{"product_id":"link-automation-orp-probe-with-bnc-connector-cable","title":"LINK AUTOMATION, ORP PROBE WITH BNC CONNECTOR CABLE","description":"\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003eLink Automation ORP Probe with BNC Connector Cable\u003c\/b\u003e\u003cspan class=\"\"\u003e (Pool Link \/ Link Automation) is a heavy-duty,\u003c\/span\u003e\u003cspan\u003e commercial-grade oxidation-reduction potential electrode engineered for commercial swimming pool,\u003c\/span\u003e\u003cspan\u003e spa,\u003c\/span\u003e\u003cspan class=\"\"\u003e and water treatment automation systems.\u003c\/span\u003e\u003cspan\u003e It measures the net oxidizing\/reducing power of the water to quantify sanitizer activity (free chlorine,\u003c\/span\u003e\u003cspan\u003e bromine,\u003c\/span\u003e\u003cspan\u003e or ozone) in millivolts (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"mV\" data-index-in-node=\"384\"\u003e$mV$\u003c\/span\u003e\u003cspan\u003e),\u003c\/span\u003e\u003cspan\u003e transmitting the signal to the controller via a low-noise,\u003c\/span\u003e\u003cspan\u003e shielded coaxial cable terminated with a standard BNC connector.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"1\"\u003eHardware \u0026amp; Analytical Architecture\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cspan\u003eDesigned to withstand continuous immersion in aggressive,\u003c\/span\u003e\u003cspan\u003e chemically treated commercial aquatic environments:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHigh-Purity Platinum Sensing Surface:\u003c\/b\u003e\u003cspan\u003e Features a solid platinum band or disc tip that provides rapid electron exchange with chemical oxidizers in the sample stream,\u003c\/span\u003e\u003cspan\u003e delivering immediate response to residual fluctuations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eSealed Reference Chamber:\u003c\/b\u003e\u003cspan\u003e Contains a gelled silver\/silver chloride (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"Ag\/AgCl\" data-index-in-node=\"68\"\u003e$Ag\/AgCl$\u003c\/span\u003e\u003cspan\u003e) reference electrolyte system that requires no liquid refills or pressurization during routine service.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003ePorous Annular Junction:\u003c\/b\u003e\u003cspan\u003e Outfitted with a porous Teflon or ceramic junction that resists fouling from suspended solids,\u003c\/span\u003e\u003cspan\u003e bather oils,\u003c\/span\u003e\u003cspan\u003e and mineral scale while maintaining steady electrical contact with the water stream.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eLow-Noise Shielded Coax:\u003c\/b\u003e\u003cspan\u003e Heavy-gauge,\u003c\/span\u003e\u003cspan\u003e double-shielded coaxial cable engineered to suppress electromagnetic interference (EMI) and radio-frequency noise from variable frequency drives (VFDs),\u003c\/span\u003e\u003cspan\u003e large circulation pump motors,\u003c\/span\u003e\u003cspan\u003e and high-voltage feeder relays.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\" class=\"\"\u003eCorrosion-Resistant BNC Connector:\u003c\/b\u003e\u003cspan\u003e Terminated with a nickel- or gold-plated BNC plug protected by an integrated rubber\/silicone boot to guard against corrosion in humid,\u003c\/span\u003e\u003cspan\u003e chloramine-rich chemical rooms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,5,0\"\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003eProtective Storage Boot:\u003c\/b\u003e\u003cspan\u003e Ships pre-hydrated with a wetting cap filled with 3.\u003c\/span\u003e\u003cspan\u003e8 M or 4.\u003c\/span\u003e\u003cspan\u003e0 M potassium chloride (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"KCl\" data-index-in-node=\"110\"\u003e$KCl$\u003c\/span\u003e\u003cspan\u003e) storage solution to protect the reference junction during storage and transit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eMeasurement Range:\u003c\/b\u003e\u003cspan\u003e 0 to 1,\u003c\/span\u003e\u003cspan\u003e000 mV (full operating potential typically -1,\u003c\/span\u003e\u003cspan\u003e000 to +1,\u003c\/span\u003e\u003cspan\u003e000 mV).