{"product_id":"coates-electric-pool-heater-45kw-240v-single-phase","title":"Coates Electric Pool Heater, 45kw 240V Single Phase","description":"\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003eCoates 45kW 240V Single-Phase Electric Pool \u0026amp; Spa Heater\u003c\/b\u003e\u003cspan\u003e (Model \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"68\"\u003e12445CE\u003c\/b\u003e\u003cspan\u003e \/ \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"78\"\u003e12445CPH\u003c\/b\u003e\u003cspan\u003e) represents an extreme,\u003c\/span\u003e\u003cspan\u003e high-output commercial electric immersion configuration engineered for large commercial hydrotherapy spas,\u003c\/span\u003e\u003cspan\u003e municipal therapy pools,\u003c\/span\u003e\u003cspan\u003e swim-school vessels,\u003c\/span\u003e\u003cspan\u003e and fitness center warm-water tanks where fossil-fuel combustion and flue-gas venting are prohibited or mechanically unfeasible.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\"\u003e\u003cspan\u003eOperating 45kW on a single-phase 240V supply demands substantial electrical infrastructure.\u003c\/span\u003e\u003cspan\u003e To manage terminal heat and comply with the National Electrical Code (NEC),\u003c\/span\u003e\u003cspan\u003e Coates utilizes a multi-stage magnetic contactor design with sub-divided internal heating banks.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eElectrical \u0026amp; Heating Performance\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eModel Designation:\u003c\/b\u003e\u003cspan\u003e Coates 12445CE \/ 12445CPH series.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eHeating Capacity:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"18\"\u003e45 kW (45,000 Watts)\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eThermal Output:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"16\"\u003e153,546 BTU\/hr\u003c\/b\u003e\u003cspan\u003e (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"45\\text{ kW} \\times 3,412.142\\text{ BTU\/kWh}\" data-index-in-node=\"32\"\u003e$45\\text{ kW} \\times 3,412.142\\text{ BTU\/kWh}$\u003c\/span\u003e\u003cspan\u003e).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eOperating Voltage:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"19\"\u003e240V AC\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"28\"\u003eSingle-Phase (1Ø)\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e 60 Hz.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\"\u003eFull Load Amperage (FLA):\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"26\"\u003e187.5 Amps\u003c\/b\u003e\u003cspan\u003e (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"45,000\\text{ W} \/ 240\\text{ V} = 187.5\\text{ A}\" data-index-in-node=\"38\"\u003e$45,000\\text{ W} \/ 240\\text{ V} = 187.5\\text{ A}$\u003c\/span\u003e\u003cspan\u003e).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,0\"\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"0\"\u003eOvercurrent Protection (Breaker Sizing):\u003c\/b\u003e\u003cspan\u003e Requires a total branch protection capacity of \u003c\/span\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"88\"\u003e235 to 250 Amps\u003c\/b\u003e\u003cspan\u003e under NEC 125% continuous-duty mandates (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"187.5\\text{ A} \\times 1.25 = 234.38\\text{ A}\" data-index-in-node=\"145\"\u003e$187.5\\text{ A} \\times 1.25 = 234.38\\text{ A}$\u003c\/span\u003e\u003cspan\u003e).\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"4,5,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,1,0,0\"\u003e\u003ci data-path-to-node=\"4,5,1,0,0\" data-index-in-node=\"0\"\u003eStandard Multi-Feed Branch Setup:\u003c\/i\u003e\u003cspan\u003e Single-phase loads of this magnitude cannot terminate safely on a single small contactor.\u003c\/span\u003e\u003cspan\u003e The unit is typically configured for \u003c\/span\u003e\u003cb data-path-to-node=\"4,5,1,0,0\" data-index-in-node=\"161\"\u003esplit multi-circuit supply\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"4,5,1,0,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,1,0,1,0,0\"\u003e\u003cb data-path-to-node=\"4,5,1,0,1,0,0\" data-index-in-node=\"0\"\u003eThree independent 80A \/ 2-Pole branch circuits\u003c\/b\u003e\u003cspan\u003e (each powering a 15kW element bank at 62.\u003c\/span\u003e\u003cspan\u003e5A continuous load:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"62.5\\text{ A} \\times 1.25 = 78.13\\text{ A}\" data-index-in-node=\"108\"\u003e$62.5\\text{ A} \\times 1.25 = 78.13\\text{ A}$\u003c\/span\u003e\u003cspan\u003e minimum breaker rating),\u003c\/span\u003e\u003cspan\u003e OR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,1,0,1,1,0\"\u003e\u003cb data-path-to-node=\"4,5,1,0,1,1,0\" data-index-in-node=\"0\"\u003eFour independent 60A \/ 2-Pole branch circuits\u003c\/b\u003e\u003cspan\u003e (depending on the internal element cluster division).