{"product_id":"pool-link-500-series-tac-probe-membrane-cap","title":"Pool Link 500 Series, TAC Probe Membrane Cap","description":"\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\" class=\"\"\u003ePool Link 500 Series TAC Probe Membrane Cap\u003c\/b\u003e\u003cspan class=\"\"\u003e (Pool Link \/ Link Automation) is the consumable front-end sensing element for the 500 Series Amperometric Total Available Chlorine (0–20 PPM) probe.\u003c\/span\u003e\u003cspan class=\"\"\u003e Screwed directly onto the lower barrel of the electrode shaft,\u003c\/span\u003e\u003cspan class=\"\"\u003e the membrane cap retains the specialized potassium iodide\/buffer electrolyte and acts as the semi-permeable diffusion barrier separating the active pool water flow from the internal precious metal electrode assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eHardware Architecture \u0026amp; Material Composition\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan\u003eDesigned to facilitate multi-species chlorine diffusion while protecting internal electronics from harsh commercial water conditions:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eCatalytic Diffusion Membrane:\u003c\/b\u003e\u003cspan\u003e Outfitted with an ultra-thin,\u003c\/span\u003e\u003cspan\u003e microporous hydrophilic\/polymeric membrane (typically treated PTFE or PVDF).\u003c\/span\u003e\u003cspan\u003e Unlike direct FAC membranes,\u003c\/span\u003e\u003cspan\u003e this matrix allows both free chlorine (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"\\text{HOCl}\/\\text{OCl}^-\" data-index-in-node=\"205\"\u003e$\\text{HOCl}\/\\text{OCl}^-$\u003c\/span\u003e\u003cspan\u003e) and combined chloramine species (monochloramine,\u003c\/span\u003e\u003cspan\u003e dichloramine,\u003c\/span\u003e\u003cspan\u003e and organic chloramines) to diffuse inward to react with the internal electrolyte.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eChemical-Grade Polymer Housing:\u003c\/b\u003e\u003cspan\u003e Precision-machined or molded from PVDF (polyvinylidene fluoride) or chemical-resistant polyacetal (Delrin) to withstand continuous exposure to high total chlorine residuals,\u003c\/span\u003e\u003cspan\u003e ozone off-gassing,\u003c\/span\u003e\u003cspan\u003e cyanuric acid,\u003c\/span\u003e\u003cspan\u003e and periodic acid washes without embrittlement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eInternal Electrolyte Reservoir:\u003c\/b\u003e\u003cspan\u003e Calibrated internal volume engineered to hold 1.\u003c\/span\u003e\u003cspan\u003e5 mL to 3.\u003c\/span\u003e\u003cspan\u003e0 mL of TAC electrolyte gel,\u003c\/span\u003e\u003cspan\u003e maintaining steady ionic contact between the noble metal cathode (platinum or gold) and the silver\/silver chloride (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"\\text{Ag\/AgCl}\" data-index-in-node=\"235\"\u003e$\\text{Ag\/AgCl}$\u003c\/span\u003e\u003cspan\u003e) reference anode.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eHydrostatic Pressure Venting:\u003c\/b\u003e\u003cspan\u003e Features internal relief micro-grooves along the upper thread shoulder that vent displaced electrolyte and air during assembly,\u003c\/span\u003e\u003cspan\u003e preventing hydrostatic over-pressurization from stretching or puncturing the delicate membrane face.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\"\u003eDual Elastomeric Seal:\u003c\/b\u003e\u003cspan\u003e Incorporates an internal Viton (FKM) or EPDM O-ring to prevent sample pool water from entering the electrolyte chamber and prevent reagent leakage into the analytical bypass manifold.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eCompatible Sensor:\u003c\/b\u003e\u003cspan\u003e Pool Link 500 Series Amperometric Total Available Chlorine (TAC) Probe (0–20 PPM).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eOperating pH Range:\u003c\/b\u003e\u003cspan\u003e 6.\u003c\/span\u003e\u003cspan\u003e50 to 8.\u003c\/span\u003e\u003cspan\u003e50 pH (optimized for commercial natatorium chloramine tracking).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eMaximum Working Pressure:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"26\"\u003e50 PSI\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 3.