{"product_id":"pool-link-500-series-probe-chamber-4-probe","title":"Pool Link 500 Series Probe Chamber - 4 Probe","description":"\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"0\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003ePool Link 500 Series Probe Chamber - 4 Probe\u003c\/b\u003e\u003cspan\u003e is an expanded,\u003c\/span\u003e\u003cspan\u003e commercial-grade bypass flow cell manifold engineered to house four analytical sensors simultaneously.\u003c\/span\u003e\u003cspan\u003e Plumbed into an auxiliary bypass line across the main pool recirculation loop,\u003c\/span\u003e\u003cspan\u003e it provides a stable,\u003c\/span\u003e\u003cspan\u003e low-turbulence sampling environment for complex commercial aquatic systems—typically accommodating combination pH,\u003c\/span\u003e\u003cspan\u003e platinum-band ORP,\u003c\/span\u003e\u003cspan\u003e temperature,\u003c\/span\u003e\u003cspan\u003e and either an amperometric Free Available Chlorine (FAC) or nephelometric turbidity sensor in a single,\u003c\/span\u003e\u003cspan\u003e compact acrylic block.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"1\"\u003eSystem Overview \u0026amp; Hardware Architecture\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cspan\u003eDesigned for high-bather-load commercial facilities,\u003c\/span\u003e\u003cspan\u003e competition aquatic centers,\u003c\/span\u003e\u003cspan\u003e and municipal water venues requiring comprehensive water chemistry and clarity monitoring:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eClear Machined Acrylic Solid-Block Body:\u003c\/b\u003e\u003cspan\u003e Precision-machined from a single block of heavy cast acrylic.\u003c\/span\u003e\u003cspan\u003e The optical-grade clarity permits direct visual inspection of internal flow conditions,\u003c\/span\u003e\u003cspan\u003e air bubble entrapment,\u003c\/span\u003e\u003cspan\u003e and probe membrane fouling across all four sensing wells without system depressurization.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eFour-Port In-Line Chamber Design:\u003c\/b\u003e\u003cspan\u003e Positions four analytical probes in a continuous hydraulic sequence optimized to deliver equal sample exchange rates while isolating sensor junctions to prevent chemical cross-contamination or electrical signal cross-talk.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eInlet Flow-Regulating Needle Valve:\u003c\/b\u003e\u003cspan\u003e Fine-threaded,\u003c\/span\u003e\u003cspan\u003e chemical-resistant metering valve located at the sample intake to throttle line pressure and maintain stable,\u003c\/span\u003e\u003cspan\u003e laminar flow across fragile sensing tips,\u003c\/span\u003e\u003cspan\u003e preventing cavitation and velocity impingement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eManual Calibration Petcock:\u003c\/b\u003e\u003cspan\u003e Integrated low-pressure sample valve positioned adjacent to the probe chambers,\u003c\/span\u003e\u003cspan\u003e allowing operators to draw representative pool water for routine photometer,\u003c\/span\u003e\u003cspan\u003e DPD colorimetric,\u003c\/span\u003e\u003cspan\u003e or titrimetric verification tests.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eRigid Backboard Mounting:\u003c\/b\u003e\u003cspan\u003e Rear drilled and tapped mounting holes facilitate direct attachment to an equipment backboard,\u003c\/span\u003e\u003cspan\u003e Unistrut channel,\u003c\/span\u003e\u003cspan\u003e or equipment room wall.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003ePort Configuration:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"6,0,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,1,0,0\"\u003e\u003cspan\u003eFour 1\/2\" NPT or 3\/4\" NPT threaded or compression gland ports compatible with commercial glass pH,\u003c\/span\u003e\u003cspan\u003e platinum ORP,\u003c\/span\u003e\u003cspan\u003e solid-state temperature,\u003c\/span\u003e\u003cspan\u003e and amperometric\/turbidity probe bodies.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,1,1,0\"\u003e\u003cspan\u003eCaptive compression collars with chemical-resistant Viton or EPDM O-rings for pressure-tight sealing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eHydraulic Operating Limits:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"6,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,1,0,0\"\u003e\u003cb data-path-to-node=\"6,1,1,0,0\" data-index-in-node=\"0\"\u003eMaximum Working Pressure:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"6,1,1,0,0\" data-index-in-node=\"26\"\u003e50 PSI\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 3.\u003c\/span\u003e\u003cspan\u003e45 bar).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,1,1,0\"\u003e\u003cb data-path-to-node=\"6,1,1,1,0\" data-index-in-node=\"0\"\u003eOptimal Bypass Flow Rate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"6,1,1,1,0\" data-index-in-node=\"26\"\u003e0.5 to 1.5 GPM\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 1.\u003c\/span\u003e\u003cspan\u003e9 to 5.\u003c\/span\u003e\u003cspan\u003e7 LPM).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,1,2,0\"\u003e\u003cb data-path-to-node=\"6,1,1,2,0\" data-index-in-node=\"0\"\u003eOperating Water Temperature:\u003c\/b\u003e\u003cspan\u003e 32°F to 120°F (0°C to 49°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003ePlumbing Connections:\u003c\/b\u003e\u003cspan\u003e Standard 1\/4\" NPT female inlet and outlet ports,\u003c\/span\u003e\u003cspan\u003e pre-fitted with 3\/8\" OD compression adapters for semi-rigid polyethylene sample tubing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eHydraulic Limits \u0026amp; Operating Parameters:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"6,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,1,0,0\"\u003e\u003cb data-path-to-node=\"6,1,1,0,0\" data-index-in-node=\"0\"\u003eMaximum Working Pressure:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"6,1,1,0,0\" data-index-in-node=\"26\"\u003e50 PSI\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 3.\u003c\/span\u003e\u003cspan\u003e45 bar).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,1,1,0\"\u003e\u003cb data-path-to-node=\"6,1,1,1,0\" data-index-in-node=\"0\"\u003eOptimal Bypass Flow Rate:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"6,1,1,1,0\" data-index-in-node=\"26\"\u003e0.5 to 1.5 GPM\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 1.\u003c\/span\u003e\u003cspan\u003e9 to 5.\u003c\/span\u003e\u003cspan\u003e7 LPM).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,1,2,0\"\u003e\u003cb data-path-to-node=\"6,1,1,2,0\" data-index-in-node=\"0\"\u003eOperating Water Temperature:\u003c\/b\u003e\u003cspan\u003e 32°F to 120°F (0°C to 49°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003ePlumbing Connections:\u003c\/b\u003e\u003cspan\u003e Standard 1\/4\" NPT female inlet and outlet ports,\u003c\/span\u003e\u003cspan\u003e typically pre-fitted with 3\/8\" OD compression fittings for flexible polyethylene bypass tubing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":67968618070127,"sku":"LINKFLOW4","price":3967.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/AC075-min_800x_cc984834-3579-41ef-937b-600429fe98ea.webp?v=1792679781","url":"https:\/\/commercialpoolandspasupplies.com\/products\/pool-link-500-series-probe-chamber-4-probe","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}