{"product_id":"acid-rite-450-ph-adjustment-system-w-1hp-hayward-pump-csa","title":"Acid-Rite 450 pH Adjustment System w\/ 1hp Hayward Pump,CSA","description":"\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003eAcid-Rite 450 pH Adjustment System w\/ 1.0 HP Hayward Booster Pump (CSA Certified)\u003c\/b\u003e\u003cspan\u003e is an engineered,\u003c\/span\u003e\u003cspan\u003e solid-acid erosion feeder developed by Westlake Water Solutions (Axiall\/PPG) for automated pH depression in commercial aquatic facilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\"\u003e\u003cspan\u003eDesigned as a direct alternative to liquid muriatic acid (hydrochloric acid) storage tanks and metering pumps,\u003c\/span\u003e\u003cspan\u003e the Acid-Rite 450 utilizes dry,\u003c\/span\u003e\u003cspan\u003e solid sodium bisulfate (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"NaHSO_4\" data-index-in-node=\"167\"\u003e$NaHSO_4$\u003c\/span\u003e\u003cspan\u003e) tablets.\u003c\/span\u003e\u003cspan\u003e It eliminates airborne acid fuming,\u003c\/span\u003e\u003cspan\u003e chemical pump vapor lock,\u003c\/span\u003e\u003cspan\u003e off-gassing degradation of mechanical room equipment,\u003c\/span\u003e\u003cspan\u003e and liquid acid splash hazards while interfacing directly with \u003c\/span\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"364\"\u003ePool Link 500\/1000 Series\u003c\/b\u003e\u003cspan\u003e pH controllers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"attachment-container search-images md-has-block-component\"\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eOperating Principle \u0026amp; Controlled Erosion Dynamics\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eControlled Bottom-Layer Dissolution:\u003c\/b\u003e\u003cspan\u003e The dry acid tablets sit inside an upper containment hopper suspended over a calibrated erosion grid plate.\u003c\/span\u003e\u003cspan\u003e Pressurized side-stream water contacts only the bottom layer of tablets.\u003c\/span\u003e\u003cspan\u003e The bulk dry tablets above stay completely dry,\u003c\/span\u003e\u003cspan\u003e preventing tablet slumping,\u003c\/span\u003e\u003cspan\u003e bridging,\u003c\/span\u003e\u003cspan\u003e or erratic concentration spikes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eIntegrated Solution Tank \u0026amp; Float Regulator:\u003c\/b\u003e\u003cspan\u003e Acidic solution (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"NaHSO_4\" data-index-in-node=\"61\"\u003e$NaHSO_4$\u003c\/span\u003e\u003cspan\u003e in water) drains into a lower heavy-duty polyethylene holding reservoir.\u003c\/span\u003e\u003cspan\u003e A mechanical float assembly continuously regulates fresh make-up water volume to maintain the correct solution bath level.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003e1.0 HP Centrifugal Booster Injection:\u003c\/b\u003e\u003cspan\u003e A close-coupled \u003c\/span\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"54\"\u003e1.0 HP Hayward commercial centrifugal booster pump\u003c\/b\u003e\u003cspan\u003e draws the dissolved acidic solution from the lower reservoir and injects it downstream into the primary pool filtration return line against prevailing backpressures up to \u003c\/span\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"276\"\u003e30 to 40 PSI\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eSafety Float Interlocks:\u003c\/b\u003e\u003cspan\u003e Integrated high-level and low-level magnetic reed float switches protect against equipment room flooding (high-level water cutoff) and prevent dry-run pump mechanical seal burnout (low-level motor interlock).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eTablet Hopper Capacity:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"24\"\u003e45 lbs (20.4 kg)\u003c\/b\u003e\u003cspan\u003e dry sodium bisulfate tablets.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eAcid Delivery Capacity:\u003c\/b\u003e\u003cspan\u003e Delivers the acid-neutralizing equivalent of up to \u003c\/span\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"75\"\u003e4.5 to 5.0 gallons of 31.45% muriatic acid per hour\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 9.\u003c\/span\u003e\u003cspan\u003e5 to 10.\u003c\/span\u003e\u003cspan\u003e5 lbs\/hr of equivalent dry acid delivery).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eFacility Sizing Guidelines:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"8,2,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,1,0,0\"\u003e\u003cb data-path-to-node=\"8,2,1,0,0\" data-index-in-node=\"0\"\u003eCommercial Competition Pools \/ Natatoriums:\u003c\/b\u003e\u003cspan\u003e Up to \u003c\/span\u003e\u003cb data-path-to-node=\"8,2,1,0,0\" data-index-in-node=\"50\"\u003e400,000 to 500,000 US Gallons\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 1,\u003c\/span\u003e\u003cspan\u003e514,\u003c\/span\u003e\u003cspan\u003e000 to 1,\u003c\/span\u003e\u003cspan\u003e892,\u003c\/span\u003e\u003cspan\u003e000 L).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,1,1,0\"\u003e\u003cb data-path-to-node=\"8,2,1,1,0\" data-index-in-node=\"0\"\u003eOutdoor Waterparks \u0026amp; High-Load Bather Pools:\u003c\/b\u003e\u003cspan\u003e Sized for pools up to \u003c\/span\u003e\u003cb data-path-to-node=\"8,2,1,1,0\" data-index-in-node=\"67\"\u003e150,000 to 250,000 US Gallons\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 568,\u003c\/span\u003e\u003cspan\u003e000 to 946,\u003c\/span\u003e\u003cspan\u003e000 L) depending on turnover rate and chlorine source alkalinity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eBooster Pump Specification:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"28\"\u003e1.0 HP Hayward Centrifugal Pump\u003c\/b\u003e\u003cspan\u003e (commercial closed-impeller wet end,\u003c\/span\u003e\u003cspan\u003e continuous-duty motor).