{"product_id":"accutab-powerbase-3500-tablet-chlorination-system-w-1-5hp-hayward-pump-csa","title":"AccuTab Powerbase 3500 Tablet Chlorination System w\/ 1.5HP Hayward Pump,CSA","description":"\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003eAccu-Tab PowerBase 3500 Tablet Chlorination System w\/ 1.5 HP Hayward Booster Pump (CSA Certified)\u003c\/b\u003e\u003cspan\u003e is the flagship high-capacity,\u003c\/span\u003e\u003cspan\u003e commercial-grade calcium hypochlorite (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"Ca(OCl)_2\" data-index-in-node=\"172\"\u003e$Ca(OCl)_2$\u003c\/span\u003e\u003cspan\u003e) erosion feeder manufactured by Westlake Water Solutions (Axiall\/PPG).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\"\u003e\u003cspan\u003eEngineered for massive aquatic applications—including Olympic competition complexes,\u003c\/span\u003e\u003cspan\u003e high-volume outdoor waterparks,\u003c\/span\u003e\u003cspan\u003e large surf lagoons,\u003c\/span\u003e\u003cspan\u003e and municipal potable water or wastewater treatment plants—the 3500 system features a massive \u003c\/span\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"231\"\u003e500 lb dry-tablet hopper\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e an oversized internal solution mixing basin,\u003c\/span\u003e\u003cspan\u003e and a heavy-duty \u003c\/span\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"319\"\u003e1.5 HP Hayward commercial centrifugal booster pump\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cspan\u003e It is designed to handle extreme chlorine demand while minimizing operator handling and refill frequency.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eOperating Principle \u0026amp; Controlled Erosion Dynamics\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eControlled Bottom-Layer Erosion Technology:\u003c\/b\u003e\u003cspan\u003e Despite housing up to 500 lbs of dry chemical,\u003c\/span\u003e\u003cspan\u003e only the lowest layer of 3-1\/8\" Accu-Tab tablets contacts the side-stream dissolution water flowing over the sieve plate.\u003c\/span\u003e\u003cspan\u003e The dry tablet column above remains isolated from moisture and humidity,\u003c\/span\u003e\u003cspan\u003e preventing wicking,\u003c\/span\u003e\u003cspan\u003e softening,\u003c\/span\u003e\u003cspan\u003e bridging,\u003c\/span\u003e\u003cspan\u003e or chemical concentration spikes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eContinuous Heavy-Duty Solution Basin:\u003c\/b\u003e\u003cspan\u003e Gravity directs dissolved calcium hypochlorite solution through the erosion grid into an integrated,\u003c\/span\u003e\u003cspan\u003e heavy-duty polyethylene reservoir.\u003c\/span\u003e\u003cspan\u003e Internal baffling promotes uniform dissolution concentration across high-throughput delivery cycles.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003e1.5 HP Commercial Booster Injection:\u003c\/b\u003e\u003cspan\u003e The close-coupled \u003c\/span\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"55\"\u003e1.5 HP Hayward centrifugal pump\u003c\/b\u003e\u003cspan\u003e draws concentrated chlorine solution from the holding reservoir and delivers it directly into high-pressure,\u003c\/span\u003e\u003cspan\u003e high-volume pool recirculation mains against line pressures exceeding \u003c\/span\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"266\"\u003e40 PSI\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eFailsafe Mechanical \u0026amp; Electrical Interlocks:\u003c\/b\u003e\u003cspan\u003e Equipped with factory-integrated high- and low-level magnetic reed float switches wired to an internal motor contactor.\u003c\/span\u003e\u003cspan\u003e The system cuts pump operation on low solution level (preventing dry-run seal burnout) and isolates incoming water on high level (preventing overflow).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eTablet Storage Capacity:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"25\"\u003e500 lbs (226.8 kg)\u003c\/b\u003e\u003cspan\u003e dry tablet hopper capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eMaximum Chlorine Delivery Rate:\u003c\/b\u003e\u003cspan\u003e Up to \u003c\/span\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"38\"\u003e25.0 lbs\/hr\u003c\/b\u003e\u003cspan\u003e of available chlorine gas equivalent (~11.\u003c\/span\u003e\u003cspan\u003e3 kg\/hr) under NSF Standard 50 test parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eFacility Sizing Guidelines:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"7,2,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,1,0,0\"\u003e\u003cb data-path-to-node=\"7,2,1,0,0\" data-index-in-node=\"0\"\u003eIndoor Aquatic Complexes:\u003c\/b\u003e\u003cspan\u003e Pools exceeding \u003c\/span\u003e\u003cb data-path-to-node=\"7,2,1,0,0\" data-index-in-node=\"42\"\u003e2,500,000+ US Gallons\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 9,\u003c\/span\u003e\u003cspan\u003e460,\u003c\/span\u003e\u003cspan\u003e000+ L).