\u003c\/span\u003e\u003cspan\u003e45 bar) within bypass flow cells.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eOperating Water Temperature:\u003c\/b\u003e\u003cspan\u003e 35°F to 120°F (2°C to 49°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eService Life \/ Replacement Interval:\u003c\/b\u003e\u003cspan\u003e Typically \u003c\/span\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"47\"\u003e3 to 6 months\u003c\/b\u003e\u003cspan\u003e under continuous commercial operation (depletion occurs faster than FAC caps due to ongoing chemical interaction with chloramines and iodide consumption).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003ePackaging \u0026amp; Storage:\u003c\/b\u003e\u003cspan class=\"\"\u003e Shipped dry in a sealed rigid blister pack or protective carton with internal wetting\/cushioning boots.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\" class=\"\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003cdiv class=\"attachment-container unknown md-has-block-component\"\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003csequence class=\"lm-enabled ng-star-inserted\"\u003e\u003cdiv role=\"list\" class=\"sequence-container\" jslog=\"308913;track:impression,attention\" data-hveid=\"0\" decode-data-ved=\"1\" data-ved=\"0CAAQse0SahgKEwjHxM7M582XAxUAAAAAHQAAAAAQpQc\"\u003e\n\u003cdiv role=\"listitem\" class=\"sequence-event ng-star-inserted\"\u003e\u003cdiv class=\"sequence-event-content\"\u003e\u003cdiv class=\"sequence-event-description gds-body-l\"\u003e\n\u003cspan only-show-to-message-actions=\"\" data-test-id=\"sequence-export-header\" class=\"only-show-to-message-actions\"\u003e\u003cstrong\u003e\u003c!----\u003e\u003c!----\u003e1.\u003c!----\u003e\u003c!----\u003eIsolate Bypass Flow and Extract Probe:\u003c!----\u003e\u003c\/strong\u003ePrerequisite.\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e\u003cstructured-node-sequence _nghost-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003cstructured-text _ngcontent-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003c!----\u003e\u003c!----\u003e\u003cp class=\"ng-star-inserted\"\u003eClose the inlet and outlet isolation valves on the 500 Series acrylic flow cell to relieve line pressure. Loosen the compression gland nut and slide the TAC probe out of the manifold port.\u003c\/p\u003e\n\u003cp class=\"ng-star-inserted\"\u003e\u003ci\u003eVerification:\u003c\/i\u003e Flow cell pressure gauge drops to 0 PSI and no water weeps from the open probe port.\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c\/structured-text\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/structured-node-sequence\u003e\u003c!----\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv role=\"listitem\" class=\"sequence-event ng-star-inserted\"\u003e\u003cdiv class=\"sequence-event-content\"\u003e\u003cdiv class=\"sequence-event-description gds-body-l\"\u003e\n\u003cspan only-show-to-message-actions=\"\" data-test-id=\"sequence-export-header\" class=\"only-show-to-message-actions\"\u003e\u003cstrong\u003e\u003c!----\u003e\u003c!----\u003e2.\u003c!----\u003e\u003c!----\u003eRemove Depleted Cap and Clean Cathode:\u003c!----\u003e\u003c\/strong\u003e3 min.\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e\u003cstructured-node-sequence _nghost-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003cstructured-text _ngcontent-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003c!----\u003e\u003c!----\u003e\u003cp class=\"ng-star-inserted\"\u003eUnscrew the old membrane cap counter-clockwise over a waste receptacle and discard the spent electrolyte. Rinse the internal cathode tip with distilled water and gently wipe it with a soft lint-free cloth or lens paper.\u003c\/p\u003e\n\u003cp class=\"ng-star-inserted\"\u003e\u003ci\u003eVerification:\u003c\/i\u003e The noble metal cathode surface is bright and free of yellowed iodide staining or mineral deposits.\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c\/structured-text\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/structured-node-sequence\u003e\u003c!