Coates Electric Pool Heater, 12kw 208V Three Phase

Coates Electric Pool Heater, 12kw 208V Three Phase

SKU:32012CE

Regular price $5,864.00
Regular price Sale price $5,864.00
Sale Sold out
Shipping calculated at checkout.
Quantity

The Coates 12kW 208V Three-Phase Electric Pool & Spa Heater (Model 32012CE / 32012CPH) is a commercial-grade inline immersion water heater engineered for commercial hospitality spas, municipal plunge pools, health club hydrotherapy tanks, and athletic training facilities operating on a standard 208V 3-phase/4-wire commercial electrical network.

By distributing the 12kW heating load across three ungrounded phase conductors, the current draw per line is reduced by approximately 42% compared to single-phase equivalents, minimizing line losses, wire gauge requirements, and electrical panel congestion.

Electrical & Heating Performance

  • Model Designation: Coates 32012CE / 32012CPH series (Prefix 320 designates 3-Phase, 208V).

  • Heating Capacity: 12 kW (12,000 Watts).

  • Thermal Output: 40,946 BTU/hr ($12\text{ kW} \times 3,412.142\text{ BTU/kWh}$).

  • Operating Voltage: 208V AC, Three-Phase (3Ø), 3-pole / 3-wire plus ground (or 4-wire Wye), 60 Hz.

  • Full Load Amperage (FLA): 33.3 Amps

    $$\text{FLA} = \frac{12,000\text{ W}}{208\text{ V} \times \sqrt{3}} = \frac{12,000}{360.26} \approx 33.31\text{ A}$$
  • Overcurrent Protection (Breaker Sizing): Requires a dedicated 3-pole 45-Amp or 50-Amp circuit breaker conforming to NEC 125% continuous-duty branch requirements ($33.31\text{ A} \times 1.25 = 41.64\text{ A}$ minimum branch rating, standardizing on a 45A or 50A 3-pole breaker).

  • Conductor Sizing: Minimum #8 AWG or #6 AWG THHN/THWN copper conductor (rated 75°C/90°C terminals, subject to conduit run distance and raceway fill derating).

Construction & Safety Architecture

  • Pressure Vessel: Heavy-gauge, welded cylindrical steel/stainless steel pressure vessel treated with a high-temperature internal protective baked lining to resist aggressive water velocities, chemical corrosion, and galvanic erosion.

  • Heating Elements: Commercial screw-plug immersion elements with heavy-duty Incoloy 800/825 or Titanium alloy sheathing, engineered for uniform heat dissipation and resistance to chemical pitting and scale accumulation.

  • Cabinet & Enclosure: NEMA 1 industrial painted heavy-gauge steel enclosure featuring a removable front access panel for wiring terminations, contactor inspection, and terminal torque verification.

  • Integrated Safety Controls:

    • Dual-dial adjustable thermostatic controller calibrated up to 104°F (40°C) for commercial spa compliance.

    • Manual-reset High-Limit safety cutout set to de-energize the magnetic contactor coil at 122°F (50°C).

    • Pressure/flow-interlock switch preventing heating element contactors from pulling in during low-flow, pump loss, or deadhead conditions.

Hydraulic & Plumbing Specifications

  • Plumbing Connections: Standard 1-1/2" NPT female inlet and outlet ports.

  • Flow Rate Parameters:

    • Minimum Flow Rate: 15 to 20 GPM (approx. 57 to 76 LPM) required to trip the flow switch and prevent localized thermal cavitation/boiling.

    • Maximum Flow Rate: 60 to 70 GPM (approx. 227 to 265 LPM); higher circulation filtration loops require an external plumbed bypass manifold.

  • Maximum Working Pressure: 60 PSI (approx. 4.14 bar).

Dimensions, Net Weight & Shipping Weight

  • Unit Dimensions: Approximately 19.5" L × 10.0" W × 14.5" H (approx. 49.5 cm × 25.4 cm × 36.8 cm).

  • Net Unit Weight: Approximately 46 to 52 lbs (approx. 20.9 to 23.6 kg).

  • Packaged Shipping Dimensions: Approximately 22" L × 13" W × 17" H.

  • Packaged Shipping Weight: Approximately 58 to 66 lbs (approx. 26.3 to 29.9 kg) in heavy-gauge corrugated packaging with protective foam inserts.

Estimated Temperature Rise Rates

Pool / Spa Volume Water Weight Approx. Temperature Rise per Hour
500 Gallons ~4,170 lbs 9.8°F / hr
1,000 Gallons ~8,340 lbs 4.9°F / hr
2,500 Gallons ~20,850 lbs 2.0°F / hr
5,000 Gallons ~41,700 lbs 1.0°F / hr

(Calculation: $\text{Rise (°F/hr)} = \frac{40,946\text{ BTU/hr}}{\text{Gallons} \times 8.34\text{ lbs/gal}}$, baseline heat-up rate assuming covered vessel without ambient radiation losses.)