{"product_id":"link-automation-ph-probe-with-conx-connector-cable","title":"LINK AUTOMATION, pH PROBE WITH CONX CONNECTOR CABLE","description":"\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003eLink Automation pH Probe with CONX Connector Cable\u003c\/b\u003e\u003cspan\u003e (Pool Link \/ Link Automation) is a heavy-duty,\u003c\/span\u003e\u003cspan\u003e commercial-grade combination electrode engineered for automated commercial pool,\u003c\/span\u003e\u003cspan class=\"\"\u003e spa,\u003c\/span\u003e\u003cspan\u003e and aquatic chemistry controllers requiring a sealed,\u003c\/span\u003e\u003cspan\u003e quick-disconnect circular connector.\u003c\/span\u003e\u003cspan\u003e Designed to replace conventional twist-on BNC plugs in high-humidity or corrosive equipment rooms,\u003c\/span\u003e\u003cspan\u003e the \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"382\" class=\"\"\u003eCONX\u003c\/b\u003e\u003cspan\u003e (circular sealed industrial connector) variant provides an IP67\/NEMA 6P rated,\u003c\/span\u003e\u003cspan\u003e water-tight physical seal directly at the controller enclosure bulkhead or in-line cable junction,\u003c\/span\u003e\u003cspan\u003e completely preventing moisture-induced signal degradation and pin oxidation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"1\"\u003eHardware \u0026amp; Analytical Architecture\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cspan\u003eEngineered to maintain precision millivolt signal fidelity in aggressive commercial pump room atmospheres:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eCONX Sealed Pin Interface:\u003c\/b\u003e\u003cspan class=\"\"\u003e Terminated with a molded,\u003c\/span\u003e\u003cspan class=\"\"\u003e multi-pin,\u003c\/span\u003e\u003cspan class=\"\"\u003e circular locking industrial connector featuring internal silicone\/nitrile O-rings and a threaded or bayonet locking collar.\u003c\/span\u003e\u003cspan\u003e This configuration prevents acid vapor,\u003c\/span\u003e\u003cspan\u003e chloramine gas,\u003c\/span\u003e\u003cspan\u003e and washdown spray from contacting the pins,\u003c\/span\u003e\u003cspan\u003e eliminating high-resistance contact faults common to exposed BNC junctions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eCombination Sensing Element:\u003c\/b\u003e\u003cspan\u003e Houses both the glass measuring electrode and the reference half-cell in a single,\u003c\/span\u003e\u003cspan\u003e high-durability polymer or glass housing.\u003c\/span\u003e\u003cspan\u003e The reference chamber utilizes a gelled silver\/silver chloride (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"Ag\/AgCl\" data-index-in-node=\"218\"\u003e$Ag\/AgCl$\u003c\/span\u003e\u003cspan\u003e) electrolyte system that requires no ongoing replenishment or pressurization.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003ePorous Liquid Junction:\u003c\/b\u003e\u003cspan\u003e Features a porous Teflon or ceramic annular junction designed to resist fouling from suspended bather oils,\u003c\/span\u003e\u003cspan\u003e organic films,\u003c\/span\u003e\u003cspan\u003e and calcium carbonate scaling while maintaining low electrical junction resistance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eDouble-Shielded Coaxial Lead:\u003c\/b\u003e\u003cspan\u003e Heavy-gauge,\u003c\/span\u003e\u003cspan\u003e low-noise shielded coaxial cable designed to suppress electromagnetic interference (EMI) and radio frequency interference (RFI) induced by variable-frequency drives (VFDs),\u003c\/span\u003e\u003cspan\u003e commercial pump motors,\u003c\/span\u003e\u003cspan\u003e and chemical feed solenoids.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003ePre-Hydrated Wetting Cap:\u003c\/b\u003e\u003cspan\u003e Ships fitted with a liquid-tight storage boot filled with 3.\u003c\/span\u003e\u003cspan\u003e8 M or 4.\u003c\/span\u003e\u003cspan\u003e0 M potassium chloride (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"KCl\" data-index-in-node=\"119\"\u003e$KCl$\u003c\/span\u003e\u003cspan\u003e) reference storage buffer to preserve the glass hydration layer and reference junction during transit and storage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eMeasurement Range:\u003c\/b\u003e\u003cspan\u003e 0.\u003c\/span\u003e\u003cspan\u003e00 to 14.\u003c\/span\u003e\u003cspan\u003e00 pH.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eCalibration Compatibility:\u003c\/b\u003e\u003cspan\u003e Compatible with standard 2-point buffer calibrations (pH 7.