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,6,0\"\u003e\u003cb data-path-to-node=\"4,6,0\" data-index-in-node=\"0\"\u003eConductor Sizing (Copper Only, 75°C\/90°C THHN\/THWN):\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"4,6,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,6,1,0,0\"\u003e\u003cb data-path-to-node=\"4,6,1,0,0\" data-index-in-node=\"0\"\u003eThree-Circuit Split:\u003c\/b\u003e\u003cspan\u003e Three independent runs of \u003c\/span\u003e\u003cb data-path-to-node=\"4,6,1,0,0\" data-index-in-node=\"47\"\u003e#3 AWG or #2 AWG copper\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,6,1,1,0\"\u003e\u003cb data-path-to-node=\"4,6,1,1,0\" data-index-in-node=\"0\"\u003eFour-Circuit Split:\u003c\/b\u003e\u003cspan\u003e Four independent runs of \u003c\/span\u003e\u003cb data-path-to-node=\"4,6,1,1,0\" data-index-in-node=\"45\"\u003e#6 AWG or #4 AWG copper\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,6,1,2,0\"\u003e\u003cb data-path-to-node=\"4,6,1,2,0\" data-index-in-node=\"0\"\u003eMain Subpanel Feeder (if feeding a local distribution panel):\u003c\/b\u003e\u003cspan\u003e Minimum \u003c\/span\u003e\u003cb data-path-to-node=\"4,6,1,2,0\" data-index-in-node=\"70\"\u003e250 kcmil or 300 kcmil copper\u003c\/b\u003e\u003cspan\u003e (or parallel runs) on a dedicated 250A distribution panelboard.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eConstruction \u0026amp; Safety Architecture\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003ePressure Vessel:\u003c\/b\u003e\u003cspan\u003e Heavy-gauge,\u003c\/span\u003e\u003cspan\u003e welded cylindrical steel\/stainless steel vessel with an internal protective baked lining engineered to resist erosion,\u003c\/span\u003e\u003cspan\u003e galvanic action,\u003c\/span\u003e\u003cspan\u003e and aggressive commercial chemical treatment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eHeating Elements:\u003c\/b\u003e\u003cspan\u003e Heavy-duty screw-plug immersion elements with low-watt-density \u003c\/span\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"81\"\u003eIncoloy 800\/825\u003c\/b\u003e\u003cspan\u003e or Titanium alloy sheathing to resist pitting,\u003c\/span\u003e\u003cspan\u003e scale buildup,\u003c\/span\u003e\u003cspan\u003e and high thermal stress.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eCabinet \u0026amp; Enclosure:\u003c\/b\u003e\u003cspan\u003e NEMA 1 industrial painted heavy-gauge steel cabinet with dual or full-front service doors for multi-stage contactor inspection,\u003c\/span\u003e\u003cspan\u003e wiring terminations,\u003c\/span\u003e\u003cspan\u003e and routine lug torque checks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eIntegrated Safety Controls:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"7,3,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,1,0,0\"\u003e\u003cspan\u003eDual-dial adjustable thermostatic controller calibrated up to 104°F (40°C) for commercial spa compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,1,1,0\"\u003e\u003cspan\u003eManual-reset High-Limit safety cutout set to de-energize control contactors at 122°F (50°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,1,2,0\"\u003e\u003cspan\u003eFlow\/pressure interlock switch preventing heating element contactors from pulling in during low-flow,\u003c\/span\u003e\u003cspan\u003e deadhead,\u003c\/span\u003e\u003cspan\u003e or pump shutdown conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eHydraulic \u0026amp; Plumbing Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003ePlumbing Connections:\u003c\/b\u003e\u003cspan\u003e Standard \u003c\/span\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"31\"\u003e1-1\/2\" NPT\u003c\/b\u003e\u003cspan\u003e female inlet and outlet ports (or flanged\/union adaptors for 2\" to 2-1\/2\" Schedule 80 CPVC headers).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eFlow Rate Parameters:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"10,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,1,0,0\"\u003e\u003cb data-path-to-node=\"10,1,1,0,0\" data-index-in-node=\"0\"\u003eMinimum Flow Rate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"10,1,1,0,0\" data-index-in-node=\"19\"\u003e25 to 30 GPM\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 95 to 114 LPM) required to satisfy the flow switch and prevent localized thermal cavitation\/boiling over the 45kW element bank.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,1,1,0\"\u003e\u003cb data-path-to-node=\"10,1,1,1,0\" data-index-in-node=\"0\"\u003eMaximum Flow Rate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"10,1,1,1,0\" data-index-in-node=\"19\"\u003e60 to 70 GPM\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 227 to 265 LPM); higher circulation filtration loops mandate an external plumbed bypass manifold.