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,1,1,0\"\u003e\u003cb data-path-to-node=\"7,2,1,1,0\" data-index-in-node=\"0\"\u003eOutdoor Stabilized Pools (CYA 15–30 ppm):\u003c\/b\u003e\u003cspan\u003e Up to \u003c\/span\u003e\u003cb data-path-to-node=\"7,2,1,1,0\" data-index-in-node=\"48\"\u003e1,200,000 to 1,500,000 US Gallons\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 4,\u003c\/span\u003e\u003cspan\u003e540,\u003c\/span\u003e\u003cspan\u003e000 to 5,\u003c\/span\u003e\u003cspan\u003e680,\u003c\/span\u003e\u003cspan\u003e000 L).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,1,2,0\"\u003e\u003cb data-path-to-node=\"7,2,1,2,0\" data-index-in-node=\"0\"\u003eOutdoor Waterparks, Wave Pools \u0026amp; Surf Lagoons:\u003c\/b\u003e\u003cspan\u003e Pools up to \u003c\/span\u003e\u003cb data-path-to-node=\"7,2,1,2,0\" data-index-in-node=\"59\"\u003e600,000 to 800,000 US Gallons\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 2,\u003c\/span\u003e\u003cspan\u003e270,\u003c\/span\u003e\u003cspan\u003e000 to 3,\u003c\/span\u003e\u003cspan\u003e028,\u003c\/span\u003e\u003cspan\u003e000 L) under peak summer bather loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eBooster Pump Specification:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"28\"\u003e1.5 HP Hayward Centrifugal Pump\u003c\/b\u003e\u003cspan\u003e (commercial closed-impeller wet end,\u003c\/span\u003e\u003cspan\u003e NEMA 56J face motor).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eHydraulic Connections:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"7,4,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,1,0,0\"\u003e\u003cb data-path-to-node=\"7,4,1,0,0\" data-index-in-node=\"0\"\u003eInlet (Water Supply):\u003c\/b\u003e\u003cspan\u003e 1\" Schedule 80 PVC Slip \/ Socket (regulated incoming supply:\u003c\/span\u003e\u003cspan\u003e 15–20 PSI).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,1,1,0\"\u003e\u003cb data-path-to-node=\"7,4,1,1,0\" data-index-in-node=\"0\"\u003eOutlet (Discharge\/Injection):\u003c\/b\u003e\u003cspan\u003e 1-1\/2\" Schedule 80 PVC Slip \/ Socket with included union check valve,\u003c\/span\u003e\u003cspan\u003e manual flow throttling valve,\u003c\/span\u003e\u003cspan\u003e and inline flow meter.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eElectrical Specifications \u0026amp; Approvals:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"7,5,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,1,0,0\"\u003e\u003cb data-path-to-node=\"7,5,1,0,0\" data-index-in-node=\"0\"\u003ePrimary Power Supply:\u003c\/b\u003e\u003cspan\u003e 120V \/ 240V AC (field-switchable),\u003c\/span\u003e\u003cspan\u003e 60 Hz,\u003c\/span\u003e\u003cspan\u003e 1-Phase,\u003c\/span\u003e\u003cspan\u003e 20 Amp dedicated branch circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,1,1,0\"\u003e\u003cb data-path-to-node=\"7,5,1,1,0\" data-index-in-node=\"0\"\u003eExternal Controller Trigger:\u003c\/b\u003e\u003cspan\u003e 120V AC switched feed signal from Pool Link 500\/1000 Series ORP \/ Free Chlorine relays.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,1,2,0\"\u003e\u003cb data-path-to-node=\"7,5,1,2,0\" data-index-in-node=\"0\"\u003eCertifications:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"7,5,1,2,0\" data-index-in-node=\"16\"\u003eCSA Certified\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e NSF\/ANSI Standard 50 commercial listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,6,0\"\u003e\u003cb data-path-to-node=\"7,6,0\" data-index-in-node=\"0\"\u003eOverall Footprint Dimensions:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"7,6,0\" data-index-in-node=\"44\"\u003e42.0\" W × 36.0\" D × 66.0\" H\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 106.\u003c\/span\u003e\u003cspan\u003e7 cm W × 91.\u003c\/span\u003e\u003cspan\u003e4 cm D × 167.\u003c\/span\u003e\u003cspan\u003e6 cm H).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eConsumable Tablet Specification\u003c\/h3\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eSpecified Chemistry:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"21\"\u003eAccu-Tab Blue SI 3-1\/8\" Calcium Hypochlorite Tablets\u003c\/b\u003e\u003cspan\u003e (68% nominal \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"Ca(OCl)_2\" data-index-in-node=\"87\"\u003e$Ca(OCl)_2$\u003c\/span\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e 65% minimum available chlorine).