{"product_id":"coates-electric-pool-heater-24kw-240v-single-phase-salt-water-application","title":"Coates Electric Pool Heater, 24kw 240V Single Phase, Salt Water Application","description":"\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003eCoates 24kW 240V Single-Phase Electric Pool \u0026amp; Spa Heater for Salt Water Applications\u003c\/b\u003e\u003cspan\u003e (Model \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"96\"\u003e12424CES\u003c\/b\u003e\u003cspan\u003e \/ \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"107\"\u003e12424CPHS\u003c\/b\u003e\u003cspan\u003e — with the \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"128\"\u003e\"S\"\u003c\/b\u003e\u003cspan\u003e saltwater\/corrosion-resistant package) is a heavy-duty,\u003c\/span\u003e\u003cspan\u003e high-capacity inline immersion heater engineered for high-demand commercial swim spas,\u003c\/span\u003e\u003cspan\u003e large hydrotherapy tanks,\u003c\/span\u003e\u003cspan\u003e resort plunge pools,\u003c\/span\u003e\u003cspan\u003e and wellness facilities operating with electrolytic salt chlorine generation systems (typically 2,\u003c\/span\u003e\u003cspan\u003e500 to 4,\u003c\/span\u003e\u003cspan\u003e500+ ppm TDS\/NaCl).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\"\u003e\u003cspan\u003eAt 24kW on a single-phase 240V service,\u003c\/span\u003e\u003cspan\u003e the continuous load reaches 100 Amps.\u003c\/span\u003e\u003cspan\u003e In commercial installations,\u003c\/span\u003e\u003cspan\u003e this demand is commonly configured either as a single heavy feeder or split internally across two parallel branch circuits to adhere to NEC continuous-duty limits and standard subpanel breaker allocations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eElectrical \u0026amp; Heating Performance\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eModel Designation:\u003c\/b\u003e\u003cspan\u003e Coates 12424CES \/ 12424CPHS series (\u003c\/span\u003e\u003ccode data-path-to-node=\"4,0,0\" data-index-in-node=\"55\"\u003e124\u003c\/code\u003e\u003cspan\u003e designates 1-Phase 240V; suffix designates Saltwater\/Titanium package).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eHeating Capacity:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"18\"\u003e24 kW (24,000 Watts)\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eThermal Output:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"16\"\u003e81,891 BTU\/hr\u003c\/b\u003e\u003cspan\u003e (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"24\\text{ kW} \\times 3,412.142\\text{ BTU\/kWh}\" data-index-in-node=\"31\"\u003e$24\\text{ kW} \\times 3,412.142\\text{ BTU\/kWh}$\u003c\/span\u003e\u003cspan\u003e).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eOperating Voltage:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"19\"\u003e240V AC\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"28\"\u003eSingle-Phase (1Ø)\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e 2-wire plus ground,\u003c\/span\u003e\u003cspan\u003e 60 Hz.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\"\u003eTotal Full Load Amperage (FLA):\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"32\"\u003e100.0 Amps\u003c\/b\u003e\u003c\/p\u003e\n\u003cdiv data-path-to-node=\"4,4,1\"\u003e\n\u003cdiv class=\"math-block\" data-math=\"\\text{FLA} = \\frac{24,000\\text{ W}}{240\\text{ V}} = 100.0\\text{ A}\"\u003e$$\\text{FLA} = \\frac{24,000\\text{ W}}{240\\text{ V}} = 100.0\\text{ A}$$\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,0\"\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"0\"\u003eCircuit \u0026amp; Overcurrent Protection Configurations:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"4,5,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,1,0,0\"\u003e\u003cb data-path-to-node=\"4,5,1,0,0\" data-index-in-node=\"0\"\u003eSingle Dedicated Circuit:\u003c\/b\u003e\u003cspan\u003e Requires a \u003c\/span\u003e\u003cb data-path-to-node=\"4,5,1,0,0\" data-index-in-node=\"37\"\u003e2-pole 125-Amp circuit breaker\u003c\/b\u003e\u003cspan\u003e rated for continuous duty (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"100.0\\text{ A} \\times 1.25 = 125.0\\text{ A}\" data-index-in-node=\"95\"\u003e$100.0\\text{ A} \\times 1.25 = 125.0\\text{ A}$\u003c\/span\u003e\u003cspan\u003e).