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eMaximum Working Pressure:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"26\"\u003e60 PSI\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 4.\u003c\/span\u003e\u003cspan\u003e14 bar).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"12\"\u003eDimensions, Net Weight \u0026amp; Shipping Weight\u003c\/h3\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eUnit Dimensions:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"31\"\u003e24.0\" L × 12.0\" W × 16.5\" H\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 61.\u003c\/span\u003e\u003cspan\u003e0 cm × 30.\u003c\/span\u003e\u003cspan\u003e5 cm × 41.\u003c\/span\u003e\u003cspan\u003e9 cm).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eNet Unit Weight:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"31\"\u003e82 to 90 lbs\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 37.\u003c\/span\u003e\u003cspan\u003e2 to 40.\u003c\/span\u003e\u003cspan\u003e8 kg).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003ePackaged Shipping Dimensions:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"44\"\u003e26\" L × 15\" W × 19\" H\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003ePackaged Shipping Weight:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"40\"\u003e96 to 108 lbs\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 43.\u003c\/span\u003e\u003cspan\u003e5 to 49.\u003c\/span\u003e\u003cspan\u003e0 kg) in reinforced corrugated packaging with dense molded foam inserts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eEstimated Temperature Rise Rates\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"16\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePool \/ Spa Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWater Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eApprox. Temperature Rise per Hour\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,1,0,0\"\u003e\u003cb data-path-to-node=\"16,1,0,0\" data-index-in-node=\"0\"\u003e500 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,1,1,0\"\u003e~4,170 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,1,2,0\"\u003e\u003cb data-path-to-node=\"16,1,2,0\" data-index-in-node=\"0\"\u003e36.8°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,2,0,0\"\u003e\u003cb data-path-to-node=\"16,2,0,0\" data-index-in-node=\"0\"\u003e1,000 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,2,1,0\"\u003e~8,340 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,2,2,0\"\u003e\u003cb data-path-to-node=\"16,2,2,0\" data-index-in-node=\"0\"\u003e18.4°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,3,0,0\"\u003e\u003cb data-path-to-node=\"16,3,0,0\" data-index-in-node=\"0\"\u003e2,500 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,3,1,0\"\u003e~20,850 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,3,2,0\"\u003e\u003cb data-path-to-node=\"16,3,2,0\" data-index-in-node=\"0\"\u003e7.4°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,4,0,0\"\u003e\u003cb data-path-to-node=\"16,4,0,0\" data-index-in-node=\"0\"\u003e5,000 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,4,1,0\"\u003e~41,700 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,4,2,0\"\u003e\u003cb data-path-to-node=\"16,4,2,0\" data-index-in-node=\"0\"\u003e3.7°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,5,0,0\"\u003e\u003cb data-path-to-node=\"16,5,0,0\" data-index-in-node=\"0\"\u003e10,000 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,5,1,0\"\u003e~83,400 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,5,2,0\"\u003e\u003cb data-path-to-node=\"16,5,2,0\" data-index-in-node=\"0\"\u003e1.8°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,6,0,0\"\u003e\u003cb data-path-to-node=\"16,6,0,0\" data-index-in-node=\"0\"\u003e15,000 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,6,1,0\"\u003e~125,100 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,6,2,0\"\u003e\u003cb data-path-to-node=\"16,6,2,0\" data-index-in-node=\"0\"\u003e1.2°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003ci data-path-to-node=\"17\" data-index-in-node=\"0\" class=\"\"\u003e(Calculation: \u003cspan class=\"math-inline\" data-math=\"\\text{Rise (°F\/hr)} = \\frac{153,546\\text{ BTU\/hr}}{\\text{Gallons} \\times 8.34\\text{ lbs\/gal}}\" data-index-in-node=\"14\"\u003e$\\text{Rise (°F\/hr)} = \\frac{153,546\\text{ BTU\/hr}}{\\text{Gallons} \\times 8.34\\text{ lbs\/gal}}$\u003c\/span\u003e, baseline heat-up rate assuming covered vessel without ambient radiation losses.)\u003c\/i\u003e\u003c\/p\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":68044289704047,"sku":"12445PHS","price":11373.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/JJ1241250_1-B.jpg?v=1793198106","url":"https:\/\/commercialpoolandspasupplies.com\/products\/coates-electric-pool-heater-45kw-240v-single-phase","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}