{"product_id":"link-automation-conx-connector-cable","title":"LINK AUTOMATION, CONX CONNECTOR CABLE","description":"\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003eLink Automation CONX Connector Cable\u003c\/b\u003e\u003cspan class=\"\"\u003e (Pool Link \/ Link Automation) is a heavy-duty,\u003c\/span\u003e\u003cspan\u003e water-tight shielded instrumentation extension and interconnect cable assembly engineered for commercial pool,\u003c\/span\u003e\u003cspan\u003e spa,\u003c\/span\u003e\u003cspan\u003e and industrial water chemistry automation systems.\u003c\/span\u003e\u003cspan\u003e Specifically designed for high-humidity,\u003c\/span\u003e\u003cspan\u003e chemically aggressive pump rooms and natatorium mechanical spaces,\u003c\/span\u003e\u003cspan class=\"\"\u003e this cable utilizes circular industrial \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"403\"\u003eCONX\u003c\/b\u003e\u003cspan\u003e (sealed multi-pin) connectors to provide an IP67\/NEMA 6P rated,\u003c\/span\u003e\u003cspan\u003e submersible-capable physical connection that eliminates the pin corrosion,\u003c\/span\u003e\u003cspan\u003e moisture intrusion,\u003c\/span\u003e\u003cspan\u003e and microvolt signal drift common to unsealed connectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eHardware \u0026amp; Analytical Architecture\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan\u003eEngineered to preserve ultra-low millivolt (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"mV\" data-index-in-node=\"44\"\u003e$mV$\u003c\/span\u003e\u003cspan\u003e) potential signals from glass combination pH probes,\u003c\/span\u003e\u003cspan\u003e platinum\/gold ORP sensors,\u003c\/span\u003e\u003cspan\u003e and solid-state temperature probes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eWater-Tight Circular CONX Interface:\u003c\/b\u003e\u003cspan\u003e Uses a circular,\u003c\/span\u003e\u003cspan\u003e molded industrial connector with positive bayonet or threaded locking collars and internal fluorocarbon\/nitrile elastomeric O-rings.\u003c\/span\u003e\u003cspan\u003e The keyed shell ensures correct pin alignment,\u003c\/span\u003e\u003cspan\u003e and the environmental seal prevents corrosive chloramines,\u003c\/span\u003e\u003cspan\u003e acid fumes,\u003c\/span\u003e\u003cspan\u003e condensation,\u003c\/span\u003e\u003cspan\u003e and washdown spray from degrading contact surfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eHigh-Impedance Signal Preservation:\u003c\/b\u003e\u003cspan\u003e pH glass membranes exhibit extreme internal resistance (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"10\\text{ M}\\Omega\" data-index-in-node=\"92\"\u003e$10\\text{ M}\\Omega$\u003c\/span\u003e\u003cspan\u003e to \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"1,000\\text{ M}\\Omega\" data-index-in-node=\"113\"\u003e$1,000\\text{ M}\\Omega$\u003c\/span\u003e\u003cspan\u003e).\u003c\/span\u003e\u003cspan\u003e The cable utilizes high-purity polyethylene or PTFE core dielectric insulation with an ultra-low dielectric constant,\u003c\/span\u003e\u003cspan\u003e minimizing capacitive signal loss and preventing triboelectric\/microphonic noise spikes caused by cable vibration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eDouble-Shielded Low-Noise Construction:\u003c\/b\u003e\u003cspan\u003e Built with an inner conductive carbon\/polyester layer wrapped in a high-coverage tinned copper braided shield (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"\u0026gt;95\\%\" data-index-in-node=\"151\"\u003e$\u0026gt;95\\%$\u003c\/span\u003e\u003cspan\u003e optical coverage).\u003c\/span\u003e\u003cspan\u003e This design suppresses electromagnetic interference (EMI) and radio frequency interference (RFI) emitted by adjacent variable frequency drives (VFDs),\u003c\/span\u003e\u003cspan\u003e commercial pump motors,\u003c\/span\u003e\u003cspan\u003e and chemical dosing contactors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eHeavy-Duty Chemical-Resistant Jacket:\u003c\/b\u003e\u003cspan\u003e Encased in a rugged,\u003c\/span\u003e\u003cspan\u003e oil- and chemical-resistant thermoplastic elastomer (TPE) or specialized PVC outer jacket designed to resist cracking,\u003c\/span\u003e\u003cspan\u003e ozone,\u003c\/span\u003e\u003cspan\u003e UV exposure,\u003c\/span\u003e\u003cspan\u003e and direct chemical contact in mechanical rooms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\"\u003eIntegrated Molded Strain Relief:\u003c\/b\u003e\u003cspan\u003e Overmolded backshells absorb mechanical pulling and bending stress,\u003c\/span\u003e\u003cspan\u003e preventing fatigue failure and conductor shearing at the connector termination points.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eCable Configuration:\u003c\/b\u003e\u003cspan\u003e Multi-conductor or coaxial low-noise shielded instrumentation cable with internal drain wire.