Skip to product information
1 of 1

Commercial Pool and Spa Supplies

Coates Electric Pool Heater, 24kw 600V Three Phase

Coates Electric Pool Heater, 24kw 600V Three Phase

SKU:36024CPH

Regular price $7,540.00
Regular price Sale price $7,540.00
Sale Sold out
Shipping calculated at checkout.
Quantity

The Coates 24kW 600V Three-Phase Electric Pool & Spa Heater (Model 36024CE / 36024CPH) is a commercial-grade inline immersion water heater engineered for high-demand municipal therapy pools, resort spas, swim schools, and institutional aquatic facilities operating on a standard 600V 3-phase distribution network (predominant in Canadian commercial and industrial facilities).

Operating 24kW at 600V three-phase keeps the current draw at just 23.1 Amps, allowing facilities to install a high-output heating system using standard #10 AWG copper conductors and a compact 30A 3-pole 600V circuit breaker.

Electrical & Heating Performance

  • Model Designation: Coates 36024CE / 36024CPH series (360 designates 3-Phase, 600V).

  • Heating Capacity: 24 kW (24,000 Watts).

  • Thermal Output: 81,891 BTU/hr ($24\text{ kW} \times 3,412.142\text{ BTU/kWh}$).

  • Operating Voltage: 600V AC, Three-Phase (3Ø), 3-pole / 3-wire plus ground (or 4-wire Wye), 60 Hz.

  • Full Load Amperage (FLA): 23.1 Amps

    $$\text{FLA} = \frac{24,000\text{ W}}{600\text{ V} \times \sqrt{3}} = \frac{24,000}{1,039.23} \approx 23.09\text{ A}$$
  • Overcurrent Protection (Breaker Sizing): Requires a dedicated 3-pole 30-Amp circuit breaker (600V-rated) conforming to continuous-duty branch loading requirements ($23.09\text{ A} \times 1.25 = 28.87\text{ A}$ minimum branch rating, standardizing on a 30A 600V 3-pole breaker).

  • Conductor Sizing: Minimum #10 AWG copper conductor (rated 600V, 75°C/90°C THHN/THWN/RW90, adjusted for ambient derating and raceway fill).

Construction & Safety Architecture

  • Pressure Vessel: Heavy-gauge, welded cylindrical steel/stainless steel pressure chamber treated internally with a baked corrosion-resistant protective coating to endure continuous commercial water flow and aggressive sanitizing chemicals.

  • Heating Elements: Screw-plug commercial immersion elements rated for 600V operation, sheathed in premium Incoloy 800/825 or Titanium alloy to resist chemical pitting, scaling, and high thermal stress.

  • Cabinet & Enclosure: NEMA 1 industrial painted heavy-gauge steel cabinet with a removable front access panel for terminal inspections, 600V-rated magnetic contactor servicing, and field wire terminations.

  • Internal Control Circuit: Factory-installed step-down control transformer (600V primary to 120V/24V secondary) powering the thermostatic control circuit and safety interlocks.

  • Integrated Safety Controls:

    • Dual-dial adjustable thermostatic controller calibrated up to 104°F (40°C) for commercial spa compliance.

    • Manual-reset High-Limit safety cutout set to de-energize the magnetic contactor control circuit at 122°F (50°C).

    • Pressure/flow-interlock switch preventing heating element contactors from pulling in during low-flow, pump loss, or deadhead conditions.

Hydraulic & Plumbing Specifications

  • Plumbing Connections: Standard 1-1/2" NPT female inlet and outlet ports (typically adapted via Schedule 80 unions into 2" or 2-1/2" CPVC headers).

  • Flow Rate Parameters:

    • Minimum Flow Rate: 20 GPM (approx. 76 LPM) required to trip the safety flow switch and prevent localized thermal cavitation.

    • Maximum Flow Rate: 60 to 70 GPM (approx. 227 to 265 LPM); filtration loops operating at higher GPM mandate an external plumbed bypass manifold.

  • Maximum Working Pressure: 60 PSI (approx. 4.14 bar).

Dimensions, Net Weight & Shipping Weight

  • Unit Dimensions: Approximately 24.0" L × 12.0" W × 16.5" H (approx. 61.0 cm × 30.5 cm × 41.9 cm).

  • Net Unit Weight: Approximately 62 to 70 lbs (approx. 28.1 to 31.8 kg).

  • Packaged Shipping Dimensions: Approximately 26" L × 15" W × 19" H.

  • Packaged Shipping Weight: Approximately 75 to 84 lbs (approx. 34.0 to 38.1 kg) in heavy-duty reinforced corrugated carton packaging with dense molded foam protection.

Estimated Temperature Rise Rates

Pool / Spa Volume Water Weight Approx. Temperature Rise per Hour
500 Gallons ~4,170 lbs 19.6°F / hr
1,000 Gallons ~8,340 lbs 9.8°F / hr
2,500 Gallons ~20,850 lbs 3.9°F / hr
5,000 Gallons ~41,700 lbs 2.0°F / hr
10,000 Gallons ~83,400 lbs 1.0°F / hr

(Calculation: $\text{Rise (°F/hr)} = \frac{81,891\text{ BTU/hr}}{\text{Gallons} \times 8.34\text{ lbs/gal}}$, baseline heat-up rate assuming covered vessel without ambient radiation losses.)

View full details