\u003c\/span\u003e\u003cspan\u003e Minimum conductor size:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,5,1,0,0\" data-index-in-node=\"165\"\u003e#1 AWG or #1\/0 AWG THHN\/THWN copper\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,1,1,0\"\u003e\u003cb data-path-to-node=\"4,5,1,1,0\" data-index-in-node=\"0\"\u003eSplit Dual-Circuit Configuration (Standard Field Option):\u003c\/b\u003e\u003cspan\u003e Two separate 12kW heating element stages:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"4,5,1,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,1,1,1,0,0\"\u003e\u003cb data-path-to-node=\"4,5,1,1,1,0,0\" data-index-in-node=\"0\"\u003eCircuit 1:\u003c\/b\u003e\u003cspan\u003e 12 kW \/ 50.\u003c\/span\u003e\u003cspan\u003e0 Amps FLA \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"\\rightarrow\" data-index-in-node=\"33\"\u003e$\\rightarrow$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,5,1,1,1,0,0\" data-index-in-node=\"45\"\u003e2-pole 70-Amp breaker\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e minimum \u003c\/span\u003e\u003cb data-path-to-node=\"4,5,1,1,1,0,0\" data-index-in-node=\"76\"\u003e#4 AWG copper\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,1,1,1,1,0\"\u003e\u003cb data-path-to-node=\"4,5,1,1,1,1,0\" data-index-in-node=\"0\"\u003eCircuit 2:\u003c\/b\u003e\u003cspan\u003e 12 kW \/ 50.\u003c\/span\u003e\u003cspan\u003e0 Amps FLA \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"\\rightarrow\" data-index-in-node=\"33\"\u003e$\\rightarrow$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,5,1,1,1,1,0\" data-index-in-node=\"45\"\u003e2-pole 70-Amp breaker\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e minimum \u003c\/span\u003e\u003cb data-path-to-node=\"4,5,1,1,1,1,0\" data-index-in-node=\"76\"\u003e#4 AWG copper\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eSalt Water Construction \u0026amp; Metallurgy Upgrades\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eTitanium \/ Incoloy 825 Sheathed Elements:\u003c\/b\u003e\u003cspan\u003e Standard immersion elements are replaced with \u003c\/span\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"88\"\u003eTitanium\u003c\/b\u003e\u003cspan\u003e or high-molybdenum \u003c\/span\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"116\"\u003eIncoloy 825\u003c\/b\u003e\u003cspan\u003e sheathing to resist chloride-induced stress corrosion cracking (SCC),\u003c\/span\u003e\u003cspan\u003e scale accumulation,\u003c\/span\u003e\u003cspan\u003e and localized pitting from dissolved sodium chloride.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003ePassivated \/ Barrier-Coated Pressure Vessel:\u003c\/b\u003e\u003cspan\u003e Extended cylindrical pressure chamber fabricated from heavy-gauge 316L stainless steel or carbon steel lined with a specialized baked phenolic epoxy\/fluoropolymer protective barrier,\u003c\/span\u003e\u003cspan\u003e isolating the tank substrate from saline electrolytic degradation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eSacrificial Cathodic Protection:\u003c\/b\u003e\u003cspan\u003e Equipped with an accessible sacrificial zinc or magnesium anode plug port to absorb galvanic action and mitigate stray current erosion in the salt plumbing loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eCorrosion-Inhibited Cabinet:\u003c\/b\u003e\u003cspan\u003e Heavy-gauge NEMA 1 industrial painted enclosure finished with an anti-corrosion powder coating to prevent cabinet degradation in high-humidity,\u003c\/span\u003e\u003cspan\u003e salt-vapor mechanical rooms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\" class=\"\"\u003eConstruction \u0026amp; Safety Architecture\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\" class=\"\"\u003eCabinet \u0026amp; Enclosure:\u003c\/b\u003e\u003cspan class=\"\"\u003e NEMA 1 industrial