{"product_id":"jandy-slip-style-3-contact-18-sensor-100-stand-pipe-install","title":"Jandy Slip Style 3 Contact-18\" Sensor 100', Stand-Pipe Install","description":"\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003eJandy Levolor S3040C18\u003c\/b\u003e\u003cspan\u003e (Part # \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"35\"\u003eR0658404\u003c\/b\u003e\u003cspan\u003e) is an 18-inch,\u003c\/span\u003e\u003cspan\u003e 3-contact slip-style electronic water level sensor assembly equipped with a \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"136\"\u003e100-foot cable\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cspan\u003e It is designed for vertical static standpipe installations and provides multi-level water sensing for advanced Levolor control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\"\u003e\u003cspan\u003eBy using three staggered stainless steel contacts rather than two,\u003c\/span\u003e\u003cspan\u003e the sensor monitors two independent water thresholds—typically paired with dual-action controllers such as the \u003c\/span\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"178\"\u003eK-2000\u003c\/b\u003e\u003cspan\u003e (normal fill plus high-water cutoff\/overflow relay) or \u003c\/span\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"240\"\u003eK-2100\u003c\/b\u003e\u003cspan\u003e (normal fill plus low-water pump cutoff protection).\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"attachment-container search-images md-has-block-component\"\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"5\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,0,0\"\u003e\u003cb data-path-to-node=\"5,1,0,0\" data-index-in-node=\"0\"\u003eModel \/ Part Number\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,1,1,0\"\u003e\u003cb data-path-to-node=\"5,1,1,0\" data-index-in-node=\"0\"\u003eS3040C18\u003c\/b\u003e \/ \u003cb data-path-to-node=\"5,1,1,0\" data-index-in-node=\"11\"\u003eR0658404\u003c\/b\u003e (also referenced as S-100-3-100)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,0,0\"\u003e\u003cb data-path-to-node=\"5,2,0,0\" data-index-in-node=\"0\"\u003eCable Length\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,2,1,0\"\u003e\u003cb data-path-to-node=\"5,2,1,0\" data-index-in-node=\"0\"\u003e100 ft\u003c\/b\u003e shielded, low-voltage direct-burial\/conduit lead\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,0,0\"\u003e\u003cb data-path-to-node=\"5,3,0,0\" data-index-in-node=\"0\"\u003eProbe Length \u0026amp; Style\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,3,1,0\"\u003e\u003cb data-path-to-node=\"5,3,1,0\" data-index-in-node=\"0\"\u003e18\"\u003c\/b\u003e rigid PVC slip-rod with 3 staggered stainless steel contact pins\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,0,0\"\u003e\u003cb data-path-to-node=\"5,4,0,0\" data-index-in-node=\"0\"\u003eContact Functions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,4,1,0\"\u003eCommon reference, normal fill cut-in\/cutoff, and secondary limit (High-Level or Low-Level Cutoff)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,0,0\"\u003e\u003cb data-path-to-node=\"5,5,0,0\" data-index-in-node=\"0\"\u003eMounting Format\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,5,1,0\"\u003eStandpipe installation (slides into a 1\" or 2\" PVC static pipe well)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,0,0\"\u003e\u003cb data-path-to-node=\"5,6,0,0\" data-index-in-node=\"0\"\u003eHardware Included\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,6,1,0\"\u003eCompression nut\/slip-adapter fitting for standpipe top\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,7,0,0\"\u003e\u003cb data-path-to-node=\"5,7,0,0\" data-index-in-node=\"0\"\u003eController Compatibility\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,7,1,0\"\u003eJandy Levolor \u003cb data-path-to-node=\"5,7,1,0\" data-index-in-node=\"14\"\u003eK-2000\u003c\/b\u003e (High Level \/ Fill) and \u003cb data-path-to-node=\"5,7,1,0\" data-index-in-node=\"45\"\u003eK-2100\u003c\/b\u003e (Low Level \/ Pump Cutoff) systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,8,0,0\"\u003e\u003cb data-path-to-node=\"5,8,0,0\" data-index-in-node=\"0\"\u003eShipping Weight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"5,8,1,0\"\u003e\u003cb data-path-to-node=\"5,8,1,0\" data-index-in-node=\"0\"\u003e~5.5 to 6.0 lbs\u003c\/b\u003e (reflects the 100-foot shielded spool, 18\" probe, and compression fitting)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"7\"\u003eStandpipe Installation Summary\u003c\/h3\u003e\n\u003col start=\"1\" data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eStatic Pipe Setup:\u003c\/b\u003e\u003cspan\u003e Plumb a vertical PVC pipe (1\" or 2\") tied into the pool equalizer line or main drain plumbing below the operational waterline to provide an undisturbed,\u003c\/span\u003e\u003cspan\u003e wave-damped water column.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eMount Slip Collar:\u003c\/b\u003e\u003cspan\u003e Solvent-weld the included compression housing adapter fitting directly onto the top rim of the standpipe.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eCalibrate Sensing Depth:\u003c\/b\u003e\u003cspan\u003e Slide the 18-inch probe down into the tube until the contacts sit at your target elevations (the lowest contact serves as the reference ground,\u003c\/span\u003e\u003cspan\u003e while the upper pins trigger fill and safety alarm thresholds).\u003c\/span\u003e\u003cspan\u003e Hand-tighten the compression nut to secure depth.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eRun Wiring:\u003c\/b\u003e\u003cspan\u003e Pull the 100-foot shielded lead through dedicated low-voltage electrical conduit back to the equipment pad and connect the three conductors to the designated sensor terminals on the Levolor circuit board.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":68128574734447,"sku":"S3040C18","price":305.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/Jandy-Slip-Style-2-Stand-Pipe-Install-Contact-Sensor-with-100-Cord-S2040C_d2c92ca6-6c61-4027-9c64-ff1c6708c09d.979991b9b8be6c9660db53bb63f452fc.avif?v=1793635510","url":"https:\/\/commercialpoolandspasupplies.com\/products\/jandy-slip-style-3-contact-18-sensor-100-stand-pipe-install","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}