----\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv role=\"listitem\" class=\"sequence-event ng-star-inserted\"\u003e\u003cdiv class=\"sequence-event-content\"\u003e\u003cdiv class=\"sequence-event-description gds-body-l\"\u003e\n\u003cspan only-show-to-message-actions=\"\" data-test-id=\"sequence-export-header\" class=\"only-show-to-message-actions\"\u003e\u003cstrong\u003e\u003c!----\u003e\u003c!----\u003e3.\u003c!----\u003e\u003c!----\u003eFill and Seat the Replacement Cap:\u003c!----\u003e\u003c\/strong\u003e5 min.\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e\u003cstructured-node-sequence _nghost-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003cstructured-text _ngcontent-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003c!----\u003e\u003c!----\u003e\u003cp class=\"ng-star-inserted\"\u003eFill the new replacement membrane cap approximately 3\/4 full with fresh, bubble-free TAC probe electrolyte gel. With the probe held vertically, slide the cap onto the shaft and thread it on slowly to allow excess gel to vent through the relief threads.\u003c\/p\u003e\n\u003cp class=\"ng-star-inserted\"\u003e\u003ci\u003eVerification:\u003c\/i\u003e The cap seats flush against the O-ring shoulder, and the membrane face remains flat without trapped air bubbles.\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c\/structured-text\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/structured-node-sequence\u003e\u003c!----\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv role=\"listitem\" class=\"sequence-event ng-star-inserted\"\u003e\u003cdiv class=\"sequence-event-content\"\u003e\u003cdiv class=\"sequence-event-description gds-body-l\"\u003e\n\u003cspan only-show-to-message-actions=\"\" data-test-id=\"sequence-export-header\" class=\"only-show-to-message-actions\"\u003e\u003cstrong\u003e\u003c!----\u003e\u003c!----\u003e4.\u003c!----\u003e\u003c!----\u003eReinstall in Flow Cell and Polarize:\u003c!----\u003e\u003c\/strong\u003e2–4 hours.\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e\u003cstructured-node-sequence _nghost-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003cstructured-text _ngcontent-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003c!----\u003e\u003c!----\u003e\u003cp class=\"ng-star-inserted\"\u003eReinstall the probe in the acrylic manifold, tighten the compression nut, and reopen the bypass valves to restore 0.5 to 1.5 GPM flow. Allow the sensor to polarize electrically under power for 2 to 4 hours before calibrating against a DPD-3\/4 photometer test.\u003c\/p\u003e\n\u003cp class=\"ng-star-inserted\"\u003e\u003ci\u003eVerification:\u003c\/i\u003e The TAC PPM readout on the Pool Link 501 controller settles into a stable, non-drifting baseline.\u003c\/p\u003e\u003c\/structured-text\u003e\u003c\/structured-node-sequence\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/sequence\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"attachment-container unknown md-has-block-component\"\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003csequence class=\"lm-enabled ng-star-inserted\"\u003e\u003cdiv role=\"list\" class=\"sequence-container\" jslog=\"308913;track:impression,attention\" data-hveid=\"0\" decode-data-ved=\"1\" data-ved=\"0CAAQse0SahgKEwjHxM7M582XAxUAAAAAHQAAAAAQpQc\"\u003e\n\u003cdiv role=\"listitem\" class=\"sequence-event ng-star-inserted\"\u003e\u003cdiv class=\"sequence-event-content\"\u003e\u003cdiv class=\"sequence-event-description gds-body-l\"\u003e\n\u003cspan only-show-to-message-actions=\"\" data-test-id=\"sequence-export-header\" class=\"only-show-to-message-actions\"\u003e\u003cstrong\u003e\u003c!----\u003e\u003c!----\u003e1.\u003c!----\u003e\u003c!----\u003eIsolate Bypass Flow and Extract Probe:\u003c!----\u003e\u003c\/strong\u003ePrerequisite.\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e\u003cstructured-node-sequence _nghost-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003cstructured-text _ngcontent-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003c!----\u003e\u003c!----\u003e\u003cp class=\"ng-star-inserted\"\u003eClose the inlet and outlet isolation valves on the 500 Series acrylic flow cell to relieve line pressure. Loosen the compression gland nut and slide the TAC probe out of the manifold port.