painted steel cabinet with a removable front panel for terminal inspections,\u003c\/span\u003e\u003cspan\u003e dual heavy-duty 2-pole magnetic contactor servicing,\u003c\/span\u003e\u003cspan class=\"\"\u003e and field wire terminations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\" class=\"\"\u003eIntegrated Safety Controls:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"10,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,1,0,0\"\u003e\u003cspan\u003eDual-dial adjustable thermostatic controller calibrated up to 104°F (40°C) for commercial spa compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,1,1,0\"\u003e\u003cspan\u003eManual-reset High-Limit safety cutout set to de-energize the magnetic contactor control circuit at 122°F (50°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,1,2,0\"\u003e\u003cspan\u003ePressure\/flow-interlock switch preventing heating element contactors from pulling in during low-flow,\u003c\/span\u003e\u003cspan\u003e pump loss,\u003c\/span\u003e\u003cspan\u003e or deadhead conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"12\" class=\"\"\u003eHydraulic \u0026amp; Plumbing Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\" class=\"\"\u003ePlumbing Connections:\u003c\/b\u003e\u003cspan class=\"\"\u003e Standard \u003c\/span\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"31\"\u003e1-1\/2\" NPT\u003c\/b\u003e\u003cspan class=\"\"\u003e female inlet and outlet ports (adapted via Schedule 80 CPVC unions into 2\" or 2-1\/2\" headers).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\" class=\"\"\u003eEquipment Sequencing in Salt Systems:\u003c\/b\u003e\u003cspan\u003e Must always be installed \u003c\/span\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"63\"\u003eupstream of the electrolytic chlorine generator cell\u003c\/b\u003e\u003cspan\u003e (with an intervening corrosion-resistant check valve) to prevent hyper-concentrated chlorine gas or acidic pockets from pooling inside the heater vessel during pump shutdowns.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eFlow Rate Parameters:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"13,2,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,1,0,0\"\u003e\u003cb data-path-to-node=\"13,2,1,0,0\" data-index-in-node=\"0\"\u003eMinimum Flow Rate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"13,2,1,0,0\" data-index-in-node=\"19\"\u003e20 GPM\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 76 LPM) required to trip the safety flow switch and prevent localized thermal cavitation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,1,1,0\"\u003e\u003cb data-path-to-node=\"13,2,1,1,0\" data-index-in-node=\"0\"\u003eMaximum Flow Rate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"13,2,1,1,0\" data-index-in-node=\"19\"\u003e60 to 70 GPM\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 227 to 265 LPM); filtration loops operating at higher GPM mandate an external plumbed bypass manifold.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eMaximum Working Pressure:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"26\"\u003e60 PSI\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 4.\u003c\/span\u003e\u003cspan\u003e14 bar).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\" class=\"\"\u003eDimensions, Net Weight \u0026amp; Shipping Weight\u003c\/h3\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"0\" class=\"\"\u003eUnit Dimensions:\u003c\/b\u003e\u003cspan class=\"\"\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"31\" class=\"\"\u003e24.0\" L × 12.0\" W × 16.5\" H\u003c\/b\u003e\u003cspan class=\"\"\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 61.\u003c\/span\u003e\u003cspan\u003e0 cm × 30.\u003c\/span\u003e\u003cspan\u003e5 cm × 41.\u003c\/span\u003e\u003cspan\u003e9 cm).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"0\" class=\"\"\u003eNet Unit Weight:\u003c\/b\u003e\u003cspan class=\"\"\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"31\" class=\"\"\u003e62 to 70 lbs\u003c\/b\u003e\u003cspan class=\"\"\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 28.