{"product_id":"link-automation-orp-probe-with-conx-connector-cable-gold-tipped","title":"LINK AUTOMATION, ORP PROBE WITH CONX CONNECTOR CABLE, GOLD TIPPED","description":"\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\" class=\"\"\u003eLink Automation ORP Probe with CONX Connector Cable, Gold Tipped\u003c\/b\u003e\u003cspan\u003e (Pool Link \/ Link Automation) is a specialized commercial-grade oxidation-reduction potential electrode engineered specifically for commercial aquatic facilities utilizing \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"241\" class=\"\"\u003esalt chlorine generation (electrolytic chlorinators)\u003c\/b\u003e\u003cspan class=\"\"\u003e or ozone systems in high-humidity,\u003c\/span\u003e\u003cspan\u003e corrosive chemical room environments.\u003c\/span\u003e\u003cspan\u003e Combining a solid gold sensing tip with an industrial CONX circular connector,\u003c\/span\u003e\u003cspan\u003e this configuration eliminates hydrogen gas interference on the sensing face while providing an IP67\/NEMA 6P sealed,\u003c\/span\u003e\u003cspan\u003e water-tight physical lock at the controller enclosure bulkhead to prevent pin corrosion and signal loss.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"1\"\u003eHardware \u0026amp; Analytical Architecture\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cspan\u003eEngineered to maintain precision millivolt (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"mV\" data-index-in-node=\"44\"\u003e$mV$\u003c\/span\u003e\u003cspan\u003e) potential measurements across aggressive commercial turnover cycles:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHigh-Purity Solid Gold (Au) Tip:\u003c\/b\u003e\u003cspan\u003e Designed specifically for electrolytic saltwater applications.\u003c\/span\u003e\u003cspan\u003e Electrolytic cells generate microscopic hydrogen bubbles at the cathode that adsorb onto traditional platinum bands,\u003c\/span\u003e\u003cspan\u003e depressing millivolt readings (hydrogen overpotential).\u003c\/span\u003e\u003cspan\u003e Gold features a significantly higher hydrogen overpotential,\u003c\/span\u003e\u003cspan\u003e resisting gas blinding and providing stable,\u003c\/span\u003e\u003cspan\u003e accurate ORP tracking in saltwater pools.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eIndustrial CONX Water-Tight Termination:\u003c\/b\u003e\u003cspan\u003e Replaces standard exposed BNC plugs with a molded circular multi-pin connector featuring internal elastomeric O-rings and a threaded or bayonet locking collar.\u003c\/span\u003e\u003cspan\u003e This design creates a hermetic seal against airborne acid vapors,\u003c\/span\u003e\u003cspan\u003e chloramine gas,\u003c\/span\u003e\u003cspan\u003e and washdown spray,\u003c\/span\u003e\u003cspan\u003e eliminating high-resistance contact faults and ground loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\" class=\"\"\u003eSealed \u003cspan class=\"math-inline\" data-math=\"Ag\/AgCl\" data-index-in-node=\"7\"\u003e$Ag\/AgCl$\u003c\/span\u003e Reference System:\u003c\/b\u003e\u003cspan\u003e Outfitted with an internal silver\/silver chloride reference electrode suspended in a high-viscosity,\u003c\/span\u003e\u003cspan\u003e saturated potassium chloride (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"KCl\" data-index-in-node=\"164\"\u003e$KCl$\u003c\/span\u003e\u003cspan\u003e) gel matrix that requires no ongoing pressurization or electrolyte replenishment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003ePorous Liquid Junction:\u003c\/b\u003e\u003cspan\u003e Features a broad-surface porous Teflon or ceramic annular junction designed to resist fouling from suspended bather organics,\u003c\/span\u003e\u003cspan\u003e oils,\u003c\/span\u003e\u003cspan\u003e and calcium carbonate scale while maintaining steady electrolytic continuity with the sample stream.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eShielded Low-Noise Coaxial Cable:\u003c\/b\u003e\u003cspan\u003e Wrapped in heavy-gauge,\u003c\/span\u003e\u003cspan\u003e double-shielded jacketing engineered to suppress electromagnetic interference (EMI) and radio-frequency noise emitted by adjacent variable frequency drives (VFDs),\u003c\/span\u003e\u003cspan\u003e electronic salt chlorinator power supplies,\u003c\/span\u003e\u003cspan\u003e and high-voltage pump motors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,5,0\"\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003eProtective Storage Boot:\u003c\/b\u003e\u003cspan\u003e Ships pre-hydrated with a liquid-tight storage cap filled with 3.\u003c\/span\u003e\u003cspan\u003e8 M or 4.\u003c\/span\u003e\u003cspan\u003e0 M potassium chloride (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"KCl\" data-index-in-node=\"123\"\u003e$KCl$\u003c\/span\u003e\u003cspan\u003e) storage buffer to protect the reference junction during storage and transit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eMeasurement Range:\u003c\/b\u003e\u003cspan\u003e 0 to 1,\u003c\/span\u003e\u003cspan\u003e000 mV (nominal operational window:\u003c\/span\u003e\u003cspan\u003e -1,\u003c\/span\u003e\u003cspan\u003e000 to +1,\u003c\/span\u003e\u003cspan\u003e000 mV).