{"product_id":"link-automation-ph-probe-with-bnc-connector-cable","title":"LINK AUTOMATION, pH PROBE WITH BNC CONNECTOR CABLE","description":"\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\" class=\"\"\u003eLink Automation pH Probe with BNC Connector Cable\u003c\/b\u003e\u003cspan class=\"\"\u003e (Pool Link \/ Link Automation) is a heavy-duty,\u003c\/span\u003e\u003cspan\u003e commercial-grade combination electrode engineered for automated commercial pool,\u003c\/span\u003e\u003cspan\u003e spa,\u003c\/span\u003e\u003cspan\u003e and water treatment chemistry controllers.\u003c\/span\u003e\u003cspan class=\"\"\u003e Designed to measure hydronium ion activity (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"H^+\" data-index-in-node=\"274\"\u003e$H^+$\u003c\/span\u003e\u003cspan\u003e) in recirculating water,\u003c\/span\u003e\u003cspan\u003e it translates chemical balance into a millivolt (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"mV\" data-index-in-node=\"352\"\u003e$mV$\u003c\/span\u003e\u003cspan\u003e) potential transmitted directly to the controller console via a shielded,\u003c\/span\u003e\u003cspan\u003e low-noise coaxial cable terminated with a moisture-resistant BNC connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"1\"\u003eHardware \u0026amp; Analytical Architecture\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cspan\u003eBuilt to withstand continuous exposure to chlorinated water,\u003c\/span\u003e\u003cspan\u003e variable bather loads,\u003c\/span\u003e\u003cspan\u003e and broad pH swings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eCombination Measurement System:\u003c\/b\u003e\u003cspan\u003e Integrates the measuring glass electrode and reference half-cell into a single,\u003c\/span\u003e\u003cspan\u003e compact body.\u003c\/span\u003e\u003cspan\u003e The inner reference cell uses a silver\/silver chloride (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"Ag\/AgCl\" data-index-in-node=\"182\"\u003e$Ag\/AgCl$\u003c\/span\u003e\u003cspan\u003e) half-cell suspended in a saturated gelled electrolyte.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003ePorous Liquid Junction:\u003c\/b\u003e\u003cspan\u003e Features a porous Teflon or ceramic annular liquid junction that provides low electrical resistance while minimizing electrolyte fouling,\u003c\/span\u003e\u003cspan\u003e chemical poisoning,\u003c\/span\u003e\u003cspan\u003e and clogging from suspended solids or calcium scaling.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eShielded Coaxial Cabling:\u003c\/b\u003e\u003cspan\u003e Encased in heavy-gauge,\u003c\/span\u003e\u003cspan\u003e low-noise shielded coaxial cable designed to reject electromagnetic interference (EMI) and radio-frequency interference (RFI) generated by nearby variable-frequency drives (VFDs),\u003c\/span\u003e\u003cspan\u003e commercial pump motors,\u003c\/span\u003e\u003cspan class=\"\"\u003e and chemical feed solenoids.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCorrosion-Proof BNC Connector:\u003c\/b\u003e\u003cspan class=\"\"\u003e Terminated with a nickel-plated or gold-flashed BNC plug featuring an integrated rubber\/silicone moisture boot to prevent moisture creep and terminal corrosion in humid chemical rooms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eProtective Storage Boot:\u003c\/b\u003e\u003cspan\u003e Ships pre-hydrated in a threaded or slip-on wetting boot filled with a 3.\u003c\/span\u003e\u003cspan\u003e8 M or 4.\u003c\/span\u003e\u003cspan\u003e0 M potassium chloride (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"KCl\" data-index-in-node=\"131\"\u003e$KCl$\u003c\/span\u003e\u003cspan\u003e) storage buffer to keep the glass membrane and junction hydrated prior to installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eMeasurement Range:\u003c\/b\u003e\u003cspan\u003e 0.\u003c\/span\u003e\u003cspan\u003e00 to 14.\u003c\/span\u003e\u003cspan\u003e00 pH.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eCalibration Compatibility:\u003c\/b\u003e\u003cspan\u003e Compatible with standard 2-point buffer calibrations (pH 7.