\u003c\/span\u003e\u003cspan\u003e1 to 31.\u003c\/span\u003e\u003cspan\u003e8 kg).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"16,2,0\" data-index-in-node=\"0\" class=\"\"\u003ePackaged Shipping Dimensions:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"16,2,0\" data-index-in-node=\"44\"\u003e26\" L × 15\" W × 19\" H\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"16,3,0\" data-index-in-node=\"0\" class=\"\"\u003ePackaged Shipping Weight:\u003c\/b\u003e\u003cspan class=\"\"\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"16,3,0\" data-index-in-node=\"40\" class=\"\"\u003e75 to 84 lbs\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan class=\"\"\u003e 34.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 to 38.\u003c\/span\u003e\u003cspan\u003e1 kg) in heavy-duty reinforced corrugated packaging with dense molded foam protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"18\" class=\"\"\u003eEstimated Temperature Rise Rates\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"19\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePool \/ Spa Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWater Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eApprox. Temperature Rise per Hour\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,1,0,0\"\u003e\u003cb data-path-to-node=\"19,1,0,0\" data-index-in-node=\"0\"\u003e500 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,1,1,0\"\u003e~4,170 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,1,2,0\"\u003e\u003cb data-path-to-node=\"19,1,2,0\" data-index-in-node=\"0\"\u003e19.6°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,2,0,0\"\u003e\u003cb data-path-to-node=\"19,2,0,0\" data-index-in-node=\"0\"\u003e1,000 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,2,1,0\"\u003e~8,340 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,2,2,0\"\u003e\u003cb data-path-to-node=\"19,2,2,0\" data-index-in-node=\"0\"\u003e9.8°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,3,0,0\"\u003e\u003cb data-path-to-node=\"19,3,0,0\" data-index-in-node=\"0\"\u003e2,500 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,3,1,0\"\u003e~20,850 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,3,2,0\"\u003e\u003cb data-path-to-node=\"19,3,2,0\" data-index-in-node=\"0\"\u003e3.9°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,4,0,0\"\u003e\u003cb data-path-to-node=\"19,4,0,0\" data-index-in-node=\"0\"\u003e5,000 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,4,1,0\"\u003e~41,700 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,4,2,0\"\u003e\u003cb data-path-to-node=\"19,4,2,0\" data-index-in-node=\"0\"\u003e2.0°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,5,0,0\"\u003e\u003cb data-path-to-node=\"19,5,0,0\" data-index-in-node=\"0\"\u003e10,000 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,5,1,0\"\u003e~83,400 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"19,5,2,0\"\u003e\u003cb data-path-to-node=\"19,5,2,0\" data-index-in-node=\"0\"\u003e1.0°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-path-to-node=\"20\"\u003e\u003ci data-path-to-node=\"20\" data-index-in-node=\"0\" class=\"\"\u003e(Calculation: \u003cspan class=\"math-inline\" data-math=\"\\text{Rise (°F\/hr)} = \\frac{81,891\\text{ BTU\/hr}}{\\text{Gallons} \\times 8.34\\text{ lbs\/gal}}\" data-index-in-node=\"14\"\u003e$\\text{Rise (°F\/hr)} = \\frac{81,891\\text{ BTU\/hr}}{\\text{Gallons} \\times 8.34\\text{ lbs\/gal}}$\u003c\/span\u003e, baseline heat-up rate assuming covered vessel without ambient radiation losses.)\u003c\/i\u003e\u003c\/p\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper md-has-block-component\"\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":68044326240367,"sku":"12424PHS-CN","price":14375.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/ILSbig.jpg?v=1793199527","url":"https:\/\/commercialpoolandspasupplies.com\/products\/coates-electric-pool-heater-24kw-240v-single-phase-salt-water-application","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}