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eReference System:\u003c\/b\u003e\u003cspan\u003e Sealed \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"Ag\/AgCl\" data-index-in-node=\"25\"\u003e$Ag\/AgCl$\u003c\/span\u003e\u003cspan\u003e with gelled electrolyte.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eApplication Suitability:\u003c\/b\u003e\u003cspan\u003e Commercial saltwater chlorination systems,\u003c\/span\u003e\u003cspan\u003e ozone contact systems,\u003c\/span\u003e\u003cspan\u003e and standard liquid hypochlorite applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eResponse Dynamic:\u003c\/b\u003e\u003cspan\u003e Achieves \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"90\\%\" data-index-in-node=\"27\"\u003e$90\\%$\u003c\/span\u003e\u003cspan\u003e of stabilized millivolt equilibrium within \u003c\/span\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"75\"\u003e3 to 10 seconds\u003c\/b\u003e\u003cspan\u003e in active bypass flow.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eConnector Type:\u003c\/b\u003e\u003cspan\u003e Molded CONX circular quick-disconnect connector with threaded\/bayonet locking collar.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eCable Length:\u003c\/b\u003e\u003cspan\u003e Standard \u003c\/span\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"23\"\u003e10-foot\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 3.\u003c\/span\u003e\u003cspan\u003e0 m) lead (optional 20-foot or 30-foot extended factory leads available for remote panel routing).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eOperating Temperature Limits:\u003c\/b\u003e\u003cspan\u003e 32°F to 140°F (0°C to 60°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eMaximum Working Pressure:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"26\"\u003e50 PSI\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 3.\u003c\/span\u003e\u003cspan\u003e45 bar) in commercial flow cell manifolds.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,8,0\"\u003e\u003cb data-path-to-node=\"6,8,0\" data-index-in-node=\"0\"\u003eProcess Connection Fitting:\u003c\/b\u003e\u003cspan\u003e 1\/2\" NPT or 3\/4\" NPT external body threads \/ compression gland mount (fits Pool Link 500 Series,\u003c\/span\u003e\u003cspan\u003e Legacy chambers,\u003c\/span\u003e\u003cspan\u003e and Hayward CAT acrylic flow cells).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eCalibration, Cleaning \u0026amp; Maintenance\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eHydration Protocol:\u003c\/b\u003e\u003cspan\u003e The gold tip and porous junction must remain wet at all times.\u003c\/span\u003e\u003cspan\u003e When taking the sampling loop off-line for winterization or plumbing repairs,\u003c\/span\u003e\u003cspan\u003e reinstall the wetting boot filled with 4.\u003c\/span\u003e\u003cspan\u003e0 M KCl solution (or clean pool water in an emergency).\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"258\"\u003eNever store the probe in distilled or deionized water\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e as zero-ion water rapidly leaches reference ions out through the porous junction.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eGold Tip Cleaning:\u003c\/b\u003e\u003cspan\u003e Avoid abrasive scouring pads or sandpaper on gold tips.\u003c\/span\u003e\u003cspan\u003e Remove organic bio-films or bather oils by gently wiping the gold surface with a soft cotton swab saturated with isopropyl alcohol or mild liquid detergent.\u003c\/span\u003e\u003cspan\u003e For mineral scale,\u003c\/span\u003e\u003cspan\u003e soak the tip in a 5% to 10% hydrochloric acid solution or household white vinegar for 5 to 10 minutes,\u003c\/span\u003e\u003cspan\u003e followed by a thorough tap water rinse.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eCalibration \u0026amp; Verification:\u003c\/b\u003e\u003cspan\u003e Verified using standard quinhydrone redox reference buffers (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"pH\\ 4.00\" data-index-in-node=\"89\"\u003e$pH\\ 4.00$\u003c\/span\u003e\u003cspan\u003e buffer saturated with quinhydrone yields approximately \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"+263\\text{ mV}\" data-index-in-node=\"153\"\u003e$+263\\text{ mV}$\u003c\/span\u003e\u003cspan\u003e at 25°C; \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"pH\\ 7.00\" data-index-in-node=\"177\"\u003e$pH\\ 7.00$\u003c\/span\u003e\u003cspan\u003e buffer with quinhydrone yields approximately \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"+86\\text{ mV}\" data-index-in-node=\"231\"\u003e$+86\\text{ mV}$\u003c\/span\u003e\u003cspan\u003e).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":67968885915759,"sku":"PROBE-ORP-GOLD-C","price":1245.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/gain-express-e-2627-e-2627-ph-probe-with-bnc-connector-150cm-long-cable-0-14ph-test-sensor-electrode-for-ph-meter-monitor-controller-replacement-kit-for.webp?v=1792680306","url":"https:\/\/commercialpoolandspasupplies.com\/products\/link-automation-orp-probe-with-conx-connector-cable-gold-tipped","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}