Skip to product information
1 of 1

Commercial Pool and Spa Supplies

Coates Electric Pool Heater, 45kw 600V Three Phase, Salt Water Application

Coates Electric Pool Heater, 45kw 600V Three Phase, Salt Water Application

SKU:36045PHS-CN

Regular price $16,514.00
Regular price Sale price $16,514.00
Sale Sold out
Shipping calculated at checkout.
Quantity

The Coates 45kW 600V Three-Phase Electric Pool & Spa Heater for Salt Water Applications (Model 36045CES / 36045CPHS — featuring the "S" saltwater/corrosion-resistant package) is a heavy-duty inline immersion heater engineered for municipal therapy pools, resort aquatic complexes, commercial swim schools, and athletic recovery facilities operating with electrolytic salt chlorine generation systems (typically 2,500 to 4,500+ ppm TDS/NaCl) on a standard Canadian 600V 3-phase/3-wire or 4-wire electrical distribution network.

Operating 45kW across a 600V 3-phase supply draws 43.3 Amps per phase (compared to 124.9 Amps on 208V 3-phase and 187.5 Amps on single-phase 240V). This high-voltage configuration significantly reduces raceway congestion and conductor sizing while the factory saltwater package prevents accelerated galvanic degradation and chloride stress corrosion cracking in high-salinity water.

Electrical & Heating Performance

  • Model Designation: Coates 36045CES / 36045CPHS series (360 designates 3-Phase 600V; suffix designates Saltwater/Titanium package).

  • Heating Capacity: 45 kW (45,000 Watts).

  • Thermal Output: 153,546 BTU/hr ($45\text{ kW} \times 3,412.142\text{ BTU/kWh}$).

  • Operating Voltage: 600V AC, Three-Phase (3Ø), 3-pole / 3-wire plus ground (or 4-wire Wye), 60 Hz.

  • Full Load Amperage (FLA): 43.3 Amps

    $$\text{FLA} = \frac{45,000\text{ W}}{600\text{ V} \times \sqrt{3}} = \frac{45,000}{1,039.23} \approx 43.30\text{ A} \rightarrow 43.3\text{ A}$$
  • Overcurrent Protection (Breaker Sizing): Requires a dedicated 3-pole 60-Amp circuit breaker (600V-rated) conforming to CEC/NEC 125% continuous-duty loading standards ($43.30\text{ A} \times 1.25 = 54.13\text{ A}$ minimum branch rating, standardizing on a 60A 600V 3-pole breaker).

  • Conductor Sizing: Minimum #6 AWG copper conductor (rated 600V, 75°C/90°C THHN/THWN/RW90; adjusted for ambient derating and raceway distance).

Salt Water Construction & Metallurgy Upgrades

  • Titanium / Incoloy 825 Sheathed Elements: Immersion elements are upgraded from standard alloys to Titanium or high-molybdenum/nickel Incoloy 825 sheathing to resist chloride-induced stress corrosion cracking (SCC), scale accumulation, and localized pitting from dissolved sodium chloride and electrolytic chlorination.

  • Passivated / Barrier-Coated Pressure Vessel: Extended cylindrical pressure chamber fabricated from heavy-gauge 316L stainless steel or carbon steel lined with a specialized baked phenolic epoxy/fluoropolymer protective barrier, isolating the tank substrate from saline electrolytic degradation.

  • Sacrificial Cathodic Protection: Equipped with an accessible sacrificial zinc or magnesium anode plug port to absorb galvanic action and mitigate stray current erosion in the salt plumbing loop.

  • Corrosion-Inhibited Cabinet: Heavy-gauge NEMA 1 industrial painted enclosure finished with an anti-corrosion powder coating to prevent cabinet degradation in high-humidity, salt-vapor mechanical rooms.

Construction & Safety Architecture

  • Cabinet & Enclosure: NEMA 1 industrial painted steel cabinet with a removable front panel for terminal inspections, multiple staged 600V-rated 3-pole magnetic contactor servicing, and field wire terminations.

  • Internal Control Circuit: Factory-installed step-down control transformer (600V primary to 120V/24V secondary) powering the thermostatic control circuit and safety interlocks.

  • Integrated Safety Controls:

    • Dual-dial adjustable thermostatic controller calibrated up to 104°F (40°C) for commercial spa compliance.

    • Manual-reset High-Limit safety cutout set to de-energize the magnetic contactor control circuit at 122°F (50°C).

    • Pressure/flow-interlock switch preventing heating element contactors from pulling in during low-flow, pump loss, or deadhead conditions.

Hydraulic & Plumbing Specifications

  • Plumbing Connections: Standard 1-1/2" NPT female inlet and outlet ports (adapted via Schedule 80 CPVC unions into 2" or 2-1/2" headers).

  • Equipment Sequencing in Salt Systems: Must always be installed upstream of the electrolytic chlorine generator cell (separated by an inline corrosion-resistant check valve) to prevent hyper-concentrated chlorine gas or acidic pockets from pooling inside the heater vessel during pump shutdowns.

  • Flow Rate Parameters:

    • Minimum Flow Rate: 25 to 30 GPM (approx. 95 to 114 LPM) required to trip the safety flow switch and prevent localized thermal cavitation across multi-element arrays.

    • Maximum Flow Rate: 60 to 70 GPM (approx. 227 to 265 LPM); filtration loops operating at higher GPM mandate an external plumbed bypass manifold.

  • Maximum Working Pressure: 60 PSI (approx. 4.14 bar).

Dimensions, Net Weight & Shipping Weight

  • Unit Dimensions: Approximately 24.0" L × 12.0" W × 16.5" H (approx. 61.0 cm × 30.5 cm × 41.9 cm).

  • Net Unit Weight: Approximately 82 to 90 lbs (approx. 37.2 to 40.8 kg).

  • Packaged Shipping Dimensions: Approximately 26" L × 15" W × 19" H.

  • Packaged Shipping Weight: Approximately 96 to 108 lbs (approx. 43.5 to 49.0 kg) in heavy-duty reinforced corrugated carton packaging with dense molded foam protection.

Estimated Temperature Rise Rates

Pool / Spa Volume Water Weight Approx. Temperature Rise per Hour
500 Gallons ~4,170 lbs 36.8°F / hr
1,000 Gallons ~8,340 lbs 18.4°F / hr
2,500 Gallons ~20,850 lbs 7.4°F / hr
5,000 Gallons ~41,700 lbs 3.7°F / hr
10,000 Gallons ~83,400 lbs 1.8°F / hr
15,000 Gallons ~125,100 lbs 1.2°F / hr

(Calculation: $\text{Rise (°F/hr)} = \frac{153,546\text{ BTU/hr}}{\text{Gallons} \times 8.34\text{ lbs/gal}}$, baseline heat-up rate assuming covered vessel without ambient radiation losses.)

View full details