{"product_id":"cat-4000-standard-package-w-wifi-transceiver","title":"CAT 2000 CONTROLLER \u0026 SENSORS","description":"\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\" class=\"\"\u003eCAT 2000 Controller \u0026amp; Sensors\u003c\/b\u003e\u003cspan class=\"\"\u003e package (Hayward Commercial Aquatics \/ CAT Controllers) is a core commercial automation package configured without the pre-assembled acrylic backboard or standalone flow cell manifold.\u003c\/span\u003e\u003cspan\u003e Engineered for replacement retrofits,\u003c\/span\u003e\u003cspan\u003e custom equipment panel integration,\u003c\/span\u003e\u003cspan\u003e or direct inline probe installations in commercial swimming pools,\u003c\/span\u003e\u003cspan\u003e splash pads,\u003c\/span\u003e\u003cspan\u003e therapy spas,\u003c\/span\u003e\u003cspan\u003e and municipal aquatic facilities,\u003c\/span\u003e\u003cspan\u003e it provides microprocessor-driven dual-channel monitoring and proportional chemical dosing control for pH and sanitization (ORP\/Chlorine\/Bromine).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"1\"\u003eSystem Overview \u0026amp; Package Components\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cspan\u003eThis configuration delivers the core electronics,\u003c\/span\u003e\u003cspan\u003e analytical probes,\u003c\/span\u003e\u003cspan\u003e and field wiring hardware required to automate water chemistry control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eCAT 2000 Microprocessor Controller:\u003c\/b\u003e\u003cspan\u003e Solid-state digital controller featuring dual bright-red digital LED displays that continuously report real-time pH and ORP readings,\u003c\/span\u003e\u003cspan\u003e feed activation status,\u003c\/span\u003e\u003cspan\u003e and active alarm states.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eProfessional Glass-Body pH Sensor:\u003c\/b\u003e\u003cspan\u003e Heavy-duty,\u003c\/span\u003e\u003cspan\u003e combination sealed glass electrode with an internal reference electrolyte chamber,\u003c\/span\u003e\u003cspan\u003e porous Teflon junction,\u003c\/span\u003e\u003cspan\u003e and shielded low-noise coaxial lead terminated with a BNC connector.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eCommercial Platinum ORP Sensor:\u003c\/b\u003e\u003cspan\u003e High-purity platinum-band sensor designed for rapid oxidation-reduction potential response across varying sanitizer residual levels,\u003c\/span\u003e\u003cspan\u003e terminated with a moisture-resistant BNC connector.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eInline \/ Flow Cell Mounting Fittings:\u003c\/b\u003e\u003cspan class=\"\"\u003e Standard 1\/2-inch or 3\/4-inch NPT compression gland adapters (or flow cell sensor O-ring retainers) for securing the probes into existing flow cells or plumbing tees.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eSurface Wall-Mount Hardware:\u003c\/b\u003e\u003cspan\u003e External mounting ears and hardware for direct wall or panel attachment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eMonitoring \u0026amp; Control Ranges:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"6,0,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,1,0,0\"\u003e\u003cb data-path-to-node=\"6,0,1,0,0\" data-index-in-node=\"0\"\u003epH Range:\u003c\/b\u003e\u003cspan\u003e 7.\u003c\/span\u003e\u003cspan\u003e0 to 8.\u003c\/span\u003e\u003cspan\u003e4 (resolution:\u003c\/span\u003e\u003cspan\u003e 0.\u003c\/span\u003e\u003cspan\u003e1 pH)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,1,1,0\"\u003e\u003cb data-path-to-node=\"6,0,1,1,0\" data-index-in-node=\"0\"\u003eORP Range:\u003c\/b\u003e\u003cspan\u003e 200 to 999 mV (resolution:\u003c\/span\u003e\u003cspan\u003e 1 mV)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eControl Modes:\u003c\/b\u003e\u003cspan\u003e Continuous feed,\u003c\/span\u003e\u003cspan\u003e Proportional feed (pulse-frequency modulation to prevent chemical overshooting),\u003c\/span\u003e\u003cspan\u003e and Manual feed override.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eOutputs \u0026amp; Relays:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"6,2,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,1,0,0\"\u003e\u003cspan\u003eTwo powered or dry-contact chemical feed relays (dedicated pH and ORP\/sanitizer circuits),\u003c\/span\u003e\u003cspan\u003e typically rated for 115V AC \/ 230V AC up to 5A resistive load per channel.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,1,1,0\"\u003e\u003cspan\u003eCompatible with peristaltic dosing pumps,\u003c\/span\u003e\u003cspan\u003e electronic diaphragm metering pumps,\u003c\/span\u003e\u003cspan\u003e erosion feeder solenoid valves,\u003c\/span\u003e\u003cspan\u003e CO₂ gas injection systems,\u003c\/span\u003e\u003cspan\u003e and saltwater chlorination cells.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eSafety \u0026amp; Alarm Features:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"6,3,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,1,0,0\"\u003e\u003cspan\u003eIndependent programmable chemical feed timeout clocks (cuts dosing if setpoints are not satisfied within an allotted operational window).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,1,1,0\"\u003e\u003cspan\u003eHigh and low parameter visual LED indicators and audible alerts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,1,2,0\"\u003e\u003cspan\u003eFlow switch input terminal (dry contact) for interlock integration with an external pressure switch,\u003c\/span\u003e\u003cspan\u003e flow switch,\u003c\/span\u003e\u003cspan\u003e or circulation pump starter.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eEnclosure:\u003c\/b\u003e\u003cspan\u003e NEMA 4X \/ IP66 weather-resistant,\u003c\/span\u003e\u003cspan\u003e UV-stabilized thermoplastic housing with a clear,\u003c\/span\u003e\u003cspan\u003e lockable hinged faceplate cover to protect against chlorinated moisture,\u003c\/span\u003e\u003cspan\u003e dust,\u003c\/span\u003e\u003cspan\u003e and washdown spray.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eElectrical Requirements:\u003c\/b\u003e\u003cspan\u003e Universal 115V \/ 230V AC,\u003c\/span\u003e\u003cspan\u003e 50\/60 Hz,\u003c\/span\u003e\u003cspan\u003e 0.\u003c\/span\u003e\u003cspan\u003e5A input (field configurable via internal terminal block jumpers).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"8\"\u003ePhysical Dimensions \u0026amp; Environmental Ratings\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eEnclosure Footprint:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"35\"\u003e8.5\" H × 7.0\" W × 4.5\" D\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 21.\u003c\/span\u003e\u003cspan\u003e6 cm × 17.\u003c\/span\u003e\u003cspan\u003e8 cm × 11.\u003c\/span\u003e\u003cspan\u003e4 cm).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eSensor Lead Length:\u003c\/b\u003e\u003cspan\u003e Standard \u003c\/span\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"29\"\u003e10-foot\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 3.\u003c\/span\u003e\u003cspan\u003e0 m) low-noise shielded coaxial cable per sensor.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eOperating Ambient Temperature:\u003c\/b\u003e\u003cspan\u003e 32°F to 120°F (0°C to 49°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eMaximum Sensor Operating Pressure:\u003c\/b\u003e\u003cspan\u003e 50 PSI (approx.\u003c\/span\u003e\u003cspan\u003e 3.\u003c\/span\u003e\u003cspan\u003e45 bar) in standard commercial flow cell housings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":67968512000111,"sku":"CAT2000CSO","price":4758.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/Cat2000_6e94.jpg?v=1792678647","url":"https:\/\/commercialpoolandspasupplies.com\/products\/cat-4000-standard-package-w-wifi-transceiver","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}