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eTermination Configurations:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"7,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,1,0,0\"\u003e\u003cb data-path-to-node=\"7,1,1,0,0\" data-index-in-node=\"0\"\u003eCONX Male to CONX Female:\u003c\/b\u003e\u003cspan class=\"\"\u003e Direct in-line extension cable to lengthen factory sensor leads to distant wall panels or secondary enclosures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,1,1,0\"\u003e\u003cb data-path-to-node=\"7,1,1,1,0\" data-index-in-node=\"0\"\u003eCONX Female to Stripped \u0026amp; Tinned Leads:\u003c\/b\u003e\u003cspan class=\"\"\u003e Panel-mount or field-wiring harness linking a CONX probe to internal terminal blocks on controller circuit boards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,1,2,0\"\u003e\u003cb data-path-to-node=\"7,1,1,2,0\" data-index-in-node=\"0\"\u003eCONX Female to BNC Male (Adapter Configuration):\u003c\/b\u003e\u003cspan\u003e Interface cable enabling a CONX-terminated probe to plug directly into legacy controllers equipped only with standard BNC jacks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eStandard Cable Lengths:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"7,2,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,1,0,0\"\u003e\u003cb data-path-to-node=\"7,2,1,0,0\" data-index-in-node=\"0\"\u003e10-foot\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 3.\u003c\/span\u003e\u003cspan\u003e0 m) – Standard panel\/bypass connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,1,1,0\"\u003e\u003cb data-path-to-node=\"7,2,1,1,0\" data-index-in-node=\"0\"\u003e20-foot\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 6.\u003c\/span\u003e\u003cspan\u003e1 m) – Extended mechanical room routing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,1,2,0\"\u003e\u003cb data-path-to-node=\"7,2,1,2,0\" data-index-in-node=\"0\"\u003e30-foot\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 9.\u003c\/span\u003e\u003cspan\u003e1 m) – Remote panel installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eIngress Protection Rating:\u003c\/b\u003e\u003cspan\u003e IP67 \/ NEMA 6P (when properly mated and locked).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eOperating Temperature Limits:\u003c\/b\u003e\u003cspan\u003e -4°F to 158°F (-20°C to 70°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eRated Voltage \/ Signal Range:\u003c\/b\u003e\u003cspan\u003e Low-voltage analog signals from \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"\\pm 2,000\\text{ mV DC}\" data-index-in-node=\"62\"\u003e$\\pm 2,000\\text{ mV DC}$\u003c\/span\u003e\u003cspan\u003e up to 30V AC\/DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eInstallation \u0026amp; Field Routing Best Practices\u003c\/h3\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eSeparate Conduit Runs:\u003c\/b\u003e\u003cspan\u003e Always pull CONX low-voltage sensor cables through dedicated,\u003c\/span\u003e\u003cspan\u003e isolated low-voltage conduit.\u003c\/span\u003e\u003cspan\u003e Never route sensor lines in the same conduit,\u003c\/span\u003e\u003cspan\u003e wire duct,\u003c\/span\u003e\u003cspan\u003e or pull box as high-voltage AC feeds (115V \/ 230V \/ 460V),\u003c\/span\u003e\u003cspan\u003e motor leads,\u003c\/span\u003e\u003cspan\u003e or feed pump wiring to prevent induced AC ripple.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eDo Not Field-Splice:\u003c\/b\u003e\u003cspan\u003e Never cut,\u003c\/span\u003e\u003cspan\u003e strip,\u003c\/span\u003e\u003cspan\u003e or splice a CONX cable using standard wire nuts or unshielded junction blocks.\u003c\/span\u003e\u003cspan\u003e Field splices break the continuous shield,\u003c\/span\u003e\u003cspan\u003e alter cable capacitance,\u003c\/span\u003e\u003cspan\u003e introduce ground loops,\u003c\/span\u003e\u003cspan\u003e and cause erratic pH\/ORP readings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eConnector Care:\u003c\/b\u003e\u003cspan\u003e Before mating,\u003c\/span\u003e\u003cspan\u003e verify that the internal alignment key and slot match.\u003c\/span\u003e\u003cspan\u003e Hand-tighten the circular locking ring until it firmly seats against its internal O-ring stop.\u003c\/span\u003e\u003cspan\u003e Never use pliers or pipe wrenches on plastic locking rings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":67968892174447,"sku":"X\/B-010","price":279.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/gain-express-e-2627-e-2627-ph-probe-with-bnc-connector-150cm-long-cable-0-14ph-test-sensor-electrode-for-ph-meter-monitor-controller-replacement-kit-for.webp?v=1792680306","url":"https:\/\/commercialpoolandspasupplies.com\/products\/link-automation-conx-connector-cable","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}