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eReference System:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"Ag\/AgCl\" data-index-in-node=\"18\"\u003e$Ag\/AgCl$\u003c\/span\u003e\u003cspan\u003e with gelled electrolyte.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eResponse Time:\u003c\/b\u003e\u003cspan\u003e Reaches \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"90\\%\" data-index-in-node=\"23\"\u003e$90\\%$\u003c\/span\u003e\u003cspan\u003e of final stabilized reading within \u003c\/span\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"63\"\u003e3 to 10 seconds\u003c\/b\u003e\u003cspan\u003e in an active flow stream.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eOperating Temperature Range:\u003c\/b\u003e\u003cspan\u003e 32°F to 140°F (0°C to 60°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eMaximum Operating Pressure:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"28\"\u003e50 PSI\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 3.\u003c\/span\u003e\u003cspan\u003e45 bar) in commercial flow cell manifolds.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eProcess Mounting Connection:\u003c\/b\u003e\u003cspan\u003e 1\/2\" NPT or 3\/4\" NPT threaded body \/ compression collar gland mount (direct fit for Pool Link 500 Series,\u003c\/span\u003e\u003cspan\u003e Legacy chambers,\u003c\/span\u003e\u003cspan\u003e and Hayward CAT flow cells).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eCable Length:\u003c\/b\u003e\u003cspan\u003e Standard \u003c\/span\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"23\"\u003e10-foot\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 3.\u003c\/span\u003e\u003cspan\u003e0 m) lead (with optional 20-foot or 30-foot variants for remote panel mounts).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eMaintenance, Cleaning \u0026amp; Calibration Protocols\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eStorage Protocol:\u003c\/b\u003e\u003cspan\u003e Keep the reference junction wet at all times.\u003c\/span\u003e\u003cspan\u003e Store in 4.\u003c\/span\u003e\u003cspan\u003e0 M KCl solution (or pool water in a temporary pinch).\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"130\"\u003eNever store in pure distilled or deionized water\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e as this leaches reference electrolytes out through the porous junction.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003ePlatinum Cleaning:\u003c\/b\u003e\u003cspan\u003e Remove mineral scaling or organic oil film by soaking the tip in a 5% to 10% hydrochloric acid solution or household vinegar for 5 to 10 minutes.\u003c\/span\u003e\u003cspan\u003e If the platinum band is passivated or coated with bio-film,\u003c\/span\u003e\u003cspan\u003e gently swab the metal surface with a soft cotton swab dipped in isopropyl alcohol or a mild abrasive slurry (such as toothpaste or liquid dish soap),\u003c\/span\u003e\u003cspan\u003e followed by a clean water rinse.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eCalibration \u0026amp; Verification:\u003c\/b\u003e\u003cspan\u003e Verified using standard quinhydrone reference solutions (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"pH\\ 4.00\" data-index-in-node=\"85\"\u003e$pH\\ 4.00$\u003c\/span\u003e\u003cspan\u003e buffer saturated with quinhydrone yields approx.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"+263\\text{ mV}\" data-index-in-node=\"143\"\u003e$+263\\text{ mV}$\u003c\/span\u003e\u003cspan\u003e at 25°C; \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"pH\\ 7.00\" data-index-in-node=\"167\"\u003e$pH\\ 7.00$\u003c\/span\u003e\u003cspan\u003e buffer with quinhydrone yields approx.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"+86\\text{ mV}\" data-index-in-node=\"215\"\u003e$+86\\text{ mV}$\u003c\/span\u003e\u003cspan\u003e).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":67968853442671,"sku":"PROBE-ORP-BNC","price":1055.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/gain-express-e-2627-e-2627-ph-probe-with-bnc-connector-150cm-long-cable-0-14ph-test-sensor-electrode-for-ph-meter-monitor-controller-replacement-kit-for.webp?v=1792680306","url":"https:\/\/commercialpoolandspasupplies.com\/products\/link-automation-orp-probe-with-bnc-connector-cable","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}