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eScale Inhibitor Chemistry (SI):\u003c\/b\u003e\u003cspan\u003e Formulated with a proprietary polyphosphate scale inhibitor that sequesters calcium directly at the dissolution boundary layer,\u003c\/span\u003e\u003cspan\u003e preventing calcium carbonate (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"CaCO_3\" data-index-in-node=\"190\"\u003e$CaCO_3$\u003c\/span\u003e\u003cspan\u003e) scale formation on the sieve grid,\u003c\/span\u003e\u003cspan\u003e discharge check valves,\u003c\/span\u003e\u003cspan\u003e and pump impeller.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eCritical Chemical Safety Mandate:\u003c\/b\u003e\u003cspan\u003e Never mix chemicals.\u003c\/span\u003e\u003cspan\u003e Loading trichlor,\u003c\/span\u003e\u003cspan\u003e dichlor,\u003c\/span\u003e\u003cspan\u003e calcium chloride,\u003c\/span\u003e\u003cspan\u003e or organic stabilized pucks into the 3500 hopper will trigger rapid exothermic decomposition,\u003c\/span\u003e\u003cspan\u003e toxic gas generation,\u003c\/span\u003e\u003cspan\u003e and severe explosion risk.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"12\"\u003eField Plumbing \u0026amp; Installation Architecture\u003c\/h3\u003e\n\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cdiv class=\"code-block ng-tns-c493897606-113 ng-animate-disabled ng-trigger ng-trigger-codeBlockRevealAnimation\" data-hveid=\"0\" data-ved=\"0CAAQhtANahgKEwir7Pqow9qXAxUAAAAAHQAAAAAQiQg\"\u003e\n\u003c!----\u003e\n\u003cdiv class=\"formatted-code-block-internal-container ng-tns-c493897606-113\"\u003e\n\u003cdiv class=\"animated-opacity ng-tns-c493897606-113\"\u003e\n\u003c!----\u003e\n\u003cpre class=\"ng-tns-c493897606-113\"\u003e\u003ccode role=\"text\" data-test-id=\"code-content\" class=\"code-container formatted ng-tns-c493897606-113 no-decoration-radius\"\u003e                 Pool Recirculation Loop (Post-Filter)\n                             │\n            ┌────────────────┴────────────────┐\n            │                                 │\n            ▼                                 ▼\n      [Shut-off Valve]                  [Shut-off Valve]\n            │                                 ▲\n            ▼                                 │\n  [Inlet Pressure Regulator]          [Discharge Check Valve]\n     (Set to 15-20 PSI)                       ▲\n            │                                 │\n            ▼                          [Throttling Valve]\n  ┌───────────────────────────────────────────┴───────────────────┐\n  │  Accu-Tab PowerBase 3500 Base Unit                            │\n  │                                                               │\n  │  [500 lb Tablet Hopper] ──\u0026gt; [Erosion Sieve Plate]             │\n  │                                   │                           │\n  │                                   ▼                           │\n  │  [Inlet Float Valve]    ──\u0026gt; [Solution Holding Basin]          │\n  │                                   │                           │\n  │                                   ▼                           │\n  │  [Low\/High Level Floats] ──\u0026gt; [1.5 HP Hayward Booster Pump]   │\n  └───────────────────────────────────────────────────────────────┘\n\u003c\/code\u003e\u003c\/pre\u003e\n\u003c!----\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003col start=\"1\" data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eClean Water Supply Line:\u003c\/b\u003e\u003cspan\u003e Supply water must be tapped downstream of the pool filtration filters (to prevent debris clogging the internal sieve plate or float valve) and upstream of any pool heaters or acid injection points.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eDischarge Backpressure Management:\u003c\/b\u003e\u003cspan\u003e The 1.\u003c\/span\u003e\u003cspan\u003e5 HP booster produces significant dynamic head; plumb the discharge line into the center stream of the return main with an industrial chemical injection quill to ensure immediate dilution.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003ePool Link Control Setup:\u003c\/b\u003e\u003cspan\u003e Interlock the 3500 120V trigger to the primary Chlorine\/ORP relay on the Pool Link 500\/1000 controller.\u003c\/span\u003e\u003cspan\u003e Set a controller feed-limit safety timer (typically 15 to 20 minutes) to prevent accidental continuous chemical feed in the event of an external sample stream or probe fault.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":68030060757103,"sku":"9501121-HP-CSA","price":21197.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/Accu-Tab1030.webp?v=1793117712","url":"https:\/\/commercialpoolandspasupplies.com\/products\/accutab-powerbase-3500-tablet-chlorination-system-w-1-5hp-hayward-pump-csa","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}