\u003c\/p\u003e\n\u003cp class=\"ng-star-inserted\"\u003e\u003ci\u003eVerification:\u003c\/i\u003e Flow cell pressure gauge drops to 0 PSI and no water weeps from the open probe port.\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c\/structured-text\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/structured-node-sequence\u003e\u003c!----\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv role=\"listitem\" class=\"sequence-event ng-star-inserted\"\u003e\u003cdiv class=\"sequence-event-content\"\u003e\u003cdiv class=\"sequence-event-description gds-body-l\"\u003e\n\u003cspan only-show-to-message-actions=\"\" data-test-id=\"sequence-export-header\" class=\"only-show-to-message-actions\"\u003e\u003cstrong\u003e\u003c!----\u003e\u003c!----\u003e2.\u003c!----\u003e\u003c!----\u003eRemove Depleted Cap and Clean Cathode:\u003c!----\u003e\u003c\/strong\u003e3 min.\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e\u003cstructured-node-sequence _nghost-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003cstructured-text _ngcontent-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003c!----\u003e\u003c!----\u003e\u003cp class=\"ng-star-inserted\"\u003eUnscrew the old membrane cap counter-clockwise over a waste receptacle and discard the spent electrolyte. Rinse the internal cathode tip with distilled water and gently wipe it with a soft lint-free cloth or lens paper.\u003c\/p\u003e\n\u003cp class=\"ng-star-inserted\"\u003e\u003ci\u003eVerification:\u003c\/i\u003e The noble metal cathode surface is bright and free of yellowed iodide staining or mineral deposits.\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c\/structured-text\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/structured-node-sequence\u003e\u003c!----\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv role=\"listitem\" class=\"sequence-event ng-star-inserted\"\u003e\u003cdiv class=\"sequence-event-content\"\u003e\u003cdiv class=\"sequence-event-description gds-body-l\"\u003e\n\u003cspan only-show-to-message-actions=\"\" data-test-id=\"sequence-export-header\" class=\"only-show-to-message-actions\"\u003e\u003cstrong\u003e\u003c!----\u003e\u003c!----\u003e3.\u003c!----\u003e\u003c!----\u003eFill and Seat the Replacement Cap:\u003c!----\u003e\u003c\/strong\u003e5 min.\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e\u003cstructured-node-sequence _nghost-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003cstructured-text _ngcontent-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003c!----\u003e\u003c!----\u003e\u003cp class=\"ng-star-inserted\"\u003eFill the new replacement membrane cap approximately 3\/4 full with fresh, bubble-free TAC probe electrolyte gel. With the probe held vertically, slide the cap onto the shaft and thread it on slowly to allow excess gel to vent through the relief threads.\u003c\/p\u003e\n\u003cp class=\"ng-star-inserted\"\u003e\u003ci\u003eVerification:\u003c\/i\u003e The cap seats flush against the O-ring shoulder, and the membrane face remains flat without trapped air bubbles.\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c\/structured-text\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/structured-node-sequence\u003e\u003c!----\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv role=\"listitem\" class=\"sequence-event ng-star-inserted\"\u003e\u003cdiv class=\"sequence-event-content\"\u003e\u003cdiv class=\"sequence-event-description gds-body-l\"\u003e\n\u003cspan only-show-to-message-actions=\"\" data-test-id=\"sequence-export-header\" class=\"only-show-to-message-actions\"\u003e\u003cstrong\u003e\u003c!----\u003e\u003c!----\u003e4.\u003c!----\u003e\u003c!----\u003eReinstall in Flow Cell and Polarize:\u003c!----\u003e\u003c\/strong\u003e2–4 hours.\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e\u003cstructured-node-sequence _nghost-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003cstructured-text _ngcontent-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003c!----\u003e\u003c!----\u003e\u003cp class=\"ng-star-inserted\"\u003eReinstall the probe in the acrylic manifold, tighten the compression nut, and reopen the bypass valves to restore 0.5 to 1.5 GPM flow. Allow the sensor to polarize electrically under power for 2 to 4 hours before calibrating against a DPD-3\/4 photometer test.