The Coates 30kW 600V Three-Phase Electric Pool & Spa Heater (Model 36030CE / 36030CPH) is a high-output, commercial inline immersion water heater designed for high-occupancy commercial spas, municipal therapy pools, resort aquatic complexes, and swim schools operating on a standard 600V 3-phase distribution network (predominant across Canadian commercial, institutional, and industrial facilities).
Distributing 30kW over a 600V 3-phase line keeps the current draw at just 28.9 Amps, allowing high-recovery commercial heating performance with compact branch circuits and standard #8 AWG wiring.
Electrical & Heating Performance
-
Model Designation: Coates 36030CE / 36030CPH series (
360designates 3-Phase, 600V). -
Heating Capacity: 30 kW (30,000 Watts).
-
Thermal Output: 102,364 BTU/hr ($30\text{ kW} \times 3,412.142\text{ BTU/kWh}$).
-
Operating Voltage: 600V AC, Three-Phase (3Ø), 3-pole / 3-wire plus ground (or 4-wire Wye), 60 Hz.
-
Full Load Amperage (FLA): 28.9 Amps
$$\text{FLA} = \frac{30,000\text{ W}}{600\text{ V} \times \sqrt{3}} = \frac{30,000}{1,039.23} \approx 28.87\text{ A}$$ -
Overcurrent Protection (Breaker Sizing): Requires a dedicated 3-pole 40-Amp circuit breaker (600V-rated) conforming to continuous-duty branch loading requirements ($28.87\text{ A} \times 1.25 = 36.09\text{ A}$ minimum branch rating, standardizing on a 40A 600V 3-pole breaker).
-
Conductor Sizing: Minimum #8 AWG copper conductor (rated 600V, 75°C/90°C THHN/THWN/RW90, adjusted for ambient derating and run length).
Construction & Safety Architecture
-
Pressure Vessel: Heavy-gauge, welded cylindrical steel/stainless steel pressure vessel treated internally with a baked corrosion-resistant protective coating to endure continuous commercial water velocity and aggressive sanitizing chemicals.
-
Heating Elements: Screw-plug commercial immersion elements rated for 600V operation, sheathed in premium Incoloy 800/825 or Titanium alloy to resist pitting, scale buildup, and high thermal stress.
-
Cabinet & Enclosure: NEMA 1 industrial painted heavy-gauge steel cabinet with a removable front access panel for terminal inspections, 600V-rated magnetic contactor servicing, and field wire terminations.
-
Internal Control Circuit: Factory-installed step-down control transformer (600V primary to 120V/24V secondary) powering the thermostatic control circuit and safety interlocks.
-
Integrated Safety Controls:
-
Dual-dial adjustable thermostatic controller calibrated up to 104°F (40°C) for commercial spa compliance.
-
Manual-reset High-Limit safety cutout set to de-energize the magnetic contactor control circuit at 122°F (50°C).
-
Pressure/flow-interlock switch preventing heating element contactors from pulling in during low-flow, pump loss, or deadhead conditions.
-
Hydraulic & Plumbing Specifications
-
Plumbing Connections: Standard 1-1/2" NPT female inlet and outlet ports (typically adapted via Schedule 80 unions into 2" or 2-1/2" CPVC headers).
-
Flow Rate Parameters:
-
Minimum Flow Rate: 20 GPM (approx. 76 LPM) required to trip the safety flow switch and prevent localized thermal cavitation.
-
Maximum Flow Rate: 60 to 70 GPM (approx. 227 to 265 LPM); filtration loops operating at higher GPM mandate an external plumbed bypass manifold.
-
-
Maximum Working Pressure: 60 PSI (approx. 4.14 bar).
Dimensions, Net Weight & Shipping Weight
-
Unit Dimensions: Approximately 24.0" L × 12.0" W × 16.5" H (approx. 61.0 cm × 30.5 cm × 41.9 cm).
-
Net Unit Weight: Approximately 68 to 76 lbs (approx. 30.8 to 34.5 kg).
-
Packaged Shipping Dimensions: Approximately 26" L × 15" W × 19" H.
-
Packaged Shipping Weight: Approximately 82 to 92 lbs (approx. 37.2 to 41.7 kg) in heavy-duty reinforced corrugated carton packaging with dense molded foam protection.
Estimated Temperature Rise Rates
| Pool / Spa Volume | Water Weight | Approx. Temperature Rise per Hour |
| 500 Gallons | ~4,170 lbs | 24.5°F / hr |
| 1,000 Gallons | ~8,340 lbs | 12.3°F / hr |
| 2,500 Gallons | ~20,850 lbs | 4.9°F / hr |
| 5,000 Gallons | ~41,700 lbs | 2.5°F / hr |
| 10,000 Gallons | ~83,400 lbs | 1.2°F / hr |
(Calculation: $\text{Rise (°F/hr)} = \frac{102,364\text{ BTU/hr}}{\text{Gallons} \times 8.34\text{ lbs/gal}}$, baseline heat-up rate assuming covered vessel without ambient radiation losses.)