\u003c\/span\u003e\u003cspan\u003e00 zero reference,\u003c\/span\u003e\u003cspan\u003e pH 4.\u003c\/span\u003e\u003cspan\u003e00 or 10.\u003c\/span\u003e\u003cspan\u003e00 span slope).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eSlope Efficiency:\u003c\/b\u003e\u003cspan\u003e Typically \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"95\\%\" data-index-in-node=\"28\"\u003e$95\\%$\u003c\/span\u003e\u003cspan\u003e to \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"105\\%\" data-index-in-node=\"36\"\u003e$105\\%$\u003c\/span\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"54\" data-index-in-node=\"51\"\u003e$54$\u003c\/span\u003e\u003cspan\u003e to \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"59\\text{ mV}\" data-index-in-node=\"57\"\u003e$59\\text{ mV}$\u003c\/span\u003e\u003cspan\u003e per pH unit at 25°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eResponse Time:\u003c\/b\u003e\u003cspan\u003e Reaches \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"95\\%\" data-index-in-node=\"23\"\u003e$95\\%$\u003c\/span\u003e\u003cspan\u003e of final reading within \u003c\/span\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"52\"\u003e3 to 10 seconds\u003c\/b\u003e\u003cspan\u003e in active bypass flow.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eCable Length:\u003c\/b\u003e\u003cspan\u003e Standard \u003c\/span\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"23\"\u003e10-foot\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 3.\u003c\/span\u003e\u003cspan\u003e0 m) lead (optional 20-foot or 30-foot variants for remote panel mounts).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eOperating Temperature Range:\u003c\/b\u003e\u003cspan\u003e 32°F to 140°F (0°C to 60°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eMaximum Operating Pressure:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"28\"\u003e50 PSI\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 3.\u003c\/span\u003e\u003cspan\u003e45 bar) when seated in a compatible acrylic flow cell.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eProcess Connection:\u003c\/b\u003e\u003cspan\u003e 1\/2\" NPT or 3\/4\" NPT threaded body \/ compression collar gland mount (compatible with Pool Link 500 Series,\u003c\/span\u003e\u003cspan\u003e Legacy chambers,\u003c\/span\u003e\u003cspan\u003e and Hayward\/CAT flow manifolds).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eHandling \u0026amp; Storage Protocols\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eHydration Requirement:\u003c\/b\u003e\u003cspan\u003e Never allow the probe tip to dry out.\u003c\/span\u003e\u003cspan\u003e If stored out of the flow stream,\u003c\/span\u003e\u003cspan\u003e always reseal inside the storage boot filled with 4.\u003c\/span\u003e\u003cspan\u003e0 M KCl buffer (or pH 7.\u003c\/span\u003e\u003cspan\u003e00 buffer in emergencies).\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"198\"\u003eNever store in deionized or distilled water\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e which leaches the reference electrolyte.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eCleaning Procedure:\u003c\/b\u003e\u003cspan\u003e Mineral scaling or calcium deposits should be removed by soaking the tip in a dilute acid solution (5% to 10% hydrochloric acid or standard household vinegar) for 5 to 10 minutes,\u003c\/span\u003e\u003cspan\u003e followed by a thorough rinse with clean tap water.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":67968767885423,"sku":"PROBE-PH-BNC","price":627.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/gain-express-e-2627-e-2627-ph-probe-with-bnc-connector-150cm-long-cable-0-14ph-test-sensor-electrode-for-ph-meter-monitor-controller-replacement-kit-for.webp?v=1792680306","url":"https:\/\/commercialpoolandspasupplies.com\/products\/link-automation-ph-probe-with-bnc-connector-cable","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}