{"product_id":"coates-electric-pool-heater-15kw-240v-single-phase-salt-water-application","title":"Coates Electric Pool Heater, 15kw 240V Single Phase, Salt Water Application","description":"\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003eCoates 15kW 240V Single-Phase Electric Pool \u0026amp; Spa Heater for Salt Water Applications\u003c\/b\u003e\u003cspan\u003e (Model \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"96\"\u003e12415CES\u003c\/b\u003e\u003cspan\u003e \/ \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"107\"\u003e12415CPHS\u003c\/b\u003e\u003cspan\u003e — designated with the \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"139\"\u003e\"S\"\u003c\/b\u003e\u003cspan\u003e saltwater\/corrosion-resistant package) is engineered for commercial hydrotherapy tanks,\u003c\/span\u003e\u003cspan\u003e high-occupancy resort spas,\u003c\/span\u003e\u003cspan\u003e and municipal plunge pools utilizing electrolytic salt chlorine generators (typically operating between 2,\u003c\/span\u003e\u003cspan\u003e500 and 4,\u003c\/span\u003e\u003cspan\u003e500+ ppm TDS\/NaCl).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\"\u003e\u003cspan\u003eBecause saline environments accelerate galvanic action and chloride pitting on conventional immersion heating elements,\u003c\/span\u003e\u003cspan\u003e this unit integrates upgraded metallurgy and specialized barrier coatings to prevent premature element burnout and vessel degradation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eElectrical \u0026amp; Heating Performance\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eModel Designation:\u003c\/b\u003e\u003cspan\u003e Coates 12415CES \/ 12415CPHS series (\u003c\/span\u003e\u003ccode data-path-to-node=\"4,0,0\" data-index-in-node=\"55\"\u003e124\u003c\/code\u003e\u003cspan\u003e designates 1-Phase 240V; suffix designates Saltwater\/Titanium package).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eHeating Capacity:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"18\"\u003e15 kW (15,000 Watts)\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eThermal Output:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"16\"\u003e51,182 BTU\/hr\u003c\/b\u003e\u003cspan\u003e (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"15\\text{ kW} \\times 3,412.142\\text{ BTU\/kWh}\" data-index-in-node=\"31\"\u003e$15\\text{ kW} \\times 3,412.142\\text{ BTU\/kWh}$\u003c\/span\u003e\u003cspan\u003e).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eOperating Voltage:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"19\"\u003e240V AC\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"28\"\u003eSingle-Phase (1Ø)\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e 2-wire plus ground,\u003c\/span\u003e\u003cspan\u003e 60 Hz.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\"\u003eFull Load Amperage (FLA):\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"26\"\u003e62.5 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv data-path-to-node=\"4,4,1\"\u003e\n\u003cdiv class=\"math-block\" data-math=\"\\text{FLA} = \\frac{15,000\\text{ W}}{240\\text{ V}} = 62.5\\text{ A}\"\u003e$$\\text{FLA} = \\frac{15,000\\text{ W}}{240\\text{ V}} = 62.5\\text{ A}$$\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,0\"\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"0\"\u003eOvercurrent Protection (Breaker Sizing):\u003c\/b\u003e\u003cspan\u003e Requires a dedicated \u003c\/span\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"62\"\u003e2-pole 80-Amp circuit breaker\u003c\/b\u003e\u003cspan\u003e conforming to NEC 125% continuous-duty branch requirements (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"62.5\\text{ A} \\times 1.25 = 78.13\\text{ A}\" data-index-in-node=\"152\"\u003e$62.5\\text{ A} \\times 1.25 = 78.13\\text{ A}$\u003c\/span\u003e\u003cspan\u003e minimum branch rating,\u003c\/span\u003e\u003cspan\u003e standardizing on an \u003c\/span\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"238\"\u003e80A\u003c\/b\u003e\u003cspan\u003e 2-pole breaker).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,6,0\"\u003e\u003cb data-path-to-node=\"4,6,0\" data-index-in-node=\"0\"\u003eConductor Sizing:\u003c\/b\u003e\u003cspan\u003e Minimum \u003c\/span\u003e\u003cb data-path-to-node=\"4,6,0\" data-index-in-node=\"26\"\u003e#4 AWG or #3 AWG THHN\/THWN copper conductor\u003c\/b\u003e\u003cspan\u003e (rated 75°C\/90°C terminals,\u003c\/span\u003e\u003cspan\u003e adjusted for ambient derating and run length).