Commercial Pool and Spa Supplies
Coates Electric Pool Heater, 36kw 208V Three Phase, Salt Water Application
Coates Electric Pool Heater, 36kw 208V Three Phase, Salt Water Application
SKU:32036PHS-CN
Couldn't load pickup availability
The Coates 36kW 208V Three-Phase Electric Pool & Spa Heater for Salt Water Applications (Model 32036CES / 32036CPHS — featuring the "S" saltwater/corrosion-resistant package) is a heavy-duty inline immersion heater designed for commercial hydrotherapy pools, municipal swim schools, resort aquatic complexes, and athletic training tanks operating with electrolytic salt chlorine generation systems (typically 2,500 to 4,500+ ppm TDS/NaCl) on a standard 208V 3-phase/4-wire electrical distribution network.
Operating 36kW across 208V 3-phase draws 99.9 Amps per phase (compared to 150 Amps on single-phase 240V). The factory saltwater configuration provides upgraded metallurgy and protective tank barrier coatings to withstand aggressive saline electrolytes, preventing chloride pitting and stress corrosion cracking.
Electrical & Heating Performance
-
Model Designation: Coates 32036CES / 32036CPHS series (
320designates 3-Phase 208V; suffix designates Saltwater/Titanium package). -
Heating Capacity: 36 kW (36,000 Watts).
-
Thermal Output: 122,837 BTU/hr ($36\text{ kW} \times 3,412.142\text{ BTU/kWh}$).
-
Operating Voltage: 208V AC, Three-Phase (3Ø), 3-pole / 3-wire plus ground (or 4-wire Wye), 60 Hz.
-
Full Load Amperage (FLA): 99.9 Amps
$$\text{FLA} = \frac{36,000\text{ W}}{208\text{ V} \times \sqrt{3}} = \frac{36,000}{360.26} \approx 99.93\text{ A} \rightarrow 99.9\text{ A}$$ -
Overcurrent Protection (Breaker Sizing): Requires a dedicated 3-pole 125-Amp circuit breaker conforming to NEC/CEC 125% continuous-duty loading standards ($99.93\text{ A} \times 1.25 = 124.91\text{ A}$ minimum branch rating, standardizing on a 125A 3-pole breaker).
-
Conductor Sizing: Minimum #1 AWG or #1/0 AWG THHN/THWN copper conductor (rated 75°C/90°C terminals, adjusted for ambient derating and raceway distance).
Salt Water Construction & Metallurgy Upgrades
-
Titanium / Incoloy 825 Sheathed Elements: Standard immersion elements are replaced with Titanium or high-molybdenum/nickel Incoloy 825 sheathing to prevent chloride-induced stress corrosion cracking (SCC), scale accumulation, and localized pitting from dissolved sodium chloride.
-
Passivated / Barrier-Coated Pressure Vessel: Cylindrical pressure chamber fabricated from heavy-gauge 316L stainless steel or carbon steel lined with a specialized baked phenolic epoxy/fluoropolymer protective barrier, isolating the tank substrate from saline electrolytic degradation.
-
Sacrificial Cathodic Protection: Equipped with an accessible sacrificial zinc or magnesium anode plug port to absorb galvanic action and mitigate stray current erosion in the salt plumbing loop.
-
Corrosion-Inhibited Cabinet: Heavy-gauge NEMA 1 industrial painted enclosure finished with an anti-corrosion powder coating to prevent cabinet degradation in high-humidity, salt-vapor mechanical rooms.
Construction & Safety Architecture
-
Cabinet & Enclosure: NEMA 1 industrial painted steel cabinet with a removable front panel for terminal inspections, heavy-duty staged 3-pole magnetic contactor servicing, and field wire terminations.
-
Integrated Safety Controls:
-
Dual-dial adjustable thermostatic controller calibrated up to 104°F (40°C) for commercial spa compliance.
-
Manual-reset High-Limit safety cutout set to de-energize the magnetic contactor control circuit at 122°F (50°C).
-
Pressure/flow-interlock switch preventing heating element contactors from pulling in during low-flow, pump loss, or deadhead conditions.
-
Hydraulic & Plumbing Specifications
-
Plumbing Connections: Standard 1-1/2" NPT female inlet and outlet ports (adapted via Schedule 80 CPVC unions into 2" or 2-1/2" headers).
-
Equipment Sequencing in Salt Systems: Must always be installed upstream of the electrolytic chlorine generator cell (separated by an inline corrosion-resistant check valve) to prevent hyper-concentrated chlorine gas or acidic pockets from pooling inside the heater vessel during pump shutdowns.
-
Flow Rate Parameters:
-
Minimum Flow Rate: 20 to 25 GPM (approx. 76 to 95 LPM) required to trip the safety flow switch and prevent localized thermal cavitation.
-
Maximum Flow Rate: 60 to 70 GPM (approx. 227 to 265 LPM); filtration loops operating at higher GPM mandate an external plumbed bypass manifold.
-
-
Maximum Working Pressure: 60 PSI (approx. 4.14 bar).
Dimensions, Net Weight & Shipping Weight
-
Unit Dimensions: Approximately 24.0" L × 12.0" W × 16.5" H (approx. 61.0 cm × 30.5 cm × 41.9 cm).
-
Net Unit Weight: Approximately 74 to 82 lbs (approx. 33.6 to 37.2 kg).
-
Packaged Shipping Dimensions: Approximately 26" L × 15" W × 19" H.
-
Packaged Shipping Weight: Approximately 88 to 98 lbs (approx. 39.9 to 44.5 kg) in heavy-duty reinforced corrugated carton packaging with dense molded foam protection.
Estimated Temperature Rise Rates
| Pool / Spa Volume | Water Weight | Approx. Temperature Rise per Hour |
| 500 Gallons | ~4,170 lbs | 29.5°F / hr |
| 1,000 Gallons | ~8,340 lbs | 14.7°F / hr |
| 2,500 Gallons | ~20,850 lbs | 5.9°F / hr |
| 5,000 Gallons | ~41,700 lbs | 2.9°F / hr |
| 10,000 Gallons | ~83,400 lbs | 1.5°F / hr |
| 15,000 Gallons | ~125,100 lbs | 1.0°F / hr |
(Calculation: $\text{Rise (°F/hr)} = \frac{122,837\text{ BTU/hr}}{\text{Gallons} \times 8.34\text{ lbs/gal}}$, baseline heat-up rate assuming covered vessel without ambient radiation losses.)