{"product_id":"stenner-85mp5-pump-fx-25psi-85gpd-120v-60hz-3-8w","title":"STENNER 85MP5 PUMP FX 25PSI 85GPD 120V\/60HZ 3\/8W","description":"\u003cp data-path-to-node=\"0\" class=\"first-token\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\" class=\"\"\u003eStenner 85MFL5A3SUAA (85 Series Classic Fixed Rate)\u003c\/b\u003e\u003cspan\u003e is an industrial-grade,\u003c\/span\u003e\u003cspan\u003e peristaltic positive displacement chemical metering pump engineered for high-pressure injection in commercial aquatic automation,\u003c\/span\u003e\u003cspan\u003e water treatment,\u003c\/span\u003e\u003cspan\u003e and municipal chemical feed applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\"\u003e\u003cspan\u003eOperating on a fixed-rate duty cycle,\u003c\/span\u003e\u003cspan\u003e it delivers \u003c\/span\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"50\"\u003e40.0 GPD (Gallons Per Day)\u003c\/b\u003e\u003cspan\u003e against system head pressures up to \u003c\/span\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"113\"\u003e100 PSI (6.9 bar)\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003cspan\u003e In commercial aquatic mechanical rooms running Pool Link 500\/1000 Series controllers,\u003c\/span\u003e\u003cspan\u003e this model is typically selected when injecting chemicals (such as 12.\u003c\/span\u003e\u003cspan\u003e5% to 15% liquid sodium hypochlorite or 31.\u003c\/span\u003e\u003cspan\u003e45% muriatic acid) into deep pool recirculating mains,\u003c\/span\u003e\u003cspan\u003e multi-story risers,\u003c\/span\u003e\u003cspan\u003e or filtration loops where return pressures exceed the 25 PSI limit of the 45 Series.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eNomenclature \u0026amp; Smart-Part Model Breakdown\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003e85:\u003c\/b\u003e\u003cspan\u003e Stenner 85 Series platform (high-speed gear-driven motor assembly for higher volumetric throughput against pressure).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eM:\u003c\/b\u003e\u003cspan\u003e Mechanical gear motor drive assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eFL:\u003c\/b\u003e\u003cspan\u003e Fixed-rate output (100% duty cycle when energized; flow throttling managed externally by automation controller pulse\/relay cycles).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003e5:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"3\"\u003e#5 Santoprene Pump Tube\u003c\/b\u003e\u003cspan\u003e (rated for high-pressure service up to 100 PSI).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\"\u003eA:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"3\"\u003e120V AC, 60 Hz\u003c\/b\u003e\u003cspan\u003e electrical power specification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,0\"\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"3\"\u003e3\/8\" Outer Diameter (OD)\u003c\/b\u003e\u003cspan\u003e suction and discharge connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,6,0\"\u003e\u003cb data-path-to-node=\"4,6,0\" data-index-in-node=\"0\"\u003eS:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,6,0\" data-index-in-node=\"3\"\u003eSantoprene\u003c\/b\u003e\u003cspan\u003e tube material (standard chemical-grade elastomer for chlorine,\u003c\/span\u003e\u003cspan\u003e acids,\u003c\/span\u003e\u003cspan\u003e and basic pool chemicals).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,7,0\"\u003e\u003cb data-path-to-node=\"4,7,0\" data-index-in-node=\"0\"\u003eU:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"4,7,0\" data-index-in-node=\"3\"\u003eUV-resistant white\u003c\/b\u003e\u003cspan\u003e polyethylene tubing included.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,8,0\"\u003e\u003cb data-path-to-node=\"4,8,0\" data-index-in-node=\"0\"\u003eAA:\u003c\/b\u003e\u003cspan\u003e Standard commercial packaging configuration with complete accessory kit (tubing,\u003c\/span\u003e\u003cspan\u003e injection check valve,\u003c\/span\u003e\u003cspan\u003e weighted suction strainer,\u003c\/span\u003e\u003cspan\u003e and mounting bracket).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eMechanical Architecture \u0026amp; High-Pressure Operation\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eReinforced High-Pressure Roller Drive:\u003c\/b\u003e\u003cspan\u003e Unlike the 25 PSI variants,\u003c\/span\u003e\u003cspan\u003e the 85 Series high-pressure roller assembly is calibrated to maintain tube pinch occlusion against up to \u003c\/span\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"172\"\u003e100 PSI (6.9 bar)\u003c\/b\u003e\u003cspan\u003e of hydrostatic backpressure,\u003c\/span\u003e\u003cspan\u003e preventing pressurized pool water from pushing back into the chemical reservoir.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eContinuous Peristaltic Positive Displacement:\u003c\/b\u003e\u003cspan\u003e Three-roller planetary gear carrier continuously traps fluid inside the Santoprene pump tube.\u003c\/span\u003e\u003cspan\u003e Fluid movement is strictly positive displacement—preventing siphoning without requiring external spring-loaded backpressure valves,\u003c\/span\u003e\u003cspan\u003e and maintaining a self-priming suction lift up to \u003c\/span\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"322\"\u003e25 vertical feet\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eVapor Lock \u0026amp; Gas Handling:\u003c\/b\u003e\u003cspan\u003e Bypasses the gas-binding issues common to electronic diaphragm pumps.