{"product_id":"pool-link-500-series-probe-chamber-3-probe","title":"Pool Link 500 Series Probe Chamber - 3 Probe","description":"\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003ePool Link 500 Series Probe Chamber - 3 Probe\u003c\/b\u003e\u003cspan\u003e is a heavy-duty,\u003c\/span\u003e\u003cspan\u003e commercial bypass flow cell manifold engineered to house three analytical electrodes simultaneously.\u003c\/span\u003e\u003cspan\u003e Plumbed into an auxiliary bypass line across the primary recirculation system,\u003c\/span\u003e\u003cspan\u003e it provides a stable,\u003c\/span\u003e\u003cspan\u003e low-turbulence sampling environment for three distinct sensors—most commonly a combination pH electrode,\u003c\/span\u003e\u003cspan\u003e a platinum-band ORP sensor,\u003c\/span\u003e\u003cspan\u003e and an electronic temperature probe (or Free Available Chlorine probe)—safeguarding sensor tips while ensuring rapid,\u003c\/span\u003e\u003cspan\u003e accurate water quality measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"1\"\u003eSystem Overview \u0026amp; Hardware Architecture\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cspan\u003eEngineered for municipal natatoriums,\u003c\/span\u003e\u003cspan\u003e waterparks,\u003c\/span\u003e\u003cspan\u003e institutional competition pools,\u003c\/span\u003e\u003cspan\u003e and resort spas requiring a dedicated three-sensor sampling hub:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eClear Machined Acrylic Solid-Block Body:\u003c\/b\u003e\u003cspan\u003e Precision-machined from a monolithic block of clear cast acrylic.\u003c\/span\u003e\u003cspan\u003e The transparent design permits immediate visual inspection of internal flow conditions,\u003c\/span\u003e\u003cspan\u003e air bubble accumulation,\u003c\/span\u003e\u003cspan\u003e and probe membrane fouling without taking the system off-line.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eThree-Port Inline Layout:\u003c\/b\u003e\u003cspan\u003e Accommodates three full-sized commercial electrodes in a linear hydraulic flow path designed to minimize dead zones and prevent chemical cross-interference or stagnation around sensor junctions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eInlet Flow Metering Needle Valve:\u003c\/b\u003e\u003cspan\u003e Chemical-resistant,\u003c\/span\u003e\u003cspan\u003e fine-threaded needle valve mounted directly on the bypass inlet to regulate sample water velocity,\u003c\/span\u003e\u003cspan\u003e preventing cavitation and excessive dynamic pressure against fragile glass sensor membranes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eManual Sample Draw Petcock:\u003c\/b\u003e\u003cspan\u003e Integrated low-pressure petcock located adjacent to the electrode sensing tips,\u003c\/span\u003e\u003cspan\u003e allowing operators to draw representative pool water for manual photometer,\u003c\/span\u003e\u003cspan\u003e DPD colorimeter,\u003c\/span\u003e\u003cspan\u003e or titrimetric calibration testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eRigid Panel Mounting Configuration:\u003c\/b\u003e\u003cspan\u003e Features rear mounting holes and flat mounting bosses for direct installation onto an equipment room backboard,\u003c\/span\u003e\u003cspan\u003e strut channel,\u003c\/span\u003e\u003cspan\u003e or wall panel.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003ePort Configuration:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"6,0,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,1,0,0\"\u003e\u003cspan\u003eThree 1\/2\" NPT or 3\/4\" NPT threaded\/compression gland ports compatible with standard commercial glass pH,\u003c\/span\u003e\u003cspan\u003e platinum-band ORP,\u003c\/span\u003e\u003cspan\u003e and solid-state temperature or amperometric probes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,1,1,0\"\u003e\u003cspan\u003eCaptive compression collars with Viton or EPDM O-ring compression seals to secure probes under positive pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eHydraulic Limits \u0026amp; Operating Parameters:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"6,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,1,0,0\"\u003e\u003cb data-path-to-node=\"6,1,1,0,0\" data-index-in-node=\"0\"\u003eMaximum Working Pressure:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"6,1,1,0,0\" data-index-in-node=\"26\"\u003e50 PSI\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 3.\u003c\/span\u003e\u003cspan\u003e45 bar).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,1,1,0\"\u003e\u003cb data-path-to-node=\"6,1,1,1,0\" data-index-in-node=\"0\"\u003eOptimal Bypass Flow Rate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"6,1,1,1,0\" data-index-in-node=\"26\"\u003e0.5 to 1.5 GPM\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 1.\u003c\/span\u003e\u003cspan\u003e9 to 5.\u003c\/span\u003e\u003cspan\u003e7 LPM).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,1,2,0\"\u003e\u003cb data-path-to-node=\"6,1,1,2,0\" data-index-in-node=\"0\"\u003eOperating Water Temperature:\u003c\/b\u003e\u003cspan\u003e 32°F to 120°F (0°C to 49°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003ePlumbing Connections:\u003c\/b\u003e\u003cspan\u003e Standard 1\/4\" NPT female inlet and outlet ports,\u003c\/span\u003e\u003cspan\u003e typically pre-fitted with 3\/8\" OD compression fittings for flexible polyethylene bypass tubing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":67968613417071,"sku":"LINKFLOW3","price":3311.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/AC075-min_800x_cc984834-3579-41ef-937b-600429fe98ea.webp?v=1792679781","url":"https:\/\/commercialpoolandspasupplies.com\/products\/pool-link-500-series-probe-chamber-3-probe","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}