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eHydraulic Connections:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"8,4,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,1,0,0\"\u003e\u003cb data-path-to-node=\"8,4,1,0,0\" data-index-in-node=\"0\"\u003eInlet (Water Supply):\u003c\/b\u003e\u003cspan\u003e 1\" Schedule 80 PVC Slip \/ Socket (regulated incoming supply:\u003c\/span\u003e\u003cspan\u003e 15 to 20 PSI).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,1,1,0\"\u003e\u003cb data-path-to-node=\"8,4,1,1,0\" data-index-in-node=\"0\"\u003eOutlet (Discharge\/Injection):\u003c\/b\u003e\u003cspan\u003e 1\" Schedule 80 PVC Slip \/ Socket with included union check valve and manual throttling valve.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eElectrical Specifications \u0026amp; Approvals:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"8,5,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,1,0,0\"\u003e\u003cb data-path-to-node=\"8,5,1,0,0\" data-index-in-node=\"0\"\u003ePrimary Power Supply:\u003c\/b\u003e\u003cspan\u003e 120V AC,\u003c\/span\u003e\u003cspan\u003e 60 Hz,\u003c\/span\u003e\u003cspan\u003e 1-Phase,\u003c\/span\u003e\u003cspan\u003e 15 to 20 Amp dedicated circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,1,1,0\"\u003e\u003cb data-path-to-node=\"8,5,1,1,0\" data-index-in-node=\"0\"\u003eExternal Controller Interface:\u003c\/b\u003e\u003cspan\u003e 120V AC switched trigger from Pool Link 500\/1000 Series pH feed relays.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,1,2,0\"\u003e\u003cb data-path-to-node=\"8,5,1,2,0\" data-index-in-node=\"0\"\u003eCertifications:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"8,5,1,2,0\" data-index-in-node=\"16\"\u003eCSA Certified\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e NSF\/ANSI Standard 50 commercial listed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eOverall Dimensions:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"34\"\u003e27.5\" W × 20.0\" D × 38.0\" H\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 70 cm W × 51 cm D × 96.\u003c\/span\u003e\u003cspan\u003e5 cm H).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eConsumable Tablet Specification\u003c\/h3\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eSpecified Chemical:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"20\"\u003eAcid-Rite Sodium Bisulfate Tablets\u003c\/b\u003e\u003cspan\u003e (engineered solid \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"NaHSO_4\" data-index-in-node=\"73\"\u003e$NaHSO_4$\u003c\/span\u003e\u003cspan\u003e tablet formulation).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eChemical Handling Safety:\u003c\/b\u003e\u003cspan\u003e Eliminates hydrochloric acid gas (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"HCl\" data-index-in-node=\"60\"\u003e$HCl$\u003c\/span\u003e\u003cspan\u003e) that corrodes nearby electrical switchgear,\u003c\/span\u003e\u003cspan\u003e pump motors,\u003c\/span\u003e\u003cspan\u003e and metal structures in mechanical rooms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eCritical Chemical Safety Mandate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"34\"\u003eNever cross-contaminate or mix with chlorine.\u003c\/b\u003e\u003cspan\u003e Acid-Rite hoppers must exclusively receive sodium bisulfate tablets.\u003c\/span\u003e\u003cspan\u003e Accidental loading of calcium hypochlorite (Accu-Tab) or trichlor tablets will trigger violent exothermic decomposition,\u003c\/span\u003e\u003cspan\u003e lethal chlorine gas release,\u003c\/span\u003e\u003cspan\u003e and explosion hazards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003eWeight and Logistics Profile\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eNet Unit Dry Weight:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"35\"\u003e95 to 110 lbs\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 43.\u003c\/span\u003e\u003cspan\u003e1 to 49.\u003c\/span\u003e\u003cspan\u003e9 kg),\u003c\/span\u003e\u003cspan\u003e including hopper,\u003c\/span\u003e\u003cspan\u003e tank,\u003c\/span\u003e\u003cspan\u003e piping assembly,\u003c\/span\u003e\u003cspan\u003e and the 1.\u003c\/span\u003e\u003cspan\u003e0 HP Hayward pump.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003ePalletized Shipping Weight:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"42\"\u003e155 to 175 lbs\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 70.\u003c\/span\u003e\u003cspan\u003e3 to 79.\u003c\/span\u003e\u003cspan\u003e4 kg),\u003c\/span\u003e\u003cspan\u003e including custom pallet,\u003c\/span\u003e\u003cspan\u003e protective corrugated crating,\u003c\/span\u003e\u003cspan\u003e and boxed installation valves.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eShipping Dimensions (Palletized):\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"48\"\u003e36\" L × 32\" W × 45\" H\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eFreight Classification:\u003c\/b\u003e\u003cspan\u003e Ships via \u003c\/span\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"34\"\u003eLTL Motor Freight\u003c\/b\u003e\u003cspan\u003e (Class 150 to 200).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":68030070325359,"sku":"9501122-HP-CSA","price":7101.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/Accu-Tab1030.webp?v=1793117712","url":"https:\/\/commercialpoolandspasupplies.com\/products\/acid-rite-450-ph-adjustment-system-w-1hp-hayward-pump-csa","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}