{"product_id":"coates-electric-pool-heater-54kw-240v-single-phase","title":"Coates Electric Pool Heater, 54kw 240V Single Phase","description":"\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003eCoates 54kW 240V Single-Phase Electric Pool \u0026amp; Spa Heater\u003c\/b\u003e\u003cspan\u003e (Model \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"68\"\u003e12454CE\u003c\/b\u003e\u003cspan\u003e \/ \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"78\"\u003e12454CPH\u003c\/b\u003e\u003cspan\u003e) represents the maximum heating envelope available in a single-phase commercial inline configuration.\u003c\/span\u003e\u003cspan\u003e Engineered for high-volume public therapy pools,\u003c\/span\u003e\u003cspan\u003e commercial resort swim spas,\u003c\/span\u003e\u003cspan\u003e wellness facilities,\u003c\/span\u003e\u003cspan\u003e and swim-school training tanks,\u003c\/span\u003e\u003cspan\u003e it provides extreme recovery capability in locations where natural gas venting is prohibited or physically impossible.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\"\u003e\u003cspan\u003eBecause a 54kW load on a 240V single-phase electrical service requires over 200 Amps of continuous current,\u003c\/span\u003e\u003cspan\u003e this unit utilizes internal bank segmentation with staged magnetic contactors,\u003c\/span\u003e\u003cspan\u003e designed specifically to be powered via multiple sub-divided branch circuits or a dedicated high-capacity distribution subpanel.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eElectrical \u0026amp; Heating Performance\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eModel Designation:\u003c\/b\u003e\u003cspan\u003e Coates 12454CE \/ 12454CPH series.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eHeating Capacity:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"18\"\u003e54 kW (54,000 Watts)\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eThermal Output:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"16\"\u003e184,256 BTU\/hr\u003c\/b\u003e\u003cspan\u003e (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"54\\text{ kW} \\times 3,412.142\\text{ BTU\/kWh}\" data-index-in-node=\"32\"\u003e$54\\text{ kW} \\times 3,412.142\\text{ BTU\/kWh}$\u003c\/span\u003e\u003cspan\u003e).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eOperating Voltage:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"19\"\u003e240V AC\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"28\"\u003eSingle-Phase (1Ø)\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e 60 Hz.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\"\u003eFull Load Amperage (FLA):\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"26\"\u003e225.0 Amps\u003c\/b\u003e\u003cspan\u003e (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"54,000\\text{ W} \/ 240\\text{ V} = 225.0\\text{ A}\" data-index-in-node=\"38\"\u003e$54,000\\text{ W} \/ 240\\text{ V} = 225.0\\text{ A}$\u003c\/span\u003e\u003cspan\u003e).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,0\"\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"0\"\u003eOvercurrent Protection (Breaker Sizing):\u003c\/b\u003e\u003cspan\u003e Requires a total branch protection capacity of \u003c\/span\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"88\"\u003e285 to 300 Amps\u003c\/b\u003e\u003cspan\u003e to comply with NEC 125% continuous-duty loading standards (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"225.0\\text{ A} \\times 1.25 = 281.25\\text{ A}\" data-index-in-node=\"163\"\u003e$225.0\\text{ A} \\times 1.25 = 281.25\\text{ A}$\u003c\/span\u003e\u003cspan\u003e).\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"4,5,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,1,0,0\"\u003e\u003ci data-path-to-node=\"4,5,1,0,0\" data-index-in-node=\"0\"\u003eStandard Multi-Feed Branch Architecture:\u003c\/i\u003e\u003cspan\u003e Because terminating 225A continuous on a single small terminal block is impractical,\u003c\/span\u003e\u003cspan\u003e the internal elements are split into staged sub-circuits:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"4,5,1,0,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,1,0,1,0,0\"\u003e\u003cb data-path-to-node=\"4,5,1,0,1,0,0\" data-index-in-node=\"0\"\u003eThree independent 100A \/ 2-Pole branch circuits\u003c\/b\u003e\u003cspan\u003e (each powering an 18kW element cluster at 75.\u003c\/span\u003e\u003cspan\u003e0A continuous load:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"75.0\\text{ A} \\times 1.25 = 93.75\\text{ A}\" data-index-in-node=\"113\"\u003e$75.0\\text{ A} \\times 1.25 = 93.75\\text{ A}$\u003c\/span\u003e\u003cspan\u003e minimum breaker rating),\u003c\/span\u003e\u003cspan\u003e OR\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,1,0,1,1,0\"\u003e\u003cb data-path-to-node=\"4,5,1,0,1,1,0\" data-index-in-node=\"0\"\u003eFour or more sub-divided branch circuits\u003c\/b\u003e\u003cspan\u003e (depending on internal factory contactor and terminal staging).