\u003c\/span\u003e\u003cspan\u003e Dissolved off-gassing oxygen from liquid bleach (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"O_2\" data-index-in-node=\"146\"\u003e$O_2$\u003c\/span\u003e\u003cspan\u003e) and fuming hydrochloric acid vapors (\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"HCl\" data-index-in-node=\"188\"\u003e$HCl$\u003c\/span\u003e\u003cspan\u003e) pass through the peristaltic tube without disrupting prime.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eComplete Isolation:\u003c\/b\u003e\u003cspan\u003e Wetted chemistry contacts only the inner wall of the Santoprene tube,\u003c\/span\u003e\u003cspan\u003e polyethylene feed line,\u003c\/span\u003e\u003cspan\u003e and duckbill injection check valve,\u003c\/span\u003e\u003cspan\u003e shielding motor windings and drive gears from chemical corrosion.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eOutput Capacity:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"17\"\u003e40.0 GPD\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 1.\u003c\/span\u003e\u003cspan\u003e67 GPH \/ 63.\u003c\/span\u003e\u003cspan\u003e1 mL\/min \/ 151.\u003c\/span\u003e\u003cspan\u003e4 L\/day) at 100 PSI.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eMaximum Discharge Pressure:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"28\"\u003e100 PSI\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 6.\u003c\/span\u003e\u003cspan\u003e89 bar).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eElectrical Service:\u003c\/b\u003e\u003cspan\u003e 120V AC,\u003c\/span\u003e\u003cspan\u003e 60 Hz,\u003c\/span\u003e\u003cspan\u003e 1-Phase,\u003c\/span\u003e\u003cspan\u003e 1.\u003c\/span\u003e\u003cspan\u003e7 A (shaded-pole gear motor with automatic thermal overload protection).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eTurndown Ratio:\u003c\/b\u003e\u003cspan\u003e Fixed output (100% capacity when powered); runtime modulated via dry-contact or powered relay outputs from Pool Link 500\/1000 controllers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-path-to-node=\"10,4,0\" data-index-in-node=\"0\"\u003ePump Tube Assembly:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cb data-path-to-node=\"10,4,0\" data-index-in-node=\"20\"\u003e#5 High-Pressure Santoprene Tube\u003c\/b\u003e\u003cspan\u003e (Part No.\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ccode data-path-to-node=\"10,4,0\" data-index-in-node=\"63\"\u003eMCCP205\u003c\/code\u003e\u003cspan\u003e \/ \u003c\/span\u003e\u003ccode data-path-to-node=\"10,4,0\" data-index-in-node=\"73\"\u003eUCCPM05\u003c\/code\u003e\u003cspan\u003e).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-path-to-node=\"10,5,0\" data-index-in-node=\"0\"\u003eSuction \/ Discharge Plumbing:\u003c\/b\u003e\u003cspan\u003e 3\/8\" OD UV-resistant white opaque polyethylene tubing with compression nut and ferrule fittings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-path-to-node=\"10,6,0\" data-index-in-node=\"0\"\u003eSuction Lift:\u003c\/b\u003e\u003cspan\u003e Up to 25 ft (approx.\u003c\/span\u003e\u003cspan\u003e 7.\u003c\/span\u003e\u003cspan\u003e6 m) vertical water lift.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-path-to-node=\"10,7,0\" data-index-in-node=\"0\"\u003eFluid Operating Temperature Limits:\u003c\/b\u003e\u003cspan class=\"\"\u003e Up to 104°F (40°C); max ambient air temperature 104°F (40°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"12\" class=\"\"\u003eTube Output Comparison (85 Series @ 100 PSI)\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"13\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTube Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGPD @ 100 PSI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGPH @ 100 PSI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003emL\/min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Chemical Service\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,1,0,0\"\u003e\u003cb data-path-to-node=\"13,1,0,0\" data-index-in-node=\"0\"\u003e#1\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,1,1,0\"\u003e4.0\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,1,2,0\"\u003e0.17\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,1,3,0\"\u003e6.3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,1,4,0\"\u003eTrace coagulants \/ small spas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,2,0,0\"\u003e\u003cb data-path-to-node=\"13,2,0,0\" data-index-in-node=\"0\"\u003e#2\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,2,1,0\"\u003e10.0\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,2,2,0\"\u003e0.42\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,2,3,0\"\u003e15.8\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,2,4,0\"\u003eAcid feed \/ medium commercial pools\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,3,0,0\"\u003e\u003cb data-path-to-node=\"13,3,0,0\" data-index-in-node=\"0\"\u003e#7\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,3,1,0\"\u003e17.0\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,3,2,0\"\u003e0.71\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,3,3,0\"\u003e26.8\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,3,4,0\"\u003eChlorine