    │\n  └───────────────────────────────────────────────────────────────┘\n\u003c\/code\u003e\u003c\/pre\u003e\n\u003c!----\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003col start=\"1\" data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eSupply Water Source:\u003c\/b\u003e\u003cspan\u003e Tap supply water downstream of pool filtration media (clean water) but upstream of any acid injection ports or heaters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eBackpressure Sizing:\u003c\/b\u003e\u003cspan\u003e The 1.\u003c\/span\u003e\u003cspan\u003e5 HP booster produces significant discharge head; ensure discharge injection quills enter the center of the recirculating main pipe and are rated for full loop hydraulic pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003ePool Link Control Setup:\u003c\/b\u003e\u003cspan\u003e Connect the 3070 control pigtail to the Pool Link 500\/1000 primary sanitizer feed circuit.\u003c\/span\u003e\u003cspan\u003e Set the controller's feed safety interlock timer to a 20-minute maximum run limit to protect against ORP probe lag or sample flow interruption.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":68030052565103,"sku":"9501119-HP-CSA","price":13306.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/Accu-Tab1030.webp?v=1793117712","url":"https:\/\/commercialpoolandspasupplies.com\/products\/accutab-powerbase-3070-tablet-chlorination-system-w-1-5hp-hayward-pump-csa","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}