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,6,0\"\u003e\u003cb data-path-to-node=\"4,6,0\" data-index-in-node=\"0\"\u003eConductor Sizing (Copper Only, 75°C\/90°C THHN\/THWN):\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"4,6,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,6,1,0,0\"\u003e\u003cb data-path-to-node=\"4,6,1,0,0\" data-index-in-node=\"0\"\u003eThree-Circuit Split:\u003c\/b\u003e\u003cspan\u003e Three independent runs of \u003c\/span\u003e\u003cb data-path-to-node=\"4,6,1,0,0\" data-index-in-node=\"47\"\u003e#1 AWG or #1\/0 AWG copper conductors\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,6,1,1,0\"\u003e\u003cb data-path-to-node=\"4,6,1,1,0\" data-index-in-node=\"0\"\u003eMain Subpanel Feeder (if feeding a dedicated localized panel):\u003c\/b\u003e\u003cspan\u003e Minimum \u003c\/span\u003e\u003cb data-path-to-node=\"4,6,1,1,0\" data-index-in-node=\"71\"\u003e300 kcmil or 350 kcmil copper\u003c\/b\u003e\u003cspan\u003e (or parallel runs) on a dedicated 300A distribution panelboard.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eConstruction \u0026amp; Safety Architecture\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003ePressure Vessel:\u003c\/b\u003e\u003cspan\u003e Heavy-gauge,\u003c\/span\u003e\u003cspan\u003e welded cylindrical steel\/stainless steel vessel with an internal protective baked coating engineered to resist erosion,\u003c\/span\u003e\u003cspan\u003e galvanic action,\u003c\/span\u003e\u003cspan\u003e and aggressive commercial chemical sanitizers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eHeating Elements:\u003c\/b\u003e\u003cspan\u003e Screw-plug immersion elements with heavy-duty \u003c\/span\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"64\"\u003eIncoloy 800\/825\u003c\/b\u003e\u003cspan\u003e or Titanium alloy sheathing to resist localized boiling pitting,\u003c\/span\u003e\u003cspan\u003e scaling,\u003c\/span\u003e\u003cspan\u003e and high thermal stress.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eCabinet \u0026amp; Enclosure:\u003c\/b\u003e\u003cspan\u003e NEMA 1 industrial painted heavy-gauge steel cabinet with full-front service access for multi-stage contactor inspection,\u003c\/span\u003e\u003cspan\u003e wiring terminations,\u003c\/span\u003e\u003cspan\u003e and routine terminal lug torque checks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eIntegrated Safety Controls:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"7,3,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,1,0,0\"\u003e\u003cspan\u003eDual-dial adjustable thermostatic controller calibrated up to 104°F (40°C) for commercial spa compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,1,1,0\"\u003e\u003cspan\u003eManual-reset High-Limit safety cutout set to de-energize control contactors at 122°F (50°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,1,2,0\"\u003e\u003cspan\u003eFlow\/pressure interlock switch preventing heating element contactors from pulling in during low-flow,\u003c\/span\u003e\u003cspan\u003e deadhead,\u003c\/span\u003e\u003cspan\u003e or pump shutdown conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eHydraulic \u0026amp; Plumbing Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003ePlumbing Connections:\u003c\/b\u003e\u003cspan\u003e Standard \u003c\/span\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"31\"\u003e1-1\/2\" NPT\u003c\/b\u003e\u003cspan\u003e female inlet and outlet ports (adapted via Schedule 80 unions into 2\",\u003c\/span\u003e\u003cspan\u003e 2-1\/2\",\u003c\/span\u003e\u003cspan\u003e or 3\" CPVC manifolds).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eFlow Rate Parameters:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"10,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,1,0,0\"\u003e\u003cb data-path-to-node=\"10,1,1,0,0\" data-index-in-node=\"0\"\u003eMinimum Flow Rate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"10,1,1,0,0\" data-index-in-node=\"19\"\u003e30 GPM\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 114 LPM) required to trip the flow switch and prevent localized thermal cavitation\/boiling over the dense 54kW element array.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,1,1,0\"\u003e\u003cb data-path-to-node=\"10,1,1,1,0\" data-index-in-node=\"0\"\u003eMaximum Flow Rate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"10,1,1,1,0\" data-index-in-node=\"19\"\u003e60 to 70 GPM\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 227 to 265 LPM); higher circulation filtration loops mandate an external plumbed bypass manifold.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eMaximum Working Pressure:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"26\"\u003e60 PSI\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 4.\u003c\/span\u003e\u003cspan\u003e14 bar).