feed \/ high-demand pools\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,4,0,0\"\u003e\u003cb data-path-to-node=\"13,4,0,0\" data-index-in-node=\"0\"\u003e#5 (85MFL5)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,4,1,0\"\u003e\u003cb data-path-to-node=\"13,4,1,0\" data-index-in-node=\"0\"\u003e40.0\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,4,2,0\"\u003e\u003cb data-path-to-node=\"13,4,2,0\" data-index-in-node=\"0\"\u003e1.67\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,4,3,0\"\u003e\u003cb data-path-to-node=\"13,4,3,0\" data-index-in-node=\"0\"\u003e63.1\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"13,4,4,0\"\u003eHigh-volume primary chlorine \/ acid bulk feed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"15\"\u003eMaintenance \u0026amp; Service Wear Parts\u003c\/h3\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"0\"\u003eSantoprene Tube Service Interval:\u003c\/b\u003e\u003cspan\u003e Replace every \u003c\/span\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"48\"\u003e500 to 1,000 run hours\u003c\/b\u003e\u003cspan\u003e (or seasonally every 4 to 6 months in 24\/7 commercial operations).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003e\u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"0\"\u003eRoller Assembly Lubrication:\u003c\/b\u003e\u003cspan\u003e Apply Stenner silicone lubricant to the inner pump head housing and roller wheels during each tube change to prevent friction wear.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003e\u003cb data-path-to-node=\"16,2,0\" data-index-in-node=\"0\"\u003eDuckbill Injection Check Valve:\u003c\/b\u003e\u003cspan\u003e Inspect annually for calcification,\u003c\/span\u003e\u003cspan\u003e swelling,\u003c\/span\u003e\u003cspan\u003e or hardening.\u003c\/span\u003e\u003cspan\u003e Install the injection quill directly into the center of the recirculating pipe line to prevent acid pitting along the pipe wall.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"18\"\u003eWeight and Logistics Profile\u003c\/h3\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"0\"\u003eNet Unit Weight:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"31\"\u003e7.8 to 8.5 pounds\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 3.\u003c\/span\u003e\u003cspan\u003e54 to 3.\u003c\/span\u003e\u003cspan\u003e86 kg).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,1,0\"\u003e\u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"0\"\u003ePhysical Footprint:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"34\"\u003e10.6\" L × 5.3\" W × 6.0\" H\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 26.\u003c\/span\u003e\u003cspan\u003e9 cm × 13.\u003c\/span\u003e\u003cspan\u003e5 cm × 15.\u003c\/span\u003e\u003cspan\u003e2 cm).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,2,0\"\u003e\u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"0\"\u003ePackaged Shipping Carton:\u003c\/b\u003e\u003cspan\u003e Heavy-duty parcel box measuring approximately \u003c\/span\u003e\u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"72\"\u003e14\" L × 10\" W × 9\" H\u003c\/b\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,3,0\"\u003e\u003cb data-path-to-node=\"19,3,0\" data-index-in-node=\"0\"\u003ePackaged Shipping Weight:\u003c\/b\u003e\u003cspan\u003e Approximately \u003c\/span\u003e\u003cb data-path-to-node=\"19,3,0\" data-index-in-node=\"40\"\u003e10.2 to 11.2 pounds\u003c\/b\u003e\u003cspan\u003e (approx.\u003c\/span\u003e\u003cspan\u003e 4.\u003c\/span\u003e\u003cspan\u003e63 to 5.\u003c\/span\u003e\u003cspan\u003e08 kg),\u003c\/span\u003e\u003cspan\u003e complete with accessory kit:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"19,3,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,3,1,0,0\"\u003e\u003cspan\u003e20-foot roll of 3\/8\" White UV-resistant PE tubing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,3,1,1,0\"\u003e\u003cspan\u003eWeighted ceramic suction strainer \/ foot assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,3,1,2,0\"\u003e\u003cspan\u003e1\/4\" or 1\/2\" NPT injection fitting with duckbill check valve.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,3,1,3,0\"\u003e\u003cspan\u003eWall-mount steel bracket,\u003c\/span\u003e\u003cspan\u003e spare tube,\u003c\/span\u003e\u003cspan\u003e and quick-latch clips.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,4,0\"\u003e\u003cb data-path-to-node=\"19,4,0\" data-index-in-node=\"0\"\u003eLogistics Handling:\u003c\/b\u003e\u003cspan\u003e Ships via standard small parcel carriers (UPS,\u003c\/span\u003e\u003cspan\u003e FedEx,\u003c\/span\u003e\u003cspan\u003e USPS).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Commercial Pool and Spa Supplies","offers":[{"title":"Default Title","offer_id":68029949804655,"sku":"85MFL5A3SUAA","price":1036.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/3785\/3807\/files\/51FkrpzvTYL.jpg?v=1793116520","url":"https:\/\/commercialpoolandspasupplies.com\/products\/stenner-85mp5-pump-fx-25psi-85gpd-120v-60hz-3-8w","provider":"Commercial Pool and Spa Supplies ","version":"1.0","type":"link"}