Commercial Pool and Spa Supplies
Coates Electric Pool Heater, 54kw 600V Three Phase
Coates Electric Pool Heater, 54kw 600V Three Phase
SKU:36054PHS
Couldn't load pickup availability
The Coates 54kW 600V Three-Phase Electric Pool & Spa Heater (Model 36054CE / 36054CPH) is a commercial-grade inline immersion water heater engineered for large municipal therapy pools, resort aquatic complexes, swim schools, and institutional athletic training tanks operating on a standard 600V 3-phase distribution network (predominant across Canadian commercial, institutional, and industrial facilities).
Operating 54kW at 600V three-phase keeps the current draw at just 52.0 Amps, enabling commercial facilities to achieve massive thermal output while running on a single 3-pole 70A 600V breaker and standard #4 AWG copper conductors.
Electrical & Heating Performance
-
Model Designation: Coates 36054CE / 36054CPH series (
360designates 3-Phase, 600V). -
Heating Capacity: 54 kW (54,000 Watts).
-
Thermal Output: 184,256 BTU/hr ($54\text{ kW} \times 3,412.142\text{ BTU/kWh}$).
-
Operating Voltage: 600V AC, Three-Phase (3Ø), 3-pole / 3-wire plus ground (or 4-wire Wye), 60 Hz.
-
Full Load Amperage (FLA): 52.0 Amps
$$\text{FLA} = \frac{54,000\text{ W}}{600\text{ V} \times \sqrt{3}} = \frac{54,000}{1,039.23} \approx 51.96\text{ A}$$ -
Overcurrent Protection (Breaker Sizing): Requires a dedicated 3-pole 70-Amp circuit breaker (600V-rated) conforming to continuous-duty branch loading requirements ($51.96\text{ A} \times 1.25 = 64.95\text{ A}$ minimum branch rating, standardizing on a 70A 600V 3-pole breaker).
-
Conductor Sizing: Minimum #4 AWG copper conductor (rated 600V, 75°C/90°C THHN/THWN/RW90, adjusted for ambient derating and run length).
Construction & Safety Architecture
-
Pressure Vessel: Heavy-gauge, welded cylindrical steel/stainless steel pressure vessel treated internally with a baked corrosion-resistant protective coating to endure continuous commercial water velocity and aggressive sanitizing chemicals.
-
Heating Elements: Screw-plug commercial immersion elements rated for 600V operation, sheathed in premium Incoloy 800/825 or Titanium alloy to resist pitting, scale accumulation, and high thermal stress.
-
Cabinet & Enclosure: NEMA 1 industrial painted heavy-gauge steel cabinet with a removable front access panel for terminal inspections, 600V-rated magnetic contactor servicing, and field wire terminations.
-
Internal Control Circuit: Factory-installed step-down control transformer (600V primary to 120V/24V secondary) powering the thermostatic control circuit and safety interlocks.
-
Integrated Safety Controls:
-
Dual-dial adjustable thermostatic controller calibrated up to 104°F (40°C) for commercial spa compliance.
-
Manual-reset High-Limit safety cutout set to de-energize the magnetic contactor control circuit at 122°F (50°C).
-
Pressure/flow-interlock switch preventing heating element contactors from pulling in during low-flow, pump loss, or deadhead conditions.
-
Hydraulic & Plumbing Specifications
-
Plumbing Connections: Standard 1-1/2" NPT female inlet and outlet ports (typically adapted via Schedule 80 unions into 2", 2-1/2", or 3" CPVC headers).
-
Flow Rate Parameters:
-
Minimum Flow Rate: 30 GPM (approx. 114 LPM) required to trip the safety flow switch and prevent localized thermal cavitation.
-
Maximum Flow Rate: 60 to 70 GPM (approx. 227 to 265 LPM); filtration loops operating at higher GPM mandate an external plumbed bypass manifold.
-
-
Maximum Working Pressure: 60 PSI (approx. 4.14 bar).
Dimensions, Net Weight & Shipping Weight
-
Unit Dimensions: Approximately 24.0" L × 12.0" W × 16.5" H (approx. 61.0 cm × 30.5 cm × 41.9 cm).
-
Net Unit Weight: Approximately 88 to 96 lbs (approx. 39.9 to 43.5 kg).
-
Packaged Shipping Dimensions: Approximately 26" L × 15" W × 19" H.
-
Packaged Shipping Weight: Approximately 102 to 114 lbs (approx. 46.3 to 51.7 kg) in heavy-duty reinforced corrugated carton packaging with dense molded foam protection.
Estimated Temperature Rise Rates
| Pool / Spa Volume | Water Weight | Approx. Temperature Rise per Hour |
| 500 Gallons | ~4,170 lbs | 44.2°F / hr |
| 1,000 Gallons | ~8,340 lbs | 22.1°F / hr |
| 2,500 Gallons | ~20,850 lbs | 8.8°F / hr |
| 5,000 Gallons | ~41,700 lbs | 4.4°F / hr |
| 10,000 Gallons | ~83,400 lbs | 2.2°F / hr |
| 15,000 Gallons | ~125,100 lbs | 1.5°F / hr |
| 20,000 Gallons | ~166,800 lbs | 1.1°F / hr |
(Calculation: $\text{Rise (°F/hr)} = \frac{184,256\text{ BTU/hr}}{\text{Gallons} \times 8.34\text{ lbs/gal}}$, baseline heat-up rate assuming covered vessel without ambient radiation losses.)