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"12\"\u003eDimensions, Net Weight \u0026amp; Shipping Weight\u003c\/h3\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eUnit Dimensions:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"31\"\u003e24.0\" L × 12.0\" W × 16.5\" H\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 61.\u003c\/span\u003e\u003cspan\u003e0 cm × 30.\u003c\/span\u003e\u003cspan\u003e5 cm × 41.\u003c\/span\u003e\u003cspan\u003e9 cm).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eNet Unit Weight:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"31\"\u003e88 to 96 lbs\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 39.\u003c\/span\u003e\u003cspan\u003e9 to 43.\u003c\/span\u003e\u003cspan\u003e5 kg).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003ePackaged Shipping Dimensions:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"44\"\u003e26\" L × 15\" W × 19\" H\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003ePackaged Shipping Weight:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"40\"\u003e102 to 114 lbs\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 46.\u003c\/span\u003e\u003cspan\u003e3 to 51.\u003c\/span\u003e\u003cspan\u003e7 kg) in heavy-duty reinforced corrugated packaging with dense molded foam inserts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eEstimated Temperature Rise Rates\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"16\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePool \/ Spa Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eWater Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eApprox. Temperature Rise per Hour\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,1,0,0\"\u003e\u003cb data-path-to-node=\"16,1,0,0\" data-index-in-node=\"0\"\u003e500 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,1,1,0\"\u003e~4,170 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,1,2,0\"\u003e\u003cb data-path-to-node=\"16,1,2,0\" data-index-in-node=\"0\"\u003e44.2°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,2,0,0\"\u003e\u003cb data-path-to-node=\"16,2,0,0\" data-index-in-node=\"0\"\u003e1,000 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,2,1,0\"\u003e~8,340 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,2,2,0\"\u003e\u003cb data-path-to-node=\"16,2,2,0\" data-index-in-node=\"0\"\u003e22.1°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,3,0,0\"\u003e\u003cb data-path-to-node=\"16,3,0,0\" data-index-in-node=\"0\"\u003e2,500 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,3,1,0\"\u003e~20,850 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,3,2,0\"\u003e\u003cb data-path-to-node=\"16,3,2,0\" data-index-in-node=\"0\"\u003e8.8°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,4,0,0\"\u003e\u003cb data-path-to-node=\"16,4,0,0\" data-index-in-node=\"0\"\u003e5,000 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,4,1,0\"\u003e~41,700 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,4,2,0\"\u003e\u003cb data-path-to-node=\"16,4,2,0\" data-index-in-node=\"0\"\u003e4.4°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,5,0,0\"\u003e\u003cb data-path-to-node=\"16,5,0,0\" data-index-in-node=\"0\"\u003e10,000 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,5,1,0\"\u003e~83,400 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,5,2,0\"\u003e\u003cb data-path-to-node=\"16,5,2,0\" data-index-in-node=\"0\"\u003e2.2°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,6,0,0\"\u003e\u003cb data-path-to-node=\"16,6,0,0\" data-index-in-node=\"0\"\u003e15,000 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,6,1,0\"\u003e~125,100 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,6,2,0\"\u003e\u003cb data-path-to-node=\"16,6,2,0\" data-index-in-node=\"0\"\u003e1.5°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,7,0,0\"\u003e\u003cb data-path-to-node=\"16,7,0,0\" data-index-in-node=\"0\"\u003e20,000 Gallons\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,7,1,0\"\u003e~166,800 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,7,2,0\"\u003e\u003cb data-path-to-node=\"16,7,2,0\" data-index-in-node=\"0\"\u003e1.1°F \/ hr\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003ci data-path-to-node=\"17\" data-index-in-node=\"0\" class=\"\"\u003e(Calculation: \u003cspan class=\"math-inline\" data-math=\"\\text{Rise (°F\/hr)} = \\frac{184,256\\text{ BTU\/hr}}{\\text{Gallons} \\times 8.34\\text{ lbs\/gal}}\" data-index-in-node=\"14\"\u003e$\\text{Rise (°F\/hr)} = \\frac{184,256\\text{ BTU\/hr}}{\\text{Gallons} \\times 8.34\\text{ lbs\/gal}}$\u003c\/span\u003e, baseline heat-up rate assuming covered vessel without ambient radiation losses.)\u003c\/i\u003e\u003c\/p\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":68044290195567,"sku":"12454PHS-4","price":12543.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/JJ1241250_1-B.jpg?v=1793198106","url":"https:\/\/commercialpoolandspasupplies.com\/products\/coates-electric-pool-heater-54kw-240v-single-phase","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}