\u003c\/p\u003e\n\u003cp class=\"ng-star-inserted\"\u003e\u003ci\u003eVerification:\u003c\/i\u003e The TAC PPM readout on the Pool Link 501 controller settles into a stable, non-drifting baseline.\u003c\/p\u003e\u003c\/structured-text\u003e\u003c\/structured-node-sequence\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/sequence\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"attachment-container unknown md-has-block-component\"\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003csequence class=\"lm-enabled ng-star-inserted\"\u003e\u003cdiv role=\"list\" class=\"sequence-container\" jslog=\"308913;track:impression,attention\" data-hveid=\"0\" decode-data-ved=\"1\" data-ved=\"0CAAQse0SahgKEwjHxM7M582XAxUAAAAAHQAAAAAQjwc\"\u003e\n\u003cdiv role=\"listitem\" class=\"sequence-event ng-star-inserted\"\u003e\u003cdiv class=\"sequence-event-content\"\u003e\u003cdiv class=\"sequence-event-description gds-body-l\"\u003e\n\u003cspan only-show-to-message-actions=\"\" data-test-id=\"sequence-export-header\" class=\"only-show-to-message-actions\"\u003e\u003cstrong\u003e\u003c!----\u003e\u003c!----\u003e1.\u003c!----\u003e\u003c!----\u003eIsolate Bypass Flow and Remove Probe:\u003c!----\u003e\u003c\/strong\u003ePrerequisite.\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e\u003cstructured-node-sequence _nghost-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003cstructured-text _ngcontent-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003c!----\u003e\u003c!----\u003e\u003cp class=\"ng-star-inserted\"\u003eClose the inlet and outlet isolation valves on the 500 Series acrylic flow cell to relieve hydraulic pressure. Unthread the probe's compression collar and extract the sensor body from the manifold.\u003c\/p\u003e\n\u003cp class=\"ng-star-inserted\"\u003e\u003ci\u003eVerification:\u003c\/i\u003e Flow cell pressure gauge drops to 0 PSI and no bypass water flows from the open port.\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c\/structured-text\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/structured-node-sequence\u003e\u003c!----\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv role=\"listitem\" class=\"sequence-event ng-star-inserted\"\u003e\u003cdiv class=\"sequence-event-content\"\u003e\u003cdiv class=\"sequence-event-description gds-body-l\"\u003e\n\u003cspan only-show-to-message-actions=\"\" data-test-id=\"sequence-export-header\" class=\"only-show-to-message-actions\"\u003e\u003cstrong\u003e\u003c!----\u003e\u003c!----\u003e2.\u003c!----\u003e\u003c!----\u003eFlush Depleted Electrolyte and Clean Electrode:\u003c!----\u003e\u003c\/strong\u003e2 min.\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e\u003cstructured-node-sequence _nghost-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003cstructured-text _ngcontent-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003c!----\u003e\u003c!----\u003e\u003cp class=\"ng-star-inserted\"\u003eUnscrew the lower membrane cap and discard old electrolyte into a sink or waste container. Rinse the internal cathode tip and cap reservoir thoroughly with distilled or deionized water, then gently blot dry with a lint-free tissue.\u003c\/p\u003e\n\u003cp class=\"ng-star-inserted\"\u003e\u003ci\u003eVerification:\u003c\/i\u003e The internal chamber is clean and the cathode surface is free of mineral buildup or discolored gel residue.\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c\/structured-text\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/structured-node-sequence\u003e\u003c!----\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv role=\"listitem\" class=\"sequence-event ng-star-inserted\"\u003e\u003cdiv class=\"sequence-event-content\"\u003e\u003cdiv class=\"sequence-event-description gds-body-l\"\u003e\n\u003cspan only-show-to-message-actions=\"\" data-test-id=\"sequence-export-header\" class=\"only-show-to-message-actions\"\u003e\u003cstrong\u003e\u003c!----\u003e\u003c!----\u003e3.\u003c!----\u003e\u003c!----\u003eFill Membrane Cap with Fresh Gel:\u003c!----\u003e\u003c\/strong\u003e3 min.