\u003c\/span\u003e\u003cspan\u003e00 zero potential,\u003c\/span\u003e\u003cspan\u003e pH 4.\u003c\/span\u003e\u003cspan\u003e00 or 10.\u003c\/span\u003e\u003cspan\u003e00 span slope).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eNernstian Slope Efficiency:\u003c\/b\u003e\u003cspan\u003e Typically \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"95\\%\" data-index-in-node=\"38\"\u003e$95\\%$\u003c\/span\u003e\u003cspan\u003e to \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"105\\%\" data-index-in-node=\"46\"\u003e$105\\%$\u003c\/span\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"54\" data-index-in-node=\"61\"\u003e$54$\u003c\/span\u003e\u003cspan\u003e to \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"59\\text{ mV}\" data-index-in-node=\"67\"\u003e$59\\text{ mV}$\u003c\/span\u003e\u003cspan\u003e per pH unit at 25°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eResponse Time:\u003c\/b\u003e\u003cspan\u003e Reaches \u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"95\\%\" data-index-in-node=\"23\"\u003e$95\\%$\u003c\/span\u003e\u003cspan\u003e of final stable reading within \u003c\/span\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"59\"\u003e3 to 10 seconds\u003c\/b\u003e\u003cspan\u003e in active bypass flow.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eConnector Type:\u003c\/b\u003e\u003cspan\u003e Molded CONX circular multi-pin connector (water-tight quick-disconnect locking collar).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eCable Length:\u003c\/b\u003e\u003cspan\u003e Standard \u003c\/span\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"23\"\u003e10-foot\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 3.\u003c\/span\u003e\u003cspan\u003e0 m) lead (optional 20-foot or 30-foot extended runs available for remote enclosure routing).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eOperating Temperature Range:\u003c\/b\u003e\u003cspan\u003e 32°F to 140°F (0°C to 60°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eMaximum Operating Pressure:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"28\"\u003e50 PSI\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 3.\u003c\/span\u003e\u003cspan\u003e45 bar) in commercial flow cell manifolds.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,8,0\"\u003e\u003cb data-path-to-node=\"6,8,0\" data-index-in-node=\"0\"\u003eProcess Mounting Fitting:\u003c\/b\u003e\u003cspan\u003e Standard 1\/2\" NPT or 3\/4\" NPT threaded body \/ compression gland mount (compatible with Pool Link 500 Series,\u003c\/span\u003e\u003cspan\u003e Legacy chambers,\u003c\/span\u003e\u003cspan\u003e and standard commercial flow manifolds).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"8\"\u003eHandling \u0026amp; Storage Protocols\u003c\/h3\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eHydration Requirement:\u003c\/b\u003e\u003cspan\u003e The sensor tip must remain continuously hydrated.\u003c\/span\u003e\u003cspan\u003e When removed from the sample flow cell,\u003c\/span\u003e\u003cspan\u003e always seal the probe inside the storage boot filled with 4.\u003c\/span\u003e\u003cspan\u003e0 M KCl buffer (or pH 7.\u003c\/span\u003e\u003cspan\u003e00 buffer in a temporary pinch).\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"230\"\u003eNever store the probe in distilled or deionized water\u003c\/b\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e as pure water rapidly leaches the reference ions through the porous liquid junction.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eCleaning Procedure:\u003c\/b\u003e\u003cspan\u003e Mineral scaling or calcium deposits should be removed by soaking the glass bulb in a dilute acid solution (5% to 10% hydrochloric acid or household white vinegar) for 5 to 10 minutes,\u003c\/span\u003e\u003cspan\u003e followed by a thorough rinse with clean tap water before recalibration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":67968860356719,"sku":"PROBE-PH-CONX","price":735.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/gain-express-e-2627-e-2627-ph-probe-with-bnc-connector-150cm-long-cable-0-14ph-test-sensor-electrode-for-ph-meter-monitor-controller-replacement-kit-for.webp?v=1792680306","url":"https:\/\/commercialpoolandspasupplies.com\/products\/link-automation-ph-probe-with-conx-connector-cable","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}