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eSalt Water Construction \u0026amp; Metallurgy Upgrades\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eTitanium \/ Incoloy 825 Sheathed Elements:\u003c\/b\u003e\u003cspan class=\"\"\u003e Standard immersion elements are replaced with \u003c\/span\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"88\" class=\"\"\u003eTitanium\u003c\/b\u003e\u003cspan class=\"\"\u003e or high-nickel\/high-molybdenum \u003c\/span\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"128\"\u003eIncoloy 825\u003c\/b\u003e\u003cspan class=\"\"\u003e sheathing to withstand chloride-induced stress corrosion cracking (SCC),\u003c\/span\u003e\u003cspan class=\"\"\u003e scale accumulation,\u003c\/span\u003e\u003cspan\u003e and localized pitting from dissolved sodium chloride.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003ePassivated \/ Coated Pressure Vessel:\u003c\/b\u003e\u003cspan class=\"\"\u003e Extended cylindrical pressure chamber fabricated from heavy-gauge 316L stainless steel or carbon steel lined with a high-build baked phenolic epoxy\/fluoropolymer protective barrier to isolate metal surfaces from saline electrolytic attack.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eSacrificial Anode Protection:\u003c\/b\u003e\u003cspan\u003e Includes an accessible sacrificial zinc or magnesium anode plug port to provide cathodic protection against stray currents and galvanic cell formation common in saltwater plumbing loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eCabinet \u0026amp; Enclosure:\u003c\/b\u003e\u003cspan\u003e NEMA 1 industrial painted heavy-gauge steel cabinet finished with a corrosion-inhibiting powder coat to resist airborne salt aerosols in humid mechanical rooms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\" class=\"\"\u003eConstruction \u0026amp; Safety Architecture\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\" class=\"\"\u003eCabinet \u0026amp; Enclosure:\u003c\/b\u003e\u003cspan class=\"\"\u003e NEMA 1 industrial painted steel cabinet with a removable front panel for terminal inspections,\u003c\/span\u003e\u003cspan\u003e heavy-duty 2-pole magnetic contactor servicing,\u003c\/span\u003e\u003cspan class=\"\"\u003e and field wire terminations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\" class=\"\"\u003eIntegrated Safety Controls:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"10,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,1,0,0\"\u003e\u003cspan\u003eDual-dial adjustable thermostatic controller calibrated up to 104°F (40°C) for commercial spa compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,1,1,0\"\u003e\u003cspan\u003eManual-reset High-Limit safety cutout set to de-energize the magnetic contactor control circuit at 122°F (50°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,1,2,0\"\u003e\u003cspan\u003ePressure\/flow-interlock switch preventing heating element contactors from pulling in during low-flow,\u003c\/span\u003e\u003cspan\u003e pump loss,\u003c\/span\u003e\u003cspan\u003e or deadhead conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"12\" class=\"\"\u003eHydraulic \u0026amp; Plumbing Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\" class=\"\"\u003ePlumbing Connections:\u003c\/b\u003e\u003cspan class=\"\"\u003e Standard \u003c\/span\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"31\"\u003e1-1\/2\" NPT\u003c\/b\u003e\u003cspan class=\"\"\u003e female inlet and outlet ports (adapted via Schedule 80 CPVC unions).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\" class=\"\"\u003eEquipment Sequencing in Salt Systems:\u003c\/b\u003e\u003cspan\u003e Must always be installed \u003c\/span\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"63\"\u003eupstream of the electrolytic chlorine generator cell\u003c\/b\u003e\u003cspan\u003e (separated by a check valve where applicable) to prevent hyper-concentrated chlorine gas or acidic pockets from pooling inside the heater vessel during pump shutdowns.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eFlow Rate Parameters:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"13,2,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,1,0,0\"\u003e\u003cb data-path-to-node=\"13,2,1,0,0\" data-index-in-node=\"0\"\u003eMinimum Flow Rate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"13,2,1,0,0\" data-index-in-node=\"19\"\u003e15 to 20 GPM\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 57 to 76 LPM) required to trip the internal safety flow switch.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,1,1,0\"\u003e\u003cb data-path-to-node=\"13,2,1,1,0\" data-index-in-node=\"0\"\u003eMaximum Flow Rate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"13,2,1,1,0\" data-index-in-node=\"19\"\u003e60 to 70 GPM\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 227 to 265 LPM); filtration loops operating at higher GPM mandate an external plumbed bypass manifold.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eMaximum Working Pressure:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"26\"\u003e60 PSI\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 4.\u003c\/span\u003e\u003cspan\u003e14 bar).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\" class=\"\"\u003eDimensions, Net Weight \u0026amp; Shipping Weight\u003c\/h3\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"0\" class=\"\"\u003eUnit Dimensions:\u003c\/b\u003e\u003cspan class=\"\"\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"31\" class=\"\"\u003e19.5\" L × 10.0\" W × 14.5\" H\u003c\/b\u003e\u003cspan class=\"\"\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 49.\u003c\/span\u003e\u003cspan\u003e5 cm × 25.\u003c\/span\u003e\u003cspan\u003e4 cm × 36.\u003c\/span\u003e\u003cspan\u003e8 cm).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"0\" class=\"\"\u003eNet Unit Weight:\u003c\/b\u003e\u003cspan class=\"\"\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"31\" class=\"\"\u003e48 to 54 lbs\u003c\/b\u003e\u003cspan class=\"\"\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 21.\u003c\/span\u003e\u003cspan\u003e8 to 24.\u003c\/span\u003e\u003cspan\u003e5 kg).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"16,2,0\" data-index-in-node=\"0\" class=\"\"\u003ePackaged Shipping Dimensions:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"16,2,0\" data-index-in-node=\"44\"\u003e22\" L × 13\" W × 17\" H\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"16,3,0\" data-index-in-node=\"0\" class=\"\"\u003ePackaged Shipping Weight:\u003c\/b\u003e\u003cspan class=\"\"\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"16,3,0\" data-index-in-node=\"40\" class=\"\"\u003e60 to 68 lbs\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan class=\"\"\u003e 27.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 to 30.\u003c\/span\u003e\u003cspan\u003e8 kg) in heavy-duty reinforced corrugated packaging.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"18\" class=\"\"\u003eEstimated Temperature Rise Rates\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"19\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePool \/ Spa Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWater Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eApprox. Temperature Rise per Hour\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,1,0,0\"\u003e\u003cb data-path-to-node=\"19,1,0,0\" data-index-in-node=\"0\"\u003e500 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,1,1,0\"\u003e~4,170 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,1,2,0\"\u003e\u003cb data-path-to-node=\"19,1,2,0\" data-index-in-node=\"0\"\u003e12.3°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,2,0,0\"\u003e\u003cb data-path-to-node=\"19,2,0,0\" data-index-in-node=\"0\"\u003e1,000 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,2,1,0\"\u003e~8,340 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,2,2,0\"\u003e\u003cb data-path-to-node=\"19,2,2,0\" data-index-in-node=\"0\"\u003e6.1°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,3,0,0\"\u003e\u003cb data-path-to-node=\"19,3,0,0\" data-index-in-node=\"0\"\u003e2,500 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,3,1,0\"\u003e~20,850 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,3,2,0\"\u003e\u003cb data-path-to-node=\"19,3,2,0\" data-index-in-node=\"0\"\u003e2.5°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,4,0,0\"\u003e\u003cb data-path-to-node=\"19,4,0,0\" data-index-in-node=\"0\"\u003e5,000 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,4,1,0\"\u003e~41,700 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,4,2,0\"\u003e\u003cb data-path-to-node=\"19,4,2,0\" data-index-in-node=\"0\"\u003e1.2°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-path-to-node=\"20\"\u003e\u003ci data-path-to-node=\"20\" data-index-in-node=\"0\" class=\"\"\u003e(Calculation: \u003cspan class=\"math-inline\" data-math=\"\\text{Rise (°F\/hr)} = \\frac{51,182\\text{ BTU\/hr}}{\\text{Gallons} \\times 8.34\\text{ lbs\/gal}}\" data-index-in-node=\"14\"\u003e$\\text{Rise (°F\/hr)} = \\frac{51,182\\text{ BTU\/hr}}{\\text{Gallons} \\times 8.34\\text{ lbs\/gal}}$\u003c\/span\u003e, baseline heat-up rate assuming covered vessel without ambient radiation losses.)\u003c\/i\u003e\u003c\/p\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper md-has-block-component\"\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":68044324864111,"sku":"12415PHS-CN","price":13363.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/ILSbig.jpg?v=1793199527","url":"https:\/\/commercialpoolandspasupplies.com\/products\/coates-electric-pool-heater-15kw-240v-single-phase-salt-water-application","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}