\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e\u003cstructured-node-sequence _nghost-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003cstructured-text _ngcontent-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003c!----\u003e\u003c!----\u003e\u003cp class=\"ng-star-inserted\"\u003eInvert the FAC Probe Gel bottle and tap it gently to dislodge air bubbles from the dispensing nozzle. Carefully fill the membrane cap approximately \u003cb\u003e3\/4 full\u003c\/b\u003e with fresh gel, avoiding micro-bubble entrapment.\u003c\/p\u003e\n\u003cp class=\"ng-star-inserted\"\u003e\u003ci\u003eVerification:\u003c\/i\u003e The gel inside the cap is clear, continuous, and free of visible air pockets.\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c\/structured-text\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/structured-node-sequence\u003e\u003c!----\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv role=\"listitem\" class=\"sequence-event ng-star-inserted\"\u003e\u003cdiv class=\"sequence-event-content\"\u003e\u003cdiv class=\"sequence-event-description gds-body-l\"\u003e\n\u003cspan only-show-to-message-actions=\"\" data-test-id=\"sequence-export-header\" class=\"only-show-to-message-actions\"\u003e\u003cstrong\u003e\u003c!----\u003e\u003c!----\u003e4.\u003c!----\u003e\u003c!----\u003eThread Cap and Vent Hydrostatic Pressure:\u003c!----\u003e\u003c\/strong\u003e2 min.\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e\u003cstructured-node-sequence _nghost-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003cstructured-text _ngcontent-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003c!----\u003e\u003c!----\u003e\u003cp class=\"ng-star-inserted\"\u003eHolding the probe vertically, slowly screw the filled membrane cap onto the probe shaft. Allow excess gel to escape through the pressure-relief threads\/vent without forcing or stretching the delicate membrane face.\u003c\/p\u003e\n\u003cp class=\"ng-star-inserted\"\u003e\u003ci\u003eVerification:\u003c\/i\u003e The cap is firmly seated against its stop and the outer membrane remains smooth and flat.\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c\/structured-text\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/structured-node-sequence\u003e\u003c!----\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv role=\"listitem\" class=\"sequence-event ng-star-inserted\"\u003e\u003cdiv class=\"sequence-event-content\"\u003e\u003cdiv class=\"sequence-event-description gds-body-l\"\u003e\n\u003cspan only-show-to-message-actions=\"\" data-test-id=\"sequence-export-header\" class=\"only-show-to-message-actions\"\u003e\u003cstrong\u003e\u003c!----\u003e\u003c!----\u003e5.\u003c!----\u003e\u003c!----\u003eReinstall in Flow Cell and Polarize:\u003c!----\u003e\u003c\/strong\u003e1–2 hours.\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e\u003cstructured-node-sequence _nghost-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003cstructured-text _ngcontent-ng-c1241692568=\"\" class=\"ng-star-inserted\"\u003e\u003c!----\u003e\u003c!----\u003e\u003cp class=\"ng-star-inserted\"\u003eReinstall the probe in the acrylic flow cell, tighten the compression collar, and reopen the bypass valves. Restore steady water flow (0.5 to 1.5 GPM) and let the sensor polarize under power for 1 to 2 hours before running span calibration.\u003c\/p\u003e\n\u003cp class=\"ng-star-inserted\"\u003e\u003ci\u003eVerification:\u003c\/i\u003e The FAC reading on the Pool Link 501 controller settles into a stable, non-drifting baseline matching a DPD photometer test.\u003c\/p\u003e\u003c\/structured-text\u003e\u003c\/structured-node-sequence\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/sequence\u003e\n\u003c\/div\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":67968945356911,"sku":"LINK-TACCAP","price":799.0,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/mermade-filter-500-series-automatic-chemical-feed-controller-by-pool-link-474-474_d4279122-6b2c-41b3-b454-449be02908c2.jpg?v=1792681416","url":"https:\/\/commercialpoolandspasupplies.com\/products\/pool-link-500-series-tac-probe-membrane-cap","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}