Commercial Pool and Spa Supplies
Coates Electric Pool Heater, 45kw 600V Three Phase
Coates Electric Pool Heater, 45kw 600V Three Phase
SKU:36045PHS
Couldn't load pickup availability
The Coates 45kW 600V Three-Phase Electric Pool & Spa Heater (Model 36045CE / 36045CPH) is a commercial-grade inline immersion water heater engineered for high-demand municipal therapy pools, resort aquatic complexes, swim schools, and institutional athletic training tanks operating on a standard 600V 3-phase electrical service (predominantly found in Canadian commercial and industrial facilities).
Operating 45kW at 600V three-phase keeps the continuous current draw at just 43.3 Amps, allowing commercial facilities to achieve heavy thermal recovery rates while utilizing compact branch breakers and standard #6 AWG copper conductors.
Electrical & Heating Performance
-
Model Designation: Coates 36045CE / 36045CPH series (
360designates 3-Phase, 600V). -
Heating Capacity: 45 kW (45,000 Watts).
-
Thermal Output: 153,546 BTU/hr ($45\text{ kW} \times 3,412.142\text{ BTU/kWh}$).
-
Operating Voltage: 600V AC, Three-Phase (3Ø), 3-pole / 3-wire plus ground (or 4-wire Wye), 60 Hz.
-
Full Load Amperage (FLA): 43.3 Amps
$$\text{FLA} = \frac{45,000\text{ W}}{600\text{ V} \times \sqrt{3}} = \frac{45,000}{1,039.23} \approx 43.30\text{ A}$$ -
Overcurrent Protection (Breaker Sizing): Requires a dedicated 3-pole 60-Amp circuit breaker (600V-rated) conforming to continuous-duty branch loading requirements ($43.30\text{ A} \times 1.25 = 54.13\text{ A}$ minimum branch rating, standardizing on a 60A 600V 3-pole breaker).
-
Conductor Sizing: Minimum #6 AWG copper conductor (rated 600V, 75°C/90°C THHN/THWN/RW90, adjusted for ambient derating and run length).
Construction & Safety Architecture
-
Pressure Vessel: Heavy-gauge, welded cylindrical steel/stainless steel pressure vessel treated internally with a baked corrosion-resistant protective coating to endure continuous commercial water velocity and aggressive sanitizing chemicals.
-
Heating Elements: Screw-plug commercial immersion elements rated for 600V operation, sheathed in premium Incoloy 800/825 or Titanium alloy to resist pitting, scale accumulation, and high thermal stress.
-
Cabinet & Enclosure: NEMA 1 industrial painted heavy-gauge steel cabinet with a removable front access panel for terminal inspections, 600V-rated magnetic contactor servicing, and field wire terminations.
-
Internal Control Circuit: Factory-installed step-down control transformer (600V primary to 120V/24V secondary) powering the thermostatic control circuit and safety interlocks.
-
Integrated Safety Controls:
-
Dual-dial adjustable thermostatic controller calibrated up to 104°F (40°C) for commercial spa compliance.
-
Manual-reset High-Limit safety cutout set to de-energize the magnetic contactor control circuit at 122°F (50°C).
-
Pressure/flow-interlock switch preventing heating element contactors from pulling in during low-flow, pump loss, or deadhead conditions.
-
Hydraulic & Plumbing Specifications
-
Plumbing Connections: Standard 1-1/2" NPT female inlet and outlet ports (typically adapted via Schedule 80 unions into 2" or 2-1/2" CPVC headers).
-
Flow Rate Parameters:
-
Minimum Flow Rate: 25 to 30 GPM (approx. 95 to 114 LPM) required to trip the safety flow switch and prevent localized thermal cavitation.
-
Maximum Flow Rate: 60 to 70 GPM (approx. 227 to 265 LPM); filtration loops operating at higher GPM mandate an external plumbed bypass manifold.
-
-
Maximum Working Pressure: 60 PSI (approx. 4.14 bar).
Dimensions, Net Weight & Shipping Weight
-
Unit Dimensions: Approximately 24.0" L × 12.0" W × 16.5" H (approx. 61.0 cm × 30.5 cm × 41.9 cm).
-
Net Unit Weight: Approximately 82 to 90 lbs (approx. 37.2 to 40.8 kg).
-
Packaged Shipping Dimensions: Approximately 26" L × 15" W × 19" H.
-
Packaged Shipping Weight: Approximately 96 to 108 lbs (approx. 43.5 to 49.0 kg) in heavy-duty reinforced corrugated carton packaging with dense molded foam protection.
Estimated Temperature Rise Rates
| Pool / Spa Volume | Water Weight | Approx. Temperature Rise per Hour |
| 500 Gallons | ~4,170 lbs | 36.8°F / hr |
| 1,000 Gallons | ~8,340 lbs | 18.4°F / hr |
| 2,500 Gallons | ~20,850 lbs | 7.4°F / hr |
| 5,000 Gallons | ~41,700 lbs | 3.7°F / hr |
| 10,000 Gallons | ~83,400 lbs | 1.8°F / hr |
| 15,000 Gallons | ~125,100 lbs | 1.2°F / hr |
(Calculation: $\text{Rise (°F/hr)} = \frac{153,546\text{ BTU/hr}}{\text{Gallons} \times 8.34\text{ lbs/gal}}$, baseline heat